Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
GE In Stock OK

GE IC695PBM300LT PROFIBUS DP Master Module – PACSystems RX3i

Request verified availability, condition, replacement risk review, packing options and courier lead time for IC695PBM300LT.

Exact partIC695PBM300LT RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandGE Part NumberIC695PBM300LT ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ IC695PBM300LT

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
GE
Primary Part Number
IC695PBM300LT
Product Type
PLC Communication Module
Series / Family
PACSystems
Country of Origin
US
Catalog Category
Communication
Operating Temp.
0°C to +60°C
Warranty
12 months from date of shipment
Model confirmed for inquiry IC695PBM300LT Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

GE IC695PBM300LT: Class 1 PROFIBUS DP Master for PACSystems RX3i Backplane Networks

The GE IC695PBM300LT is a dedicated Class 1 PROFIBUS DP Master module engineered for deployment within GE’s PACSystems RX3i universal backplane architecture. In distributed control topologies where field device density is high and deterministic scan-cycle communication is non-negotiable, this module functions as the network coordinator — polling up to 125 DP slave nodes per scan, managing token-ring arbitration, and delivering process I/O data to the RX3i CPU via the high-speed backplane bus at rates that do not introduce measurable jitter into the control loop.

Unlike generic communication gateways, the IC695PBM300LT is a native backplane module. It occupies a standard RX3i universal slot and exchanges data with the host CPU through the 300 MB/s backplane fabric — not through an external serial or Ethernet bridge. This architectural decision eliminates the latency penalty associated with protocol conversion layers and ensures that PROFIBUS scan data arrives at the CPU within the same deterministic window as local I/O modules. For process applications where PID loop stability depends on consistent input refresh rates, this distinction is operationally significant.

The LT suffix designates lead-free, RoHS-compliant construction per EU Directive 2011/65/EU. This compliance status is a procurement prerequisite for projects in the European Union, Japan, South Korea, and an expanding list of regulated markets. The module’s electrical and functional performance is identical to the non-LT variant; the distinction is purely in solder alloy composition and component material declarations.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Part Number IC695PBM300LT
Platform GE PACSystems RX3i
Protocol Standard PROFIBUS DP (EN 50170 / IEC 61158 Type 3)
Master Class Class 1 DPM1 (cyclic data exchange)
Max Slave Nodes 125 per module
Max I/O per Slave 244 bytes input / 244 bytes output
Supported Baud Rates 9.6 kbps, 19.2 kbps, 45.45 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps
Physical Interface 9-pin D-sub female (RS-485, IEC 61158-2)
Backplane Compatibility IC695CHS007, IC695CHS012, IC695CHS016 (any universal slot)
Operating Temperature 0°C to +60°C
Storage Temperature -40°C to +85°C
Relative Humidity 5% to 95% non-condensing
Power Consumption Supplied via backplane (5 VDC)
RoHS Compliance Yes — LT (Lead-free) designation, EU Directive 2011/65/EU
Configuration Tool Proficy Machine Edition (PME) 8.0 or later
GSD File Support Yes — standard EN 50170 GSD format
Module Weight Approx. 400 g
Warranty 12 months from date of shipment

Hardware Logical Analysis

The IC695PBM300LT implements the PROFIBUS DP token-passing bus access protocol at the hardware level using a dedicated ASIC-based communication controller — separate from the RX3i CPU’s main processor. This co-processor architecture means that PROFIBUS token arbitration, slave polling sequencing, and error retry logic execute independently of the CPU scan cycle. The CPU is not burdened with protocol stack overhead; it simply reads and writes a shared memory image that the module refreshes autonomously.

The RS-485 physical layer driver on the module’s D-sub port is designed to operate across the full PROFIBUS baud rate range without manual configuration. Baud rate auto-detection occurs during network initialization, allowing the module to adapt to existing field installations without requiring parameter changes in PME. The driver circuit includes bus termination logic that must be correctly configured at segment endpoints — the module itself does not provide active termination, which is consistent with standard PROFIBUS segment design practice.

From an EMC perspective, the module’s backplane connector and internal signal routing are shielded against conducted and radiated interference consistent with IEC 61000-4 series test levels. The RS-485 interface is inherently differential, providing common-mode noise rejection across the cable run — a critical property in industrial environments where variable-frequency drives, welding equipment, and high-current switching loads generate broadband electromagnetic interference. Cable shield grounding at a single point per segment, combined with the module’s differential receiver, maintains signal integrity at 12 Mbps over cable runs up to 100 meters.

Diagnostic data from each slave node — including station status, watchdog timeout flags, and user-defined diagnostic bytes — is collected by the module’s co-processor and mapped into the RX3i CPU’s reference table. This allows ladder logic or structured text programs to monitor slave health at the application level without requiring separate diagnostic polling routines. The module also maintains internal counters for bus errors, retry events, and lost token conditions, accessible via PME’s online diagnostic view.

System Integration Benefits

  • Native Backplane Data Path: Module-to-CPU data transfer occurs over the 300 MB/s RX3i backplane bus, eliminating external cabling and protocol bridge latency that would otherwise add variable delay to the control loop input refresh.
  • Co-Processor Architecture: An onboard dedicated communication processor handles all PROFIBUS token-ring management and slave polling independently, freeing the RX3i CPU to execute application logic without protocol stack overhead.
  • Deterministic Scan Alignment: PROFIBUS I/O data is synchronized to the RX3i CPU scan cycle, ensuring that process variable updates arrive at a consistent point in each scan — a prerequisite for stable PID and cascade control loops.
  • GSD-Based Slave Configuration: Standard GSD file import in PME allows rapid addition of any EN 50170-compliant slave device without custom driver development, reducing commissioning time for heterogeneous field device networks.
  • Slave-Level Diagnostic Transparency: Per-slave diagnostic bytes are mapped directly into the CPU reference table, enabling application-layer fault detection and alarm generation without additional diagnostic modules or software layers.
  • Multi-Module Scalability: Multiple IC695PBM300LT modules can be installed in the same RX3i backplane (subject to slot and CPU resource limits), allowing PROFIBUS network segmentation for large installations exceeding 125 slave nodes.
  • Wide Baud Rate Coverage: Support for all standard PROFIBUS baud rates from 9.6 kbps to 12 Mbps enables integration with legacy field devices operating at lower speeds alongside modern high-speed instruments on the same controller platform.
  • RoHS Compliance for Global Projects: LT designation satisfies lead-free material requirements for EU CE marking, Japanese J-Moss, and South Korean RoHS regulations, removing a common procurement barrier for international project delivery.
  • Hot-Swap Capability: In supported RX3i configurations, the module can be replaced online without powering down the backplane, reducing planned maintenance windows and supporting high-availability system designs.
  • Unified Engineering Environment: Full configuration, diagnostics, and firmware management are handled within Proficy Machine Edition alongside all other RX3i modules, eliminating the need for separate PROFIBUS configuration tools.

Quality Assurance & Global Logistics

Every IC695PBM300LT unit supplied through siemensplc.com is sourced from verified industrial automation supply channels and subjected to a structured pre-shipment inspection process. Visual inspection covers board-level component integrity, connector condition, label authenticity, and absence of physical damage or corrosion. Where test equipment is available, functional verification of backplane interface and communication port operation is performed prior to packaging.

Units are packaged in anti-static ESD bags with desiccant, enclosed in foam-lined cartons rated for international air freight handling. Export documentation — including commercial invoice, packing list, and certificate of conformance — is prepared for each shipment to support customs clearance in destination countries. DHL Express, FedEx International Priority, and UPS Worldwide Express are the primary carriers for time-sensitive orders, with typical transit times of 3–5 business days from Xiamen, China to major industrial hubs in Europe, North America, Southeast Asia, and the Middle East. Sea freight consolidation is available for bulk orders where lead time permits.

All units carry a 12-month warranty from the date of shipment. Warranty coverage addresses defects in materials and workmanship under normal operating conditions. Technical support for installation, PME configuration, and network commissioning is available via email and WhatsApp throughout the warranty period and beyond.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.