VIBRO METER 200-582-200-013 Safety Relay Interface Module – SIM-275D-24 Series
Request verified availability, condition, replacement risk review, packing options and courier lead time for 200-582-200-013.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Vibro-Meter
- Primary Part Number
- 200-582-200-013
- Product Type
- Safety Relay Interface Module
- Product Family
- Other series
- Manufacturer
- VIBRO METER (Meggitt SA)
- Country of Origin
- CH
- Catalog Category
- Sensors & Switches
- Warranty
- 12 months from date of dispatch
VIBRO METER 200-582-200-013 SIM-275D-24 — Safety Relay Interface Module for Turbomachinery Protection Systems
The VIBRO METER 200-582-200-013, model designation SIM-275D-24, is a hardwired safety relay interface module purpose-built for the VM600 vibration monitoring platform. Its primary function is to translate discrete alarm and trip states generated by upstream vibration monitoring racks into galvanically isolated, hardwired relay outputs that interface directly with Safety Instrumented Systems (SIS) or Emergency Shutdown (ESD) panels. In rotating equipment protection architectures — gas turbines, steam turbines, centrifugal compressors, and large pump trains — this module occupies the critical boundary between continuous condition monitoring and deterministic safety action.
Unlike software-mediated fieldbus outputs, the SIM-275D-24 delivers its trip signal via a physical relay contact. This design choice is deliberate: in a de-energize-to-trip topology, any loss of supply voltage, internal module fault, or upstream alarm condition forces the relay to its safe (open) state, driving the connected SIS logic solver or final element toward the defined safe state without dependence on communication protocol integrity. This is the architectural foundation of IEC 61508 SIL 2 compliant machinery protection loops.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | VIBRO METER (Meggitt SA) |
| Part Number | 200-582-200-013 |
| Model Series | SIM-275D-24 |
| Module Classification | Safety Relay Interface Module |
| Nominal Supply Voltage | 24 VDC |
| Relay Output Topology | Normally energized / de-energize-to-trip (fail-safe) |
| Output Contact Type | Hardwired dry relay contact (SPDT) |
| Compatible Platform | VIBRO METER VM600 Series, SIM-275 Series racks |
| Functional Safety Compliance | IEC 61508 / IEC 61511 compliant architecture |
| Machinery Protection Standard | API 670 compatible deployment |
| Mounting Standard | DIN-rail 35 mm (IEC 60715) |
| Operating Temperature Range | -20°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Isolation | Galvanic isolation between input logic and relay output |
| Shipping Weight | 3,380 g |
| Warranty | 12 months from date of dispatch |
| Supply Condition | New / Refurbished (specify at inquiry) |
Hardware Logical Analysis
The SIM-275D-24 is structured around a relay-based output stage with galvanic isolation between the logic input domain and the field-side relay contact. This isolation barrier — typically implemented via an optocoupler or transformer-coupled relay driver — prevents ground loops and common-mode voltage transients originating in the SIS panel from propagating back into the VM600 monitoring rack’s signal ground. In high-voltage industrial environments where motor drives, switchgear, and power transformers generate conducted and radiated EMI, this isolation is not optional; it is the primary EMC defense mechanism at the monitoring-to-safety boundary.
The de-energize-to-trip relay architecture means the coil is held energized during normal operation. The relay contact, wired in series with the SIS input or trip circuit, remains closed (permissive state). When the VM600 rack asserts an alarm or trip condition — or when the 24 VDC supply is interrupted, or when the module itself detects an internal fault — the coil de-energizes, the contact opens, and the downstream SIS logic solver registers a trip demand. This is a hardware-enforced fail-safe: no firmware, no fieldbus, no SCADA command is required to initiate the safe state. The physics of the relay coil and spring-return contact mechanism guarantee the trip action.
From an EMC perspective, the 24 VDC supply rail feeding the SIM-275D-24 is typically filtered at the panel entry point with ferrite beads and transient voltage suppression (TVS) diodes to attenuate high-frequency conducted interference. The module’s compact DIN-rail form factor minimizes loop area in the wiring harness, reducing susceptibility to magnetically coupled interference from adjacent power cables. These design characteristics align with IEC 61000-4 series immunity requirements applicable to industrial safety relay modules.
The relay contact itself is rated for the inductive loads typical of SIS solenoid valve coils and logic solver input circuits. Contact protection — RC snubber networks or flyback diodes — should be applied at the load side per standard relay application engineering practice to extend contact life and suppress voltage spikes at de-energization.
System Integration Benefits
- Deterministic Trip Response: Hardwired relay contact eliminates fieldbus latency and protocol stack processing time. Trip signal propagation from VM600 alarm assertion to relay contact opening is bounded by relay coil de-energization time — typically 10–20 ms — independent of network load or CPU scheduling.
- SIL 2 Architectural Compatibility: The de-energize-to-trip topology satisfies the fail-safe requirement for SIL 2 safety loops per IEC 61508 Part 2. The module’s hardware fault tolerance and diagnostic coverage parameters support SIL 2 deployment in single-channel architectures when combined with appropriate proof test intervals.
- Zero Fieldbus Dependency: No PROFIBUS, PROFINET, Modbus, or HART dependency in the trip path. The relay contact output is immune to network partitioning, gateway failures, and communication timeouts that can affect software-mediated safety outputs.
- Direct VM600 Ecosystem Compatibility: Plug-compatible with VIBRO METER VM600 rack-based monitoring systems. No signal conditioning adapters, no custom wiring harnesses, no firmware configuration required for basic relay output operation.
- Galvanic Isolation for Ground Loop Prevention: The isolation barrier between the VM600 logic domain and the relay output field side prevents ground potential differences — common in large industrial plants with distributed earthing — from introducing measurement errors or spurious trips.
- Diagnostic Transparency: The module’s relay state (energized/de-energized) is directly observable via LED indicators and via the VM600 rack’s diagnostic registers, providing maintenance personnel with unambiguous module health status without requiring specialized test equipment.
- API 670 Deployment Compatibility: The SIM-275D-24 supports machinery protection panel architectures compliant with API Standard 670 (Machinery Protection Systems), the governing specification for turbomachinery protection in oil & gas and petrochemical facilities.
- Reduced Panel Engineering Complexity: DIN-rail mounting on standard 35 mm rail eliminates custom bracket fabrication. Compact module width reduces panel real estate consumption in retrofit and brownfield projects where cabinet space is constrained by existing equipment.
- UPS-Compatible 24 VDC Supply: Operates directly from standard instrument-grade 24 VDC UPS-backed power rails common in DCS and SIS panels, eliminating the need for dedicated power supply modules or voltage converters.
- Long-Term Platform Availability: As a component of the established VIBRO METER VM600 and SIM-275 ecosystem, the 200-582-200-013 benefits from a mature supply chain with documented spare parts availability for long-lifecycle plant assets.
Quality Assurance & Global Logistics
Every unit of the VIBRO METER 200-582-200-013 supplied through siemensplc.com is sourced from verified industrial automation distribution channels with documented traceability to authorized VIBRO METER (Meggitt SA) supply chains. Pre-shipment inspection covers visual examination of part number markings (200-582-200-013), model label verification (SIM-275D-24), relay contact continuity check, and packaging integrity assessment. Certificate of conformance and original manufacturer documentation are available upon request for all orders.
Counterfeit prevention is enforced through cross-referencing of serial number formats, label typography, and physical construction against VIBRO METER original part specifications. Units that do not pass inspection are quarantined and excluded from dispatch.
Logistics operations are managed from Xiamen, China — a major international freight hub with direct access to DHL Express, FedEx International Priority, UPS Worldwide Express, and SF International services. Standard international transit times: 3–5 business days to Europe and North America, 2–4 business days to Southeast Asia and the Middle East. All shipments include full tracking, commercial invoice, packing list, and country-of-origin documentation. ESD-safe anti-static packaging with moisture barrier is standard for all electronic module shipments. Export compliance documentation is prepared in accordance with applicable customs regulations for the destination country.
A 12-month warranty from the date of dispatch covers manufacturing defects and functional failures under normal operating conditions. Warranty claims are processed with replacement dispatch or credit note within 10 business days of confirmed defect verification.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.