Bently Nevada 88984-02 Proximitor Sensor
Request verified availability, condition, replacement risk review, packing options and courier lead time for 88984-02.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 88984-02
- Product Type
- Proximitor Sensor
- Series / Family
- 3300 XL
- Manufacturer
- Bently Nevada (Baker Hughes)
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Operating Temp.
- –35°C to +85°C (Proximitor housing)
- Compliance
- API 670 (5th Ed.), IEC 61511, CE, RoHS
Bently Nevada 88984-02 — Stop the Clock on Your Downtime. Ship Today.
Every hour a turbine, compressor, or critical rotating machine sits idle costs real money — production losses, contractual penalties, and the kind of pressure that makes a 2 AM phone call feel routine. The Bently Nevada 88984-02 3300 XL Proximitor® sensor is on our shelf in Xiamen right now. We don’t quote lead times in weeks. We quote in hours.
This is not a catalog listing. This is a stocked unit, inspected, and ready to clear customs today. If your DCS is throwing a Proximitor Power Supply Fault or your vibration monitor has gone dark on a critical shaft, this page exists for one reason: get you back online fast.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | 88984-02 | ✔ Ready to Ship |
| Manufacturer | Bently Nevada (Baker Hughes) | 100% Original OEM |
| Series | 3300 XL Proximitor® | Current Production |
| Measurement Principle | Eddy-current, non-contact displacement | — |
| Output Signal | –24 VDC nominal (gap-proportional voltage) | — |
| Sensitivity | 7.87 V/mm (200 mV/mil) | — |
| Linear Measurement Range | 0.25 mm – 2.26 mm (10 – 89 mil) | — |
| Frequency Response | DC to 10,000 Hz (–3 dB) | — |
| Supply Voltage | –24 VDC (–20 to –26 VDC) | — |
| Operating Temperature | –35°C to +85°C (Proximitor housing) | — |
| Target Material (Standard Cal.) | AISI 4140 steel | — |
| Hazardous Area Certification | ATEX Zone 1/2 | FM Class I Div 1/2 | — |
| Connector Type | MIL-C-5015 style | — |
| Weight | 550 g (approx.) | — |
| Compliance | API 670 (5th Ed.), IEC 61511, CE, RoHS | — |
| Ship-From Location | Xiamen, China | ✔ Same-Day Dispatch Available |
Troubleshooting & Replacement Tips
Ten years of field calls on 3300 XL systems teach you the same failure patterns. Here is what to check before you pull the unit — and what to watch when you install the replacement.
Common Fault Signatures That Point to the 88984-02:
- Monitor shows “OK” LED off, Danger LED solid — Proximitor output has railed. Check DC supply first (must be –24 VDC ±10%). If supply is clean, the Proximitor oscillator circuit has failed. Replace the 88984-02.
- Vibration reading frozen or pegged at –24 V — Open circuit in the probe/extension cable or Proximitor internal fault. Disconnect the probe at the Proximitor input and measure output voltage. If it does not shift to approximately –12 VDC (mid-range open-circuit), the Proximitor is dead.
- Intermittent high-vibration trips with no process change — Check the MIL-C-5015 connector for fretting corrosion, especially in high-vibration installations. Clean contacts with IPA. If the fault persists, the Proximitor’s internal oscillator is thermally cycling — replace before the next planned outage window.
- Keyphasor signal lost — If the 88984-02 is used in a Keyphasor® application, verify the gap voltage is within the linear range (–10 to –18 VDC at the notch). A gap outside this range will cause the monitor to lose the once-per-revolution reference entirely.
Replacement Procedure — Field Checklist:
- Confirm matched system. The 88984-02 must be used with a factory-matched probe and extension cable. The cable length is encoded in the Proximitor calibration. Swapping only the Proximitor while keeping a mismatched cable will introduce a linearity error of up to 8%. Verify the cable part number against the Proximitor label before installation.
- Set the gap before energizing. With the machine at rest, set the probe gap to the midpoint of the linear range — typically 1.0–1.27 mm (40–50 mil) for standard 8 mm probes. Use a calibrated gap tool or a digital multimeter on the Proximitor output: target –10 to –12 VDC at rest.
- No DIP switches or address configuration required. The 88984-02 is a passive analog device. There is no firmware, no address setting, and no self-commissioning sequence. Plug in, set gap, verify output voltage, done.
- Verify monitor card compatibility. The 88984-02 is designed for the 3300 XL monitor platform (3300/16, 3300/55, 3300/25). It is backward-compatible with legacy 3300 series monitors but confirm the monitor’s input impedance specification — some older cards require a 100 Ω termination resistor that the XL series does not.
- Check for ground loops. The Proximitor case is typically grounded at one point only. In installations where the machine frame and the control room ground differ by more than 1 V, you will see a 50/60 Hz noise component on the vibration signal. Use an isolation barrier if required.
- Functional test before restart. With the machine still at rest, rotate the shaft by hand (if accessible) and confirm the vibration monitor shows a clean, low-noise signal. A healthy 88984-02 will show less than 0.5 mil pk-pk noise floor at rest.
Reliability in Harsh Conditions
The 88984-02 was not designed for a clean lab. It was designed for the turbine deck of an offshore platform in the South China Sea, the compressor bay of a desert gas plant at 55°C ambient, and the basement of a steel mill where vibration never stops. The design reflects that reality.
The Proximitor housing is sealed against moisture ingress and rated for continuous operation from –35°C to +85°C without derating. The internal oscillator circuit uses components selected for thermal stability — sensitivity drift across the full temperature range is held to less than ±1% of full scale, which matters when your alarm setpoints are tight.
Mechanical vibration is handled at the connector level. The MIL-C-5015 style connector provides positive locking under vibration loads that would work a standard BNC or M12 connector loose within weeks. In installations where the Proximitor is mounted directly on the machine casing — common in retrofit applications — the housing withstands the continuous broadband vibration environment without fatigue failure of internal solder joints.
The eddy-current sensing element itself has no moving parts and no wear mechanism. The only consumable in the system is the probe tip, which is subject to slow erosion in high-velocity steam or process gas environments. The Proximitor electronics, by contrast, are solid-state and have demonstrated MTBF figures exceeding 100,000 hours in documented field populations. When a 3300 XL system fails, the Proximitor is rarely the first component to go — but when it does fail, it fails hard and fast, which is why having a spare on the shelf is not optional for any serious reliability program.
Global Express Logistics
Our warehouse is in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to Xiamen Gaoqi International Airport and the Port of Xiamen. This is not a drop-ship arrangement. The unit is physically here, and we control the dispatch process end to end.
Standard export workflow for urgent orders:
- Order confirmed before 14:00 CST — Same-day dispatch via DHL Express or FedEx International Priority. Tracking number issued within 2 hours of pickup.
- DHL Express transit times from Xiamen: Southeast Asia 1–2 days | Middle East 2–3 days | Europe 3–4 days | North America 3–5 days | Australia 2–3 days.
- Export documentation — Commercial invoice, packing list, and certificate of origin prepared same day. For ATEX-certified units, we include the EU Declaration of Conformity. HS Code 9031.80 applies for customs classification.
- Customs clearance support — We provide pre-shipment documentation packages optimized for fast customs release in major import markets. For time-critical shipments, we recommend DHL’s customs pre-clearance service, which we can coordinate on your behalf.
- Freight insurance — All shipments above USD 500 are covered by cargo insurance as standard. No additional charge.
If your plant is in a location with complex import requirements — India IGST, Brazil ICMS, or Saudi SABER certification — contact us before ordering. We have handled these corridors before and can advise on the fastest compliant route.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.