Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- GE
- Primary Part Number
- IC697CMM74
- Product Type
- PLC Communication Module
- Series / Family
- Fanuc
- Country of Origin
- US
- Catalog Category
- Communication
- Operating Temp.
- 0 °C to +60 °C
- Warranty
- 12 months from shipment date — replacement or full refund
GE IC697CMM741 Series 90-70 Dual-Protocol Ethernet LAN Interface Module: Backplane-Level Communication Architecture
The GE IC697CMM741 occupies a single slot in the Series 90-70 VME-based rack and functions as the primary Ethernet gateway between the PLC backplane and plant-floor IP networks. Its core role is to terminate two distinct protocol stacks — MMS (Manufacturing Message Specification, ISO 9506) and TCP/IP — on a single physical 10BASE-T / 10BASE-2 interface, eliminating the need for external protocol converters in SCADA-integrated control loops. In process industries where the Series 90-70 platform manages continuous-loop regulation, the IC697CMM741 provides the deterministic data path that allows supervisory systems to read register blocks, issue setpoint writes, and receive unsolicited event reports without interrupting the CPU scan cycle.
The module’s firmware arbitrates between MMS application-layer requests and raw TCP/IP socket traffic at the network stack level, maintaining separate connection tables for each protocol. This architecture means a Proficy iFIX or Cimplicity SCADA node can maintain an active MMS session for structured data exchange while a separate TCP/IP client — such as a historian or data concentrator — simultaneously polls floating-point process values via direct socket connections. Both sessions share the same physical Ethernet port without contention, because the IC697CMM741 handles session multiplexing internally rather than relying on the host CPU for protocol dispatch.
📦 Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Part Number | IC697CMM741 |
| Platform | GE Fanuc Series 90-70 PLC |
| Module Function | Ethernet LAN Interface — MMS & TCP/IP dual-protocol |
| Physical Interface | 10BASE-T (RJ-45) and 10BASE-2 (BNC) — selectable |
| Supported Protocols | MMS (ISO 9506), TCP/IP, ARP, ICMP |
| Backplane Bus | Series 90-70 VME-compatible backplane, 32-bit data path |
| Max Concurrent Connections | Up to 8 simultaneous MMS/TCP sessions |
| Rack Slot Requirement | 1 slot (any I/O slot in Series 90-70 rack) |
| Operating Voltage | +5 VDC via backplane (supplied by rack power supply) |
| Power Draw | Refer to GE Fanuc Series 90-70 System Manual GFK-0262 |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | −40 °C to +85 °C |
| Relative Humidity | 5 % to 95 % RH, non-condensing |
| Vibration Resistance | Per IEC 60068-2-6 (sinusoidal, 10–57 Hz, 0.075 mm amplitude) |
| EMC Immunity | Per EN 61000-4 series (ESD, EFT, surge, conducted RF) |
| Certifications | CE, UL, cUL (original GE Fanuc certification) |
| Firmware | Factory-loaded; field-upgradeable per GFK-1541 documentation |
| Form Factor | Single-slot Series 90-70 module, front-panel LED status indicators |
| Weight | Approx. 580 g |
| Warranty | 12 months from shipment date — replacement or full refund |
Hardware Logical Analysis
The IC697CMM741 implements a co-processor architecture: an onboard microprocessor handles all Ethernet frame processing, protocol stack execution, and session management independently of the Series 90-70 CPU. Communication with the host CPU occurs exclusively through a shared dual-port RAM (DPRAM) region mapped onto the VME backplane address space. This design isolates network-layer latency from the PLC scan cycle — a TCP retransmission event or MMS session negotiation does not extend the CPU sweep time, preserving deterministic loop execution at configured scan rates.
EMC Design: The module’s PCB layout separates the analog front-end (Ethernet magnetics and line driver circuitry) from the digital logic plane using a split ground pour with a single-point star connection. Transformer-coupled isolation on both 10BASE-T and 10BASE-2 interfaces provides 1,500 V galvanic isolation between the network cable and the module’s internal logic, attenuating common-mode noise induced by ground potential differences across large plant-floor cable runs — a frequent failure mode in heavy industrial environments with variable-frequency drives and large motor contactors operating nearby.
MMS Application Layer: The MMS stack on the IC697CMM741 implements the companion standard for SCADA/EMS communication as defined in ISO 9506-1 (service definition) and ISO 9506-2 (protocol specification). The module maintains a Virtual Manufacturing Device (VMD) model that maps Series 90-70 register addresses (%R, %AI, %AQ, %I, %Q memory types) to named MMS variables. This allows SCADA clients to reference process data by engineering-meaningful variable names rather than raw memory offsets, reducing integration engineering time and eliminating address-mapping errors during commissioning.
TCP/IP Socket Layer: Parallel to the MMS stack, the module supports raw TCP socket connections for applications that require direct register-block access without MMS overhead. The firmware implements a Modbus/TCP gateway function in certain firmware revisions, allowing Modbus-native HMI panels to communicate with the Series 90-70 CPU through the IC697CMM741 without additional protocol conversion hardware. Connection timeout and keepalive parameters are configurable via the Logicmaster 90-70 or Proficy Machine Edition configuration tool.
Redundancy Arbitration: In hot-standby CPU configurations (IC697CPU772 or IC697CPU781 pairs), the IC697CMM741 participates in the redundancy switchover sequence. The module maintains its Ethernet session table across a CPU switchover event, minimizing SCADA reconnection delays. Session persistence during switchover is governed by the TCP keepalive timer settings on the SCADA client — properly configured clients experience switchover as a brief data gap rather than a full connection loss.
System Integration Benefits
- Zero-impact network processing: Co-processor architecture offloads all Ethernet and protocol stack execution from the Series 90-70 CPU, preserving configured scan rates under peak network load without scan-time extension.
- Dual-protocol concurrency: MMS and TCP/IP sessions operate simultaneously on a single physical port, eliminating the need for separate communication modules or external protocol bridges in mixed-client environments.
- Galvanic isolation on both interfaces: 1,500 V transformer-coupled isolation on 10BASE-T and 10BASE-2 ports suppresses common-mode noise from ground loops, reducing nuisance communication faults in electrically noisy plant environments.
- VMD-based variable mapping: MMS Virtual Manufacturing Device model maps PLC memory directly to named SCADA variables, enabling tag-based engineering without manual address translation and reducing commissioning errors.
- Redundancy-aware session management: Session table persistence across hot-standby CPU switchover events minimizes SCADA reconnection overhead, maintaining supervisory visibility during fault-tolerant failover sequences.
- Configurable connection parameters: TCP keepalive intervals, MMS session timeouts, and connection limits are adjustable via standard GE configuration tools, allowing the module to be tuned for both high-frequency polling and low-bandwidth remote SCADA links.
- Diagnostic transparency via LED indicators: Front-panel LEDs provide real-time status for power, backplane communication, Ethernet link, and active session count — enabling field technicians to isolate faults at the module level without SCADA access.
- Firmware field-upgradeability: Onboard firmware is upgradeable via the backplane without module removal, allowing protocol enhancements and bug fixes to be applied during scheduled maintenance windows without rack disassembly.
- Broad rack compatibility: Installs in any I/O slot across all Series 90-70 rack sizes (IC697CHS750, IC697CHS782, IC697CHS790), with no slot-position restrictions, simplifying rack layout planning in constrained panel installations.
- Historian and data concentrator support: TCP/IP socket interface supports simultaneous connections from multiple data consumers — DCS historians, OPC servers, and data concentrators — without requiring dedicated communication modules for each client type.
Quality Assurance & Global Logistics
Every IC697CMM741 unit supplied through siemensplc.com is sourced from verified industrial channels and carries original GE Fanuc manufacturing traceability. Each module undergoes a structured pre-shipment verification sequence: physical authenticity inspection of PCB markings, GE Fanuc label integrity, and connector condition; functional power-on test in a Series 90-70 test rack confirming backplane communication and LED status; Ethernet port verification confirming 10BASE-T link establishment and frame transmission; and MMS/TCP-IP session test confirming successful protocol handshake with a reference SCADA node. Inspection records, Certificate of Conformance (COC), and high-resolution pre-shipment photographs are available for every unit on request.
Shipments originate from Xiamen, China, with export documentation including Commercial Invoice, Packing List, Country of Origin Declaration, and COC as standard. Logistics partners include DHL Express, FedEx International Priority, and SF Express for domestic China delivery. In-stock units ship within 1–3 business days of order confirmation. Express international delivery reaches most destinations in Asia-Pacific, the Middle East, Europe, and the Americas within 3–7 business days. All modules are packed in anti-static ESD bags within foam-lined cartons with moisture-barrier outer packaging, conforming to IPC/JEDEC J-STD-033 handling requirements for electrostatic-sensitive devices. Bulk order sea freight consolidation is available on request. A 12-month warranty against defects in materials and workmanship applies to every unit from the date of shipment.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
📍 Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.