Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Yokogawa In Stock OK

Yokogawa A2PW504-S0130 A2EN501-S11130 A2NN30D-440101113 DCS Module – CENTUM VP

Request verified availability, condition, replacement risk review, packing options and courier lead time for A2PW504-S0130.

Exact partA2PW504-S0130 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandYokogawa Part NumberA2PW504-S0130 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ A2PW504-S0130

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Yokogawa
Primary Part Number
A2PW504-S0130
Product Type
DCS Field Control Node
Series / Family
CENTUM VP
Country of Origin
JP
Catalog Category
DCS & Safety Modules
Operating Temp.
0 °C to +55 °C
Warranty
12 months from shipment date — manufacturing defects covered
Compliance
CE, RoHS 2
Model confirmed for inquiry A2PW504-S0130 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Yokogawa A2PW504-S0130 / A2EN501-S11130 / A2NN30D-440101113 — Tripartite Node Assembly for CENTUM VP Distributed Process Control

The A2PW504-S0130, A2EN501-S11130, and A2NN30D-440101113 form a functionally complete, slot-resident node assembly on Yokogawa’s A2-series backplane, designed for deployment within CENTUM VP and CS 3000 distributed control systems. Each module occupies a dedicated backplane slot and performs a discrete, non-overlapping function: power conditioning and rail regulation, deterministic Vnet/IP network arbitration, and real-time field I/O execution respectively. The three modules operate as a tightly coupled subsystem — the power supply feeds regulated DC rails to both the communication node and the field control node, while the communication node provides the high-speed token-bus link through which the field control node exchanges process data with the domain station at fixed, guaranteed intervals.

This assembly is specified for continuous-duty process environments including hydrocarbon refining, LNG terminal automation, pharmaceutical batch sequencing, power generation balance-of-plant control, and municipal water treatment SCADA. The node architecture supports Yokogawa’s dual-redundancy scheme for both the A2EN501-S11130 and A2NN30D-440101113, enabling SIL 2-rated control loop configurations under IEC 61511 without external safety relay hardware. Compatibility spans CENTUM VP R4 through R6 and CS 3000 R3, providing a direct upgrade path for brownfield installations without I/O rewiring or function block reprogramming.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter A2PW504-S0130 A2EN501-S11130 A2NN30D-440101113
Module Role Node Power Supply Unit Vnet/IP Communication Node Field Control Node (FCN)
AC Input Range 100–240 V AC, 50/60 Hz Backplane-powered Backplane-powered
DC Backup Input 24 V DC (simultaneous with AC)
Regulated Output Rails +5 V DC, +24 V DC
AC→DC Transfer Time <20 ms (bumpless)
Network Protocol Vnet/IP over 100BASE-TX Vnet/IP + field I/O bus
Bus Cycle Time 100 ms (fixed, deterministic) 100 ms / 500 ms selectable
SOE Event Resolution <10 ms timestamping <10 ms
Max FCN Nodes / Domain 64 nodes
Max I/O Modules / Node 10 modules
Redundancy Architecture Dual AC+DC bumpless transfer Dual hot-standby ring Dual hot-standby
Failover Completion <20 ms <100 ms (hardware-initiated) <1 s
Processor Core Dedicated ASIC (no OS jitter) 32-bit RISC + RTOS kernel
Program Storage Non-volatile flash (power-loss safe)
Field Isolation Barrier 500 V DC optical isolation
EMC Immunity — EFT IEC 61000-4-4, 2 kV
EMC Immunity — Surge IEC 61000-4-5, 1 kV
Operating Temperature 0 °C to +55 °C 0 °C to +55 °C 0 °C to +55 °C
Storage Temperature −25 °C to +70 °C −25 °C to +70 °C −25 °C to +70 °C
Relative Humidity 10–90% RH, non-condensing 10–90% RH, non-condensing 10–90% RH, non-condensing
Backplane Interface A2-series node unit A2-series node unit A2-series node unit
Compliance CE, RoHS 2 CE, RoHS 2 CE, RoHS 2, IEC 61511
Warranty 12 months from shipment date — manufacturing defects covered

Hardware Logical Analysis

The A2PW504-S0130 uses a switching-mode conversion topology with active power factor correction (PFC), sustaining an input power factor above 0.95 across the full 100–240 V AC range. Its dual-input arbitration circuit monitors AC mains and 24 V DC backup in parallel. AC dropout detection triggers at voltages below 85 V AC; the transfer relay engages the DC rail within 20 ms — within the hold-up window of downstream module bulk capacitors — delivering zero-glitch backplane continuity. Each output rail is individually fused and supervised by a dedicated voltage monitoring circuit. If any rail deviates beyond ±5% of nominal, the supervisory circuit asserts a hardware fault signal to the A2NN30D, initiating a controlled node shutdown sequence rather than an uncontrolled processor reset. This prevents partial-write corruption of process output registers during power anomalies.

The A2EN501-S11130 implements the full Vnet/IP protocol stack in dedicated ASIC logic, bypassing any general-purpose processor and eliminating OS scheduling latency from the communication path entirely. The token-passing arbitration mechanism allocates each node a fixed transmission window within every 100 ms bus cycle, independent of network load — a determinism guarantee that standard IEEE 802.3 CSMA/CD Ethernet cannot provide without external QoS infrastructure. Two independent 100BASE-TX physical ports support the dual-redundant ring topology. The ASIC monitors frame integrity on both ports simultaneously; upon detecting consecutive frame loss on the active port, it switches the active path in hardware within one bus cycle (<100 ms) without any CPU interrupt or software intervention. This hardware-level path switching is the key distinction between Vnet/IP and software-managed redundant Ethernet implementations, where OS interrupt latency can extend switchover to several seconds.

The A2NN30D-440101113 executes IEC 61131-3 function block diagrams on a 32-bit RISC processor under a hard real-time operating system (RTOS). The RTOS scheduler enforces strict deadline monotonic priority on the I/O scan task, preempting all lower-priority threads to guarantee field value acquisition, control calculation, and output write completion within the configured cycle period. The PCB employs a multi-layer ground plane stack-up with dedicated analog and digital ground islands, joined at a single star point to prevent digital switching noise from coupling into analog measurement paths. Ferrite bead filters on all I/O bus lines attenuate high-frequency common-mode noise above 10 MHz. TVS diodes on field-side connector pins clamp transient overvoltages to safe levels within nanoseconds, providing the first line of defense against inductive load switching transients in motor control and valve actuator applications. The 500 V DC optical isolation barrier between backplane logic and field I/O bus lines eliminates ground loop current paths in installations where field enclosures and control room panels share different earth reference potentials — a common condition in large-footprint petrochemical plants.

System Integration Benefits

  • Automatic configuration download on insertion: Upon hot-swap insertion, the A2NN30D contacts the domain station and downloads its complete function block configuration from the engineering database. No manual re-programming is required. A trained technician can complete a node replacement and return the loop to automatic control in under 15 minutes, minimizing process deviation during unplanned maintenance.
  • Hard real-time scan cycle with zero jitter: The RTOS-enforced I/O scan guarantees process variable delivery to the control loop at exactly the configured 100 ms or 500 ms interval. Consistent update timing is a prerequisite for stable derivative action in PID controllers managing fast-response loops such as pressure and flow, where variable scan jitter introduces artificial derivative spikes.
  • Hardware-initiated redundancy switchover: Both the A2EN501 and A2NN30D trigger failover via hardware watchdog timeout, not software polling. This means switchover completes even if the primary module’s processor has entered an unresponsive state — a failure mode that software-polled redundancy schemes cannot detect until a polling timeout expires.
  • Out-of-band diagnostic reporting: The A2EN501 transmits node health telemetry — CPU utilization, memory allocation, Vnet/IP error counters, and power rail status — to the CENTUM VP HIS over a dedicated diagnostic channel that does not consume control cycle bandwidth. Operators receive continuous visibility into node health without any impact on process control determinism.
  • Domain scalability to 64 nodes: A single Vnet/IP domain accommodates up to 64 A2NN30D field control nodes, each managing up to 10 I/O modules. This architecture allows a single pair of domain stations to supervise more than 640 I/O modules distributed across geographically separated field enclosures, without additional communication infrastructure or intermediate concentrators.
  • Flash-resident program retention across power cycles: Function block programs, PID tuning parameters, and alarm setpoints stored in the A2NN30D’s non-volatile flash memory survive both controlled shutdowns and unplanned power loss events. There is no dependency on battery-backed SRAM, eliminating the battery replacement maintenance interval present in older DCS node designs.
  • Documented SIL 2 pathway under IEC 61511: The dual-redundant node architecture, combined with Yokogawa’s certified safety function block library, provides a documented engineering basis for SIL 2 safety instrumented function (SIF) design. This reduces the safety lifecycle engineering effort for process plants required to comply with IEC 61511 or equivalent national standards.
  • Brownfield compatibility with CS 3000 R3: The A2-series modules are electrically and firmware-compatible with CS 3000 R3 installations. Existing function block programs, I/O module wiring, and engineering database configurations migrate without modification, allowing plants to replace end-of-life CS 3000 nodes with CENTUM VP-compatible hardware during scheduled turnarounds rather than requiring a full system replacement project.

Quality Assurance & Global Logistics

Every unit dispatched from our Xiamen, China facility passes a structured pre-shipment inspection covering label authenticity verification against Yokogawa’s published OEM part number database, connector pin condition assessment, and physical integrity inspection. A certificate of conformance and itemized packing list accompany each shipment.

Modules are individually sealed in ESD-protective anti-static bags, cushioned in foam-lined inner cartons, and enclosed in moisture-barrier outer packaging rated for international air and sea freight handling. Export documentation — commercial invoice, packing list, and HS 8537.10 classification — is prepared per shipment to support customs clearance at destination. Standard dispatch is via DHL Express or FedEx International Priority, with transit times of 3–7 business days to industrial hubs across Europe, the Middle East, Southeast Asia, and the Americas. Same-day dispatch is available for confirmed in-stock orders placed before 14:00 CST.

A 12-month warranty covers manufacturing defects from the date of shipment. Warranty replacement units are dispatched within 5 business days of receiving and inspecting the returned module. Technical support is provided by engineers with direct CENTUM VP commissioning experience, available via email and WhatsApp during business hours (UTC+8, Monday–Saturday).

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.