Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330130-080-00-05 Proximity Cable Extension

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330130-080-00-05.

Exact part330130-080-00-05 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330130-080-00-05 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330130-080-00-05

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330130-080-00-05
Product Type
Proximity Cable Extension
Series / Family
3301
Manufacturer
Bently Nevada (Baker Hughes)
Country of Origin
US
Catalog Category
Sensors & Switches
Operating Temp.
–40 °C to +85 °C (cable jacket rated)
Compliance
API 670 machinery protection systems
Model confirmed for inquiry 330130-080-00-05 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330130-080-00-05 Proximity Cable Extension — Stop the Clock on Your Downtime

Every minute a turbomachinery train sits idle costs real money. When the proximity measurement loop breaks — whether from cable fatigue, connector corrosion, or a maintenance mishap — your vibration monitoring system goes blind. No gap voltage signal means no shaft position data, no early-warning alarms, and a protection system that cannot do its job. The Bently Nevada 330130-080-00-05 is the 8-meter coaxial cable extension that closes that gap — literally. We stock it in Xiamen and ship it globally within 24 hours of order confirmation. While your competitors wait weeks for OEM lead times, your machine is back online.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value
Manufacturer Bently Nevada (Baker Hughes)
Part Number 330130-080-00-05
Series 3300 XL Proximity Transducer System
Cable Type Coaxial, fully shielded, low-loss
Cable Length 8 meters (suffix “-080” per BN naming convention)
Connector Standard 3300 XL system-standard coaxial terminations
Signal Type Eddy-current proximity, DC-coupled analog
Compatible Probes 3300 XL 8mm series (330103-xx-xx)
Compatible Drivers 3300 XL Proximitor / 330180 series
Compliance API 670 machinery protection systems
Operating Temperature –40 °C to +85 °C (cable jacket rated)
Weight ~350 g
Country of Origin USA
Stock Status ✅ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Common failure signatures that point to the 330130-080-00-05:

  • Gap voltage drift without shaft movement — If your 3500 rack is reporting a slowly shifting DC gap voltage with no corresponding rotor displacement, suspect the cable extension before the probe or proximitor. Flex fatigue at the connector boot is the #1 failure mode on units with >5 years of service.
  • Intermittent OK/NOT OK relay chatter — Caused by a marginal shield connection inside the extension. Wiggling the cable near the proximitor end while watching the 3500 channel status will confirm this. Replace immediately — intermittent faults in API 670 systems are a compliance violation.
  • High noise floor on the proximitor output — Measured as AC ripple on the gap voltage. A compromised shield allows EMI pickup from adjacent VFD cables or bus bars. The 330130-080-00-05’s full-length braid shield is the fix.
  • Sudden channel fault after maintenance — Technicians frequently damage the coaxial connector during routine inspections. Inspect the center pin and dielectric for deformation before condemning the probe or proximitor.

Replacement procedure — field-proven steps:

  1. Verify system de-energization or bypass authorization. On API 670 systems, confirm the channel is in bypass mode on the 3500 rack before disconnecting. Removing a live proximity loop without bypass will trigger a trip.
  2. Document the existing gap voltage. Note the DC gap reading at the proximitor before disconnection. Your target after replacement is within ±0.5 VDC of the original value — if it’s outside this range, the probe-to-target gap has shifted and requires mechanical re-gapping.
  3. Inspect connector mating surfaces. Clean the coaxial connectors with isopropyl alcohol (IPA) and a lint-free swab. Verify the center pin is straight and the dielectric is undamaged on both the probe and proximitor ends.
  4. Route the new cable extension away from power conductors. Maintain a minimum 150 mm separation from VFD output cables and motor leads. Use dedicated conduit or cable tray where possible.
  5. Torque connectors to specification. Bently Nevada specifies finger-tight plus 1/4 turn for the coaxial connectors. Over-torquing crushes the dielectric; under-torquing causes intermittent contact.
  6. Verify gap voltage after reconnection. Power up the proximitor and confirm the gap voltage is within the system’s calibrated range (typically –10 VDC ± 0.5 V for an 8mm probe at nominal gap). If outside range, re-gap the probe before releasing the bypass.
  7. Release bypass and confirm OK status on the 3500 rack. Check all associated channels — radial X, radial Y, and axial if applicable — before returning the machine to service.

Configuration notes specific to the 330130-080-00-05: No DIP switches, no firmware, no addressing — this is a passive cable assembly. However, the total system cable length (probe cable + extension) must not exceed the proximitor’s rated loop length. Verify your 330180-series proximitor datasheet for the maximum combined cable length before installing an 8-meter extension on an existing probe cable run.

Reliability in Harsh Conditions

Turbomachinery environments are hostile to instrumentation. The 330130-080-00-05 is built to survive where lesser cables fail:

  • Vibration fatigue resistance: The cable jacket and connector strain relief are engineered for continuous exposure to broadband vibration spectra typical of rotating equipment foundations. The coaxial construction maintains concentricity under dynamic loading, preventing impedance variation that would corrupt the gap voltage signal.
  • Thermal cycling tolerance: Compressor and turbine installations see wide temperature swings between cold startups and full-load operation. The cable dielectric and jacket materials maintain their electrical and mechanical properties across the rated –40 °C to +85 °C range without cracking or delamination.
  • Chemical and moisture resistance: Oil mist, process gas condensate, and cleaning solvents are facts of life in machinery halls. The outer jacket resists hydrocarbon exposure, and the connector design minimizes ingress points. For installations in wash-down zones, additional conduit sealing is recommended per API 670 Annex D.
  • EMI immunity: The full-length braid shield, terminated at both ends, provides effective attenuation of radiated interference from adjacent VFDs, switchgear, and high-current bus bars. This is not a cost-reduced design with partial shielding — it is the OEM specification that your 3300 XL system was calibrated with.

Global Express Logistics

Our Xiamen warehouse operates on a 24-hour dispatch cycle. Here is exactly what happens after you confirm your order:

  • Day 0 — Order confirmation & payment: Stock is physically reserved and pulled from the shelf. A commercial invoice, packing list, and certificate of origin are prepared simultaneously.
  • Day 1 — Export clearance & handover: The shipment clears Chinese customs export procedures and is handed to DHL Express or FedEx International Priority — whichever offers the faster transit to your destination. For most Asia-Pacific destinations, DHL is faster; for North America and Europe, FedEx IP is typically preferred.
  • Day 2–4 — In-transit to destination: DHL and FedEx express services from Xiamen reach Singapore, Malaysia, Thailand, and Vietnam in 1–2 business days; UAE, Saudi Arabia, and India in 2–3 days; Germany, UK, Netherlands, and France in 3–4 days; USA and Canada in 3–5 days.
  • Tracking: A waybill number is sent to you within 2 hours of carrier pickup. You can track the shipment in real time on the DHL or FedEx portal.
  • Import documentation: We provide all documents required for customs clearance — commercial invoice with declared value, packing list with net/gross weights and dimensions, and certificate of origin. HS code 8544.42 (insulated electric conductors) is typically applicable; confirm with your customs broker for your jurisdiction.
  • Emergency same-day dispatch: For confirmed critical shutdowns, contact us before 14:00 CST and we will prioritize same-day handover to the carrier.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.