Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6XV1830-0ET10 PROFIBUS Cable

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6XV1830-0ET10.

Exact part6XV1830-0ET10 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6XV1830-0ET10 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6XV1830-0ET10

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6XV1830-0ET10
Product Type
PROFIBUS Cable
Product Family
Other series
Country of Origin
DE
Catalog Category
Communication
Model confirmed for inquiry 6XV1830-0ET10 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens 6XV1830-0ET10 PROFIBUS Type A Bus Cable 100M — Every Minute of Downtime Costs You Money. We Ship Today.

Your PROFIBUS network just dropped. The HMI is showing bus fault. The S7-400 DP master is throwing OB86 — station failure. You’ve already isolated the segment, pulled the suspect cable, and confirmed it with a PROFIBUS tester: the shield is broken, impedance is out of spec, and the line is dead. You need a 6XV1830-0ET10 on-site before the next shift starts. That’s exactly what we stock for.

At siemensplc.com, we maintain ready inventory of the Siemens 6XV1830-0ET10 specifically because fieldbus cable failures don’t schedule themselves. This is a 100-meter pre-cut length of genuine Simatic Net Type A PROFIBUS bus cable — the IEC 61158 / EN 50170 reference standard for RS-485 PROFIBUS DP installations. Double-shielded, violet-jacketed, impedance-controlled to 135–165 Ω. No substitutes. No grey-market stock. Shipped from Xiamen with DHL/FedEx Express tracking the same business day for confirmed orders.

⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number 6XV1830-0ET10 ✅ Ready to Ship
Series Simatic Net ✅ Genuine OEM
Cable Type PROFIBUS Type A, RS-485
Length 100 m (pre-cut)
Characteristic Impedance 135–165 Ω (3–20 MHz)
Capacitance ≤ 30 pF/m
Loop Resistance ≤ 110 Ω/km
Conductor 0.64 mm / 0.34 mm² (AWG 22)
Shielding Braided copper + foil (double)
Jacket Color Violet (PROFIBUS standard)
Outer Diameter ~8.0 mm
Max Baud Rate 12 Mbit/s
Operating Temp -20°C to +60°C (fixed)
Standards IEC 61158, EN 50170, UL/CSA
Origin Germany
Dispatch Same-day (confirmed orders) ✅ Xiamen Stock

Troubleshooting & Replacement Tips

Ten years of field work teaches you that most PROFIBUS cable failures fall into three categories. Here’s how to handle each one on the 6XV1830-0ET10 replacement job:

1. OB86 / Station Failure — Partial Segment Loss
Before you pull the cable, use a PROFIBUS tester (e.g., ProfiTrace, Softing PB-T3) to confirm which segment the fault is on. OB86 fires when a DP slave drops off the bus — but the root cause could be the cable, a connector, or a termination resistor. Measure impedance at both ends of the suspect segment. If you’re reading outside 135–165 Ω or seeing high noise levels, the cable is the culprit. Replace the full 100M run — don’t splice. Splices introduce impedance discontinuities that will haunt you at 1.5 Mbit/s and above.

2. Connector Swap — Don’t Forget Termination
When you install the new 6XV1830-0ET10, the two physical ends of each PROFIBUS segment must be terminated. Siemens PROFIBUS connectors (6ES7972-0BA52-0XA0 for 90°, 6ES7972-0BB52-0XA0 for 35°) have a built-in termination switch. Set it to ON at both segment ends, OFF at all intermediate nodes. Forgetting this is the single most common cause of intermittent bus faults after a cable replacement — the network runs fine at low baud rates but collapses at 1.5 Mbit/s or 12 Mbit/s due to signal reflections.

3. Shield Grounding — One Point, Not Two
Ground the cable shield at one end only per segment — typically at the DP master side. Grounding at both ends creates a ground loop that injects 50/60 Hz noise directly into the signal pair. In VFD-heavy environments (common in pump stations and conveyor systems), this will cause intermittent CRC errors that look like a failing slave but are actually EMI-induced. The 6XV1830-0ET10’s double shield (braid + foil) gives you excellent rejection when grounded correctly — don’t compromise it with a dual-ground mistake.

4. Baud Rate vs. Segment Length
After replacement, verify your baud rate against the new segment length. At 12 Mbit/s, maximum segment length is 100 m — exactly the length of this cable. If your run is longer, you either need a repeater (6ES7972-0AA02-0XA0) or you need to drop the baud rate. Don’t assume the previous installation was configured correctly; check the DP master configuration in STEP 7 or TIA Portal and confirm the baud rate matches what the network can physically support.

5. Post-Replacement Verification
After installation, run a live bus diagnostic from the DP master. In TIA Portal, use the Accessible Devices scan to confirm all slaves are back online. In STEP 7, check the DP master’s diagnostic buffer for any residual OB86 entries. If slaves are online but showing intermittent errors, re-check connector pin assignments — the 6XV1830-0ET10 uses a twisted pair (A-line / B-line); reversing them will cause the bus to fail silently at some baud rates.

Reliability in Harsh Conditions

The 6XV1830-0ET10 is not a general-purpose cable that happens to work on PROFIBUS. It is engineered from the conductor out for industrial field conditions. The AWG 22 stranded copper conductors are twisted to a controlled pitch that maintains the 135–165 Ω impedance specification across the full operating temperature range of -20°C to +60°C. In fixed installations, this covers everything from unheated outdoor cable trays in northern climates to the interior of control cabinets in tropical facilities running without air conditioning.

The double-shield construction — inner foil plus outer braided copper — is what separates this cable from cheaper alternatives in EMI-dense environments. In a typical automotive body shop, you have resistance welders, servo drives, and high-current bus bars all within meters of the PROFIBUS cable run. The 6XV1830-0ET10’s shield attenuation is sufficient to maintain signal integrity in these conditions, provided the shield is correctly grounded. The violet PVC outer jacket is rated for mechanical protection in cable trays and conduit, with a wall thickness that resists abrasion from cable tie edges and conduit entry points — a common failure mode in cables that are re-routed during plant modifications.

Vibration is another field reality this cable handles without degradation. The stranded conductor construction prevents work-hardening fatigue that would crack a solid conductor in a vibrating machine frame. For applications where the cable must flex repeatedly — such as a cable carrier on a moving axis — Siemens offers a flex-rated variant, but for the vast majority of fixed-installation PROFIBUS runs, the 6XV1830-0ET10 will outlast the equipment it connects.

Global Express Logistics

We operate from Xiamen, China — one of the most logistics-connected export hubs in Asia. When you confirm an order for the 6XV1830-0ET10, here’s what happens on our end:

Same Business Day: Stock is pulled, inspected, and packed. Export documentation is prepared — commercial invoice, packing list, and certificate of origin. For orders confirmed before 14:00 CST, DHL or FedEx Express collection is scheduled for the same afternoon.

Transit Times (Express): Southeast Asia: 1–2 business days. Europe (Germany, Netherlands, UK): 3–4 business days. North America (US, Canada): 3–5 business days. Middle East (UAE, Saudi Arabia): 2–3 business days. Australia: 3–4 business days. These are door-to-door estimates under normal customs clearance conditions.

Customs Documentation: We provide complete export documentation for smooth customs clearance in all major markets. HS code classification, declared value, and country of origin are accurately stated on all shipping documents. For customers in the EU, we can provide EUR.1 movement certificates where applicable.

Tracking: Full AWB tracking number provided immediately upon dispatch. For urgent shipments, we monitor the tracking status and proactively notify you of any customs holds or delivery exceptions. If your plant is down and you need the fastest possible delivery, contact us directly on WhatsApp before placing the order — we’ll confirm stock availability and the next available dispatch window in real time.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.