SST SST-ESR2-CPX-P Communication Gateway – ESR2 Series
Request verified availability, condition, replacement risk review, packing options and courier lead time for SST-ESR2-CPX-P.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- SST
- Primary Part Number
- SST-ESR2-CPX-P
- Product Type
- Industrial Communication Gateway
- Series / Family
- ESR2 Series
- Manufacturer
- SST (Molex / Woodhead)
- Country of Origin
- United States
- Catalog Category
- Communication
- Operating Temp.
- 0 °C to +60 °C
- Warranty
- 12 months from date of shipment
SST SST-ESR2-CPX-P: ControlNet-to-PROFIBUS-DP Protocol Bridge in Industrial Control Architectures
The SST-ESR2-CPX-P, manufactured by SST (a Molex company), is a backplane-resident communication gateway engineered to establish deterministic data exchange between an Allen-Bradley ControlNet scanner and a PROFIBUS-DP master/slave field network. Unlike software-based OPC bridges or external protocol converters, the ESR2-CPX-P integrates directly into the ControlLogix or CompactLogix chassis backplane, eliminating the latency penalties and single-point-of-failure risks associated with PC-hosted middleware solutions.
In a typical control loop, the module occupies a standard 1756-series chassis slot and presents itself to the ControlNet scanner as a scheduled connection node. On the PROFIBUS side, it operates as a Class 1 DP master, polling up to 125 slave addresses at baud rates from 9.6 kbps to 12 Mbps. The internal data mapping engine translates ControlNet scheduled I/O data tables directly into PROFIBUS-DP cyclic data frames — a process that executes within the module’s onboard ASIC without consuming PLC scan time. This architecture ensures that PROFIBUS cycle jitter does not propagate into the ControlNet scheduled bandwidth, preserving the deterministic timing guarantees that safety-rated and motion-critical applications depend on.
The module’s configuration is handled through RSNetWorx for ControlNet in conjunction with the SST Configuration Utility, which generates an EDS-compatible device profile importable into Studio 5000 / RSLogix 5000. Once the Add-On Profile (AOP) is loaded, the PLC program accesses PROFIBUS slave I/O data through standard controller tags — no custom ladder logic or message instructions are required for cyclic data exchange. Acyclic PROFIBUS-DP V1 services (Class 2 master functions) are accessible via explicit MSG instructions for parameter read/write operations on intelligent field devices such as variable-frequency drives and smart transmitters.
From a system architecture standpoint, the SST-ESR2-CPX-P is particularly valuable in brownfield integration projects where an existing PROFIBUS-DP field network — wired with Type A shielded twisted-pair cable and populated with certified DP slaves — must be absorbed into a ControlNet-based supervisory architecture without rewiring or replacing field instrumentation. A single ESR2-CPX-P module can manage the full PROFIBUS segment, consolidating what would otherwise require multiple point-to-point serial converters into a single, diagnostically transparent chassis module.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Part Number | SST-ESR2-CPX-P |
| Manufacturer | SST (Molex / Woodhead) |
| Series | ESR2 |
| Module Function | ControlNet Scheduled Node ↔ PROFIBUS-DP Class 1 Master |
| Backplane Interface | ControlLogix 1756 / CompactLogix 1769 chassis backplane |
| ControlNet Protocol | ODVA ControlNet, coaxial or fiber media |
| PROFIBUS Protocol | PROFIBUS-DP V0 / V1 (EN 50170 / IEC 61158) |
| PROFIBUS Baud Rates | 9.6 kbps, 19.2 kbps, 45.45 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps |
| Max PROFIBUS Slave Addresses | 125 (addresses 0–126, address 126 reserved) |
| Max I/O Data per Slave | 244 bytes input / 244 bytes output (DP V0 cyclic) |
| Acyclic Services | PROFIBUS-DP V1 Class 2 master (parameter read/write via MSG) |
| Configuration Tools | RSNetWorx for ControlNet v4.0+; SST Configuration Utility; Studio 5000 AOP |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | −40 °C to +85 °C |
| Relative Humidity | 5% to 95% non-condensing |
| Power Supply | Backplane-powered (1756 chassis); refer to OEM datasheet for exact mA draw |
| Certifications | CE (EMC Directive 2014/30/EU), UL Listed, PROFIBUS Certified (PI), RoHS 2011/65/EU |
| Country of Origin | United States |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
The ESR2-CPX-P’s internal architecture separates the ControlNet physical layer interface from the PROFIBUS-DP master controller through a dual-port shared memory (DPSM) structure. The ControlNet ASIC handles scheduled and unscheduled bandwidth allocation independently of the PROFIBUS master state machine, which runs on a dedicated embedded processor. This dual-processor topology means that a PROFIBUS bus fault — such as a slave timeout or cable break — generates a diagnostic flag in the shared memory region without stalling the ControlNet scheduled connection. The PLC’s I/O scan continues to receive valid (though fault-flagged) data, allowing the application program to execute its fault-handling logic rather than entering a communication fault state that would require a controller restart.
The PROFIBUS-DP master controller implements the standard DP state machine (Power-On → Offline → Stop → Clear → Operate) with configurable watchdog timers per slave address. The watchdog timeout values are set during configuration and stored in non-volatile flash memory on the module, ensuring that the PROFIBUS network resumes its pre-fault operating state automatically after power cycling without requiring a re-download from the PLC.
On the EMC side, the module’s PCB layout routes the PROFIBUS RS-485 differential pair through an isolated transceiver with ±15 kV ESD protection on the data lines. The backplane connector side uses optocoupler isolation between the chassis backplane logic ground and the PROFIBUS cable shield ground, preventing ground loop currents — a common source of intermittent communication errors in long cable runs through electrically noisy environments such as motor control centers and variable-speed drive panels. The module’s metal housing provides additional shielding against radiated emissions, and the chassis slot grounding scheme bonds the module frame to the chassis earth rail, meeting the requirements of IEC 61000-4-4 (electrical fast transient) and IEC 61000-4-5 (surge immunity) test levels applicable to industrial control equipment.
The internal data mapping table supports both direct (1:1 byte-mapped) and structured (tag-based) I/O mapping modes. In structured mode, the module’s configuration utility generates a controller tag structure that mirrors the PROFIBUS GSD file’s I/O module definitions, allowing the PLC programmer to reference individual process values by engineering name rather than raw byte offset — a significant reduction in commissioning time and a measurable improvement in program readability for long-term maintenance teams.
System Integration Benefits
- Zero PLC Scan-Time Overhead: All PROFIBUS-DP cyclic polling executes on the module’s onboard processor. The PLC backplane exchange transfers pre-assembled I/O data images, not raw PROFIBUS frames, keeping the controller’s task execution time independent of PROFIBUS segment size or slave count.
- Deterministic ControlNet Scheduling: The module participates in the ControlNet scheduled bandwidth as a standard NUT (Network Update Time) node. PROFIBUS data is refreshed within the configured NUT interval, providing bounded latency guarantees that unscheduled Ethernet-based alternatives cannot match in time-critical motion or safety interlock applications.
- Unified Diagnostic Visibility: Slave-level PROFIBUS diagnostics (DP standard diagnostics, device-specific diagnostics, and extended diagnostics) are mapped into the controller tag space and accessible via RSLogix 5000 / Studio 5000 online monitoring without requiring a separate PROFIBUS diagnostic tool on the network.
- DP V1 Acyclic Parameter Access: Variable-frequency drives, smart positioners, and intelligent transmitters that support PROFIBUS-DP V1 can be parameterized and read back via standard MSG instructions from the PLC program, enabling online drive parameter adjustment and predictive maintenance data collection without interrupting cyclic process control.
- Brownfield Compatibility: The module accepts any PROFIBUS-DP V0/V1 certified slave device regardless of manufacturer. Existing GSD files are imported directly into the SST Configuration Utility, preserving the engineering investment in the original PROFIBUS network design.
- Redundancy-Ready Architecture: When used in conjunction with ControlNet redundant media (dual coax or fiber rings), the ESR2-CPX-P maintains its ControlNet connection through media switchover events without dropping the PROFIBUS master state machine, preventing nuisance slave faults during network reconfiguration.
- Scalable I/O Capacity: A single module manages up to 125 PROFIBUS slave addresses, each with up to 244 bytes of cyclic I/O data. This consolidates what would otherwise require multiple gateway devices into a single chassis slot, reducing panel space, wiring complexity, and per-node licensing costs.
- Studio 5000 AOP Integration: The Add-On Profile provides a graphical faceplate for online diagnostics, slave status monitoring, and module configuration review directly within the Studio 5000 environment, eliminating the need to switch between configuration tools during commissioning or troubleshooting.
Quality Assurance & Global Logistics
Every SST-ESR2-CPX-P unit supplied by siemensplc.com is sourced through verified industrial distribution channels with full traceability documentation. Physical inspection covers label integrity, PCB revision markings, connector pin condition, and housing for any evidence of remarking or tampering. Functional verification confirms power-on LED sequencing and communication port response against OEM-published diagnostic behavior. Units are packed in anti-static ESD-safe bags with desiccant, placed in rigid foam-lined cartons rated for international air freight handling.
Shipments originate from our warehouse in Xiamen, China. Standard export documentation — commercial invoice, packing list, and HS code declaration (HS 8537.10 as applicable) — is prepared for every order to facilitate smooth customs clearance in the destination country. International express delivery via DHL Express, FedEx International Priority, or UPS Worldwide Expedited provides door-to-door tracking with typical transit times of 3–7 business days to major industrial hubs in Europe, North America, Southeast Asia, and the Middle East. For time-critical plant shutdowns or emergency maintenance situations, same-day dispatch is available for in-stock units when orders are confirmed before the daily cut-off time. Volume orders and project-based procurement with staged delivery schedules are accommodated — contact the sales team with your full BOM and project timeline for a consolidated logistics proposal.
All units carry a 12-month warranty from the date of shipment. Dead-on-arrival (DOA) units are replaced or refunded within 30 days of delivery upon submission of photographic or video evidence of the fault condition. Warranty claims do not require return of the unit to the original OEM — our team manages the replacement process directly, minimizing downtime for your maintenance operation.
Contact Information
📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
📍 Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.