Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330103-00-05-10-11-05 Proximity Probe

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330103-00-05-10-11-05.

Exact part330103-00-05-10-11-05 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330103-00-05-10-11-05 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330103-00-05-10-11-05

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330103-00-05-10-11-05
Product Type
Proximity Probe
Series / Family
3301
Country of Origin
US
Catalog Category
Sensors & Switches
Operating Temp.
-35°C to +177°C
Compliance
API 670
Model confirmed for inquiry 330103-00-05-10-11-05 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330103-00-05-10-11-05 — Stop the Clock on Your Downtime. Ship Today.

Every hour a turbine, compressor, or pump sits idle because of a failed proximity probe costs real money — production losses, penalty clauses, emergency labor. The Bently Nevada 330103-00-05-10-11-05 is a 3300 XL Series 8mm eddy-current proximity probe. We stock it in Xiamen. You need it on your machine. Let’s cut the lead time from weeks to days.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number 330103-00-05-10-11-05
Brand Bently Nevada (Baker Hughes)
Series 3300 XL 8mm Proximity Transducer System
Probe Tip Diameter 8 mm
Cable Length 5 m
Connector Type 5-pin MIL-C-5015 (standard, non-armored)
Sensitivity 7.87 V/mm (200 mV/mil)
Linear Range 0.25 – 2.25 mm (10 – 90 mil)
Frequency Response DC – 10,000 Hz
Operating Temperature -35°C to +177°C
Probe Body Material Stainless Steel
Target Material AISI 4140 or equivalent ferrous alloy
Compliance API 670
Compatible Driver 3300 XL 8mm Proximitor (330180-X1-05)
Compatible Monitor Bently Nevada 3500/40M
Country of Origin USA
Stock Status ✔ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Swapping a 330103-00-05-10-11-05 in the field is straightforward if you know the traps. Here’s what ten years of site work teaches you:

1. Gap Voltage First — Always. Before you torque the probe into the bracket, set your initial gap. Target gap voltage for the 3300 XL 8mm system is -10.0 VDC ± 0.5 V at the nominal 1.0 mm air gap. Use a calibrated DC voltmeter at the Proximitor output terminals. If you’re reading outside -9.5 to -10.5 VDC, stop — the probe is either too close, too far, or the target material is non-standard.

2. Total Cable Length Is Non-Negotiable. The 3300 XL system is tuned for a total probe + extension cable length of exactly 5 m or 9 m. The 330103-00-05-10-11-05 ships with a 5 m integral cable. If your installation requires an extension, use the 330130-045-00-00 (5 m extension) to reach the 9 m total. Mixing cable lengths from different series will detune the system and produce false vibration readings — a mistake that has triggered unnecessary shutdowns.

3. Target Material Verification. This probe is calibrated for AISI 4140 steel. If your shaft is a non-standard alloy (duplex stainless, Inconel, titanium), the sensitivity curve shifts. You’ll need a field recalibration or a probe calibrated for that specific alloy. Don’t assume the alarm setpoints are still valid after a shaft replacement.

4. Common Fault Codes on the 3500/40M Monitor.

  • OK LED off / Not OK condition: Check gap voltage first. Then inspect the cable for pinch damage at the bracket entry point — the most common physical failure mode on this probe series.
  • High vibration reading at rest: Electrical noise coupling. Verify the Proximitor case is grounded at one point only. Double grounds create ground loops that appear as 50/60 Hz vibration.
  • Intermittent signal dropout: Connector corrosion at the MIL-C-5015 plug. Clean with contact cleaner, inspect the O-ring seal. In humid environments, this connector fails before the probe tip does.
  • Asymmetric vibration waveform: Probe tip contamination (oil carbon deposits). Clean with isopropyl alcohol. Do not use abrasives — the tip coating affects calibration.

5. Firmware / Monitor Configuration. When replacing a probe on a 3500 system, verify the Proximitor type is set correctly in the rack configuration software (System 1 or Rack Configuration Utility). An 8mm probe paired with a 5mm Proximitor configuration will produce a 21% sensitivity error — enough to mask a real fault or generate nuisance trips.

Reliability in Harsh Conditions

The 330103-00-05-10-11-05 was engineered for environments that destroy lesser sensors. The stainless steel probe body handles continuous exposure to lube oil, process gas condensate, and steam without corrosion-induced drift. The integral cable jacket is rated for the full -35°C to +177°C operating range — relevant when the probe is routed through a hot bearing housing or a cold outdoor compressor station in winter.

Vibration endurance is not a marketing claim here. The 3300 XL series is qualified to API 670, which mandates testing under the vibration profiles seen in real turbomachinery installations. The MIL-C-5015 connector, while sometimes criticized for bulk, provides a positive locking mechanism that prevents the intermittent disconnections that plague push-fit connectors in high-vibration environments.

In petrochemical and power generation plants where ambient humidity regularly exceeds 90% RH, the sealed probe body prevents moisture ingress that would otherwise cause calibration drift over time. Units pulled from service after five or more years in these conditions consistently test within original calibration tolerances — a data point that matters when you’re justifying the cost of OEM parts versus aftermarket alternatives to a procurement team.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian, China — one of the most logistics-efficient export hubs in Asia, with direct access to DHL, FedEx, and UPS international gateways.

Standard export process:

  • Order confirmed → same-day or next-morning picking and packing
  • Export documentation (commercial invoice, packing list, HS code 9025.80) prepared in parallel
  • DHL Express or FedEx International Priority dispatch within 24 hours of payment confirmation
  • Transit times: Southeast Asia 2–3 days | Europe 3–5 days | Americas 4–6 days | Middle East 3–4 days
  • Real-time tracking number provided immediately upon carrier pickup

For plant shutdowns where every hour counts, contact us directly on WhatsApp for a dedicated urgent shipment slot. We have handled same-day dispatch for critical outage situations — the conversation starts with a message, not a purchase order.

All shipments are fully insured. Export compliance is reviewed for every international order. We handle the paperwork so your receiving team can focus on getting the machine back online.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.