GE IC695ETM001 Ethernet Communications Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for IC695ETM001.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- GE
- Primary Part Number
- IC695ETM001
- Product Type
- Ethernet Communications Module
- Series / Family
- PACSystems
- Manufacturer
- GE (General Electric / GE Fanuc / Emerson)
- Country of Origin
- US
- Catalog Category
- Communication
- Operating Temp.
- 0 °C to +60 °C
GE IC695ETM001 — Stop the Clock on Your Downtime. Ship Today from Xiamen.
Your PACSystems RX3i rack just lost Ethernet comms. The line is cold. Every minute offline is money bleeding out of the plant. The IC695ETM001 is the single-slot Ethernet module that puts your SCADA link, your Modbus TCP peers, and your EGD broadcasts back online — and we have it on the shelf right now in Xiamen, ready to clear customs and land on your dock faster than your maintenance team can finish the incident report.
We are not a broker guessing at lead times. We stock verified, original GE IC695ETM001 units, pull them from controlled storage, and hand them to DHL or FedEx the same business day you confirm the order. That is the only promise that matters when your plant is down.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | IC695ETM001 ✔ Ready to Ship |
| Manufacturer | GE (General Electric / GE Fanuc / Emerson) |
| Series | PACSystems RX3i |
| Module Type | Ethernet Communications Module |
| Network Ports | 2 × RJ-45, 10/100 Mbps, auto-negotiation |
| Supported Protocols | SRTP, Modbus TCP, EGD, FTP, HTTP, SNMP |
| Max Simultaneous Connections | 32 |
| Backplane Compatibility | RX3i Universal Backplane (IC695CHS012 / IC695CHS016) |
| Slot Requirement | Single universal slot, any position |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | −40 °C to +85 °C |
| Relative Humidity | 5 % to 95 % non-condensing |
| Power Draw | 3.3 W typical |
| Weight | 240 g |
| Minimum Firmware (PME) | 7.0 and above |
| Country of Origin | United States |
| Stock Status | In Stock — Ships Same Business Day |
Troubleshooting & Replacement Tips
The three fault patterns that send engineers searching for a replacement IC695ETM001:
1. LAN LED dark, no ping response. Before condemning the module, rule out the obvious: bad RJ-45 cable, failed switch port, or a corrupted IP configuration stored in the CPU’s hardware configuration table. Connect a laptop directly to Port 1 with a crossover cable and attempt a ping to the module’s configured IP. If no response, open PME, go to Hardware Configuration → ETM001 → Settings, and verify the IP address, subnet mask, and gateway match your network. If the module still does not respond after a power cycle, the Ethernet ASIC has likely failed — replace the module.
2. SRTP connections dropping intermittently under load. This is almost always a firmware mismatch between the ETM001 and the CPU. Check the CPU firmware revision in PME’s Target → Properties panel. The ETM001 firmware must be at or above the CPU firmware baseline. Mismatched firmware causes the SRTP server to reset active connections when the CPU transitions between RUN and STOP modes. Update both to the latest compatible revision using PME’s firmware upgrade utility before swapping hardware.
3. EGD exchanges not receiving data from peer controllers. EGD (Ethernet Global Data) is time-sensitive. If the consuming controller’s EGD exchange shows stale data or a consumed exchange fault, verify that the producing controller’s ETM001 is configured with the correct multicast or unicast destination address, and that the exchange period (in milliseconds) is achievable on your network segment. Managed switches must have IGMP snooping enabled for multicast EGD. A misconfigured VLAN is the most common field culprit.
Replacement procedure — what to do before you power up the new module:
- Export the full hardware configuration from PME before removing the failed module. Save the .csp file with a date stamp. You will need it to download configuration to the replacement unit.
- The IC695ETM001 has no DIP switches or rotary address selectors. All configuration is stored in the CPU’s hardware configuration, not in the module itself. The replacement module is factory-blank and will accept the downloaded configuration without any physical adjustment.
- Seat the module firmly into the same backplane slot. The RX3i backplane is hot-swap capable in most configurations, but confirm your CPU firmware supports hot-swap for communications modules before attempting a live swap on a running system.
- After seating, download the hardware configuration from PME. The module will initialize, acquire its IP address, and the LAN LEDs will cycle through their startup sequence (approximately 30–45 seconds). Do not interrupt power during this window.
- Verify firmware version post-download. If the replacement unit ships with older firmware than your system baseline, upgrade it immediately via PME’s firmware update function before returning the system to production.
- Confirm all SRTP connections, Modbus TCP server registrations, and EGD exchange tables are active in the module’s web diagnostic page (http://<module-IP>) before signing off the repair.
Reliability in Harsh Conditions
The IC695ETM001 was designed for the realities of industrial plant floors, not climate-controlled server rooms. The module’s conformal-coated PCB resists condensation and airborne contaminants common in food processing, chemical, and coastal facilities. The operating temperature ceiling of 60 °C means it survives in poorly ventilated control cabinets during summer shutdowns without thermal derating.
Vibration tolerance meets IEC 61131-2 requirements — the same standard that governs the mechanical integrity of programmable controllers used in compressor stations, offshore platforms, and rail-mounted control panels. The RJ-45 ports use locking-tab connectors that resist cable pull-out from vibration-induced cable movement, a failure mode that accounts for a disproportionate share of intermittent Ethernet faults in mobile and high-vibration installations.
Every IC695ETM001 unit we ship from Xiamen is stored in anti-static packaging inside a humidity-controlled warehouse. Units are not left on open shelving. Before dispatch, each module undergoes a visual inspection covering board-level physical integrity, label authenticity, and connector pin condition. We do not ship units with bent pins, cracked housings, or suspect label fonts — the counterfeit GE module market is real, and we treat it seriously.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to Xiamen Gaoqi International Airport and the Xiamen port complex. This geography is not accidental. It gives us same-day handoff to DHL Express and FedEx International Priority for shipments to Europe, Southeast Asia, the Middle East, and the Americas.
Standard dispatch timeline: Orders confirmed before 15:00 CST ship the same business day. Orders confirmed after 15:00 CST ship the following morning. We do not batch orders or hold shipments for consolidation unless you specifically request sea freight for large-volume orders.
Transit times (DHL Express / FedEx IP, door-to-door):
- Southeast Asia (Singapore, Thailand, Vietnam, Indonesia): 2–3 business days
- Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days
- Europe (Germany, UK, Netherlands, Poland): 4–5 business days
- North America (USA, Canada, Mexico): 4–6 business days
- Australia / New Zealand: 3–5 business days
- South America (Brazil, Chile, Colombia): 5–7 business days
Every shipment includes a commercial invoice, packing list, and country-of-origin declaration as standard. For regulated industries requiring additional documentation — material certificates, test reports, or specific customs commodity codes — notify us at the time of order and we will prepare the paperwork before dispatch. We have shipped IC695ETM001 units to petrochemical plants in the Middle East, automotive factories in Eastern Europe, and water treatment facilities in Southeast Asia. The logistics process is routine for us. It should be routine for you too.
Tracking numbers are issued within 2 hours of carrier pickup and sent directly to your contact email. We monitor shipments proactively and flag any customs holds or carrier exceptions before you have to ask.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.