Bently Nevada 330851-02-000-060-50-00-00 Proximity Transducer
Request verified availability, condition, replacement risk review, packing options and courier lead time for 330851-02-000-060-50-00-00.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330851-02-000-060-50-00-00
- Product Type
- Proximity Transducer
- Series / Family
- 3308
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Compliance
- API 670, IEC 60079, CE, RoHS
330851-02-000-060-50-00-00 — Every Hour of Downtime Costs You. We Ship Today.
Your turbine is down. The 3300 XL rack is throwing a Not OK on the proximity channel. Maintenance is standing by. Procurement is on the phone. You need this transducer — not in three weeks, not in ten days. Now.
We stock the Bently Nevada 330851-02-000-060-50-00-00 eddy-current proximity transducer in Xiamen and ship same-day via DHL Express or FedEx International Priority. One call, one part, one shipment — your line back online.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | 330851-02-000-060-50-00-00 | ✔ Ready to Ship |
| Brand | Bently Nevada | |
| Series | 3300 XL | |
| Sensor Type | Eddy-Current Proximity Transducer | |
| Probe Tip Diameter | 8 mm | |
| Nominal Measurement Range | 0 – 2.0 mm (0 – 80 mil) | |
| Linear Range | 0.25 – 1.77 mm (10 – 70 mil) | |
| Scale Factor | 7.87 V/mm (200 mV/mil) | |
| Integral Cable Length | 6.0 m | |
| Supply Voltage | −24 VDC nominal | |
| Frequency Response | DC to 10 kHz (−3 dB) | |
| Probe Tip Temperature | −35 °C to +177 °C | |
| Housing Material | 316 Stainless Steel | |
| Target Material (Standard Cal.) | AISI 4140 / 4340 Steel | |
| Connector | Integral coaxial, 3-pin | |
| Compliance | API 670, IEC 60079, CE, RoHS | |
| Origin | United States | |
| Shipping Origin | Xiamen, China | ✔ Same-Day Dispatch |
Troubleshooting & Replacement Tips
Ten years of field calls on 3300 XL systems teach you the same lessons over and over. Here is what actually matters when you are swapping this transducer under pressure.
Fault Code NOT OK / Channel Fault on 3300/16 Monitor
Ninety percent of the time this is a gap voltage out of range, not a dead probe. Before condemning the transducer, check the Proximitor output voltage at the BNC test point. You want −10 VDC ±0.5 V at nominal gap (1.0 mm / 40 mil). If you are reading −24 V or 0 V, the probe tip is either touching the shaft or has pulled out of the bracket entirely. Adjust gap first.
Confirming the Probe is Actually Failed
Disconnect the extension cable at the Proximitor input. Measure resistance across the probe coil pins: you should see 5–8 Ω. An open circuit (OL) or dead short (0 Ω) confirms a failed probe winding. Replace the probe assembly — the 330851-02-000-060-50-00-00 is a complete probe-plus-cable unit, not a field-repairable item.
Gap Setting After Installation
Mount the new probe in the existing bracket. With the shaft stationary, adjust the probe axial position until the Proximitor output reads −10.0 VDC. Lock the jam nut to the torque specified in BN procedure 141534. Do not rely on the old probe’s thread depth — cable stiffness and bracket wear mean the gap will be different.
Extension Cable Compatibility
The 330851-02-000-060-50-00-00 uses a 6 m integral cable. If your system uses a 5 m extension (330130-045-00-00), the total system cable length is 11 m — verify this matches the Proximitor driver calibration. Mixing cable lengths without recalibrating the driver shifts the scale factor and introduces measurement error that will not trigger a fault but will corrupt your vibration trend data.
Target Material Correction
Standard calibration is for AISI 4140/4340 steel. If your shaft is Inconel, titanium, or duplex stainless, the effective scale factor changes by up to 15%. Apply the material correction factor from BN application note 141534 or contact us — we can supply application-specific calibration data sheets.
Firmware / Monitor Compatibility
The 330851 series is natively compatible with all 3300 XL monitor firmware revisions. No firmware update is required on the monitor when replacing like-for-like. If you are migrating from a 3300/16 to a 3500/40M, the probe is electrically compatible but the monitor configuration database must be updated to reflect the new channel assignment and alert setpoints.
Common Installation Mistake
Do not route the integral cable in the same conduit as power wiring. The coaxial cable is low-impedance but not immune to 50/60 Hz induction from VFD output cables. Keep a minimum 150 mm separation or use a dedicated instrumentation conduit. Unexplained 1× or 2× noise on the vibration spectrum is almost always a grounding or cable routing issue, not a probe defect.
Reliability in Harsh Conditions
The 330851-02-000-060-50-00-00 is not a laboratory instrument. It is built to survive the environments where turbomachinery actually operates.
The 316 stainless steel probe body resists oil mist, steam condensate, and the aggressive process atmospheres found in petrochemical and LNG facilities. The integral cable jacket is rated for continuous exposure to lubricating oils and hydraulic fluids without swelling or cracking. The coaxial construction provides inherent shielding against the high-frequency electrical noise generated by variable-frequency drives and nearby switchgear.
Vibration is the one thing a vibration sensor must handle without complaint. The probe assembly is rated to withstand 20 g continuous vibration across 10–2000 Hz — the bracket and jam nut will fail before the probe does. The probe tip temperature rating of +177 °C covers the bearing pedestal temperatures found on the hot-end of industrial gas turbines and high-pressure steam turbines without requiring any additional thermal protection.
In humid tropical environments and coastal installations, the stainless housing and sealed coaxial connector prevent moisture ingress that would otherwise cause corrosion-driven drift in the output signal. Units destined for offshore platforms or marine applications can be supplied with additional conformal coating on the connector interface — specify at time of order.
Every unit we dispatch has been stored in anti-static, moisture-barrier packaging with desiccant. Shelf life from our warehouse to your site does not degrade the calibration. You install it, set the gap, and it reads correctly from the first rotation.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. This is not a drop-ship operation. Stock is physically on our shelf.
Standard Express Timeline (from order confirmation):
- Order confirmed before 14:00 CST → same-day dispatch
- DHL Express Worldwide → 2–4 business days to most of Europe, Middle East, Southeast Asia
- FedEx International Priority → 1–3 business days to North America and Australia
- UPS Worldwide Express → available on request for specific destinations
We prepare all export documentation in-house: commercial invoice, packing list, and HS Code 9031.80 declaration. For customers in the EU, we can provide EUR.1 movement certificates and ATEX documentation packages where required. DDP (Delivered Duty Paid) shipping is available to most destinations — you receive the part at your door with no customs clearance burden on your side.
For critical shutdowns where every hour counts, contact us directly on WhatsApp before placing the order. We will confirm stock, cut the commercial invoice, and hand the shipment to DHL within the hour. Tracking number is sent to you the moment the courier scans the package.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.