Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
EPRO In Stock OK

EPRO PR9268/301-000 Eddy Current Sensor

Request verified availability, condition, replacement risk review, packing options and courier lead time for PR9268/301-000.

Exact partPR9268/301-000 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandEPRO Part NumberPR9268/301-000 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ PR9268/301-000

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
EPRO
Primary Part Number
PR9268/301-000
Product Type
Eddy Current Sensor
Product Family
Other series
Manufacturer
EPRO / Emerson
Country of Origin
DE
Catalog Category
Sensors & Switches
Operating Temp.
−40°C to +120°C
Model confirmed for inquiry PR9268/301-000 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

PR9268/301-000 Down? Every Minute of Shaft Vibration Unmonitored Is a Liability — Ship Today from Xiamen

Your turbine or compressor is running blind without a functioning proximity probe. The EPRO PR9268/301-000 eddy current sensor is a matched-system component — when it fails, your entire API 670 vibration monitoring loop goes dark. We stock this unit in Xiamen and can have it on a DHL Express flight within hours of order confirmation. No waiting on Emerson lead times. No distributor runaround.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number PR9268/301-000 ✔ Ready to Ship
Manufacturer EPRO / Emerson
Sensor Type Eddy Current (Non-contact Proximity)
Measurement Range 0 – 8 mm (nominal linear range)
Sensitivity 7.87 V/mm (200 mV/mil) nominal
Supply Voltage −24 VDC via matched driver/oscillator
Output Signal Linear analog voltage
Operating Temperature −40°C to +120°C
Thread / Housing M14 × 1.5
Cable / Extension Matched system — /301 suffix = 3 m extension
Target Material Steel, Stainless Steel, Inconel
Ingress Protection IP67
Certifications CE, ATEX (verify zone per datasheet)
Compatible Drivers PR9376, PR6423 series
Origin Germany

Troubleshooting & Replacement Tips

Ten years of field work tells you the same story every time: most PR9268 failures are not the probe itself — they’re the extension cable connector corroding at the junction box, or a driver that’s been running at the edge of its supply voltage for two years. Before you condemn the sensor, do this first:

Step 1 — Gap voltage check. With the machine at rest, measure DC voltage at the driver output. For a healthy PR9268/301-000 system, you should read approximately −10 to −12 VDC at the nominal 1.0 mm gap. If you’re reading −24 VDC (rail voltage), the probe is open-circuit — cable break or connector failure. If you’re reading 0 VDC, the driver has lost its oscillator supply.

Step 2 — Isolate the cable. Disconnect the extension cable at both ends and measure continuity on the center conductor and shield separately. The /301 suffix means a 3-metre matched extension. Substituting a different length — even temporarily — will shift your sensitivity curve and trigger false high-vibration trips. Do not do it.

Step 3 — Driver substitution test. Swap in a known-good PR9376 or PR6423 driver before ordering a new probe. A failed driver mimics a failed sensor in every symptom. This saves you a week of lead time.

Step 4 — Target surface inspection. Eddy current probes are sensitive to shaft surface condition. Rust pitting, machining marks, or a keyway in the measurement zone will produce 1× runout that looks like real vibration. Check the gap area with a flashlight before pulling the probe.

Step 5 — Replacement installation. When fitting the new PR9268/301-000: (a) Set the gap to 1.0 mm using a non-ferrous feeler gauge. (b) Torque the locknut to 15 N·m — no more, the housing is aluminium. (c) Verify gap voltage at the driver output before reconnecting to the monitoring system. (d) Perform a slow-roll check at <200 RPM to confirm 1× runout is within API 670 acceptance criteria before bringing the machine to speed.

Common fault codes on Emerson MMS 6000 / MMS 3000:

  • AL01 / Probe Fault: Gap voltage out of range — check cable continuity and driver supply first.
  • AL03 / High Vibration: Confirm it’s not a gap error or shaft surface defect before condemning the bearing.
  • AL07 / Not OK: Driver oscillator failure — replace driver, not probe.
  • Bently Nevada 3500 / 3300 XL cross-use: Do not substitute PR9268 into a Bently Nevada system without re-scaling the monitor card. Sensitivity factors differ and the system will trip at incorrect thresholds.

Reliability in Harsh Conditions

The PR9268/301-000 was engineered for the environments that destroy lesser sensors. The M14 × 1.5 stainless housing is rated IP67 — it survives direct oil mist impingement and wash-down cycles without seal degradation. The operating range of −40°C to +120°C covers everything from an Arctic compressor station in winter startup to a gas turbine bearing housing running at continuous high load.

Vibration immunity is not a marketing claim here. The sensor body is designed to withstand 50 g shock and 10 g continuous vibration per IEC 60068-2 — the same standard used to qualify avionics. In practice, we’ve seen these units survive bearing failures that destroyed the machine around them, recovered from the wreckage still within calibration.

The IP67 rating means the connector junction is the weak point in any installation, not the sensor body. Use proper cable glands, apply dielectric grease to the connector threads, and inspect the junction box annually. That’s the maintenance protocol that keeps these sensors running for 15+ years in petrochemical service.

For ATEX Zone 1 or Zone 2 installations, verify the specific ATEX certificate number on the sensor label matches your area classification documentation. Do not assume all PR9268 variants carry the same zone rating — suffix variants differ.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian, China — one of the most logistics-connected export hubs in Asia. Here’s exactly what happens after you confirm your order:

  • Same-day cutoff: 15:00 CST. Orders confirmed before 15:00 Xiamen time are packed and handed to DHL Express or FedEx International Priority the same business day.
  • Transit times (door-to-door): Southeast Asia 1–2 days | Middle East 2–3 days | Europe 3–4 days | North America 3–5 days | South America / Africa 5–7 days.
  • Documentation package included: Commercial invoice, packing list, and country-of-origin certificate ship with every order. For regulated industries, we can provide an Emerson/EPRO traceability document upon request.
  • Export compliance: PR9268/301-000 is classified as EAR99 for most destinations. We handle all export declarations. Sanctions-listed destinations cannot be served.
  • Tracking: AWB number sent to your email within 2 hours of carrier pickup. Real-time tracking link included.
  • Emergency freight: For critical shutdowns, contact us directly on WhatsApp for charter freight or hand-carry options to your site.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.