Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
BOSCH Rexroth In Stock OK

Bosch Rexroth VCP05.1BSN.PB-NN-PW HMI Operator Terminal

Request verified availability, condition, replacement risk review, packing options and courier lead time for PB-NN-PW.

Exact partPB-NN-PW RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBOSCH Rexroth Part NumberPB-NN-PW ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ PB-NN-PW

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
BOSCH Rexroth
Primary Part Number
PB-NN-PW
Product Type
HMI Operator Terminal
Series / Family
VCP05 Series
Manufacturer
Bosch Rexroth
Country of Origin
DE
Catalog Category
HMI Panels
Model confirmed for inquiry PB-NN-PW Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

VCP05.1BSN.PB-NN-PW Down? Every Minute of Downtime Costs You Money — We Ship Today

Your line is stopped. The VCP05.1BSN.PB-NN-PW is dead — blank screen, no comms, operators standing idle. You’ve already pulled the unit, confirmed the fault, and now you need a replacement in hand before the next shift. That’s exactly the scenario we built this stock position for. We hold verified Bosch Rexroth VCP05.1BSN.PB-NN-PW units in Xiamen, pre-inspected and ready to dispatch via DHL or FedEx within hours of order confirmation. No lead-time negotiation. No waiting on a distributor’s back-order queue. You call, we ship.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Part Number VCP05.1BSN.PB-NN-PW  ✔ Ready to Ship
Manufacturer Bosch Rexroth
Series VCP05
Device Type Compact HMI Operator Terminal
Fieldbus Interface PROFIBUS-DP (onboard, PB suffix)
Display Monochrome graphic LCD, membrane keypad
Supply Voltage 24 V DC (PW suffix)
Mounting Style Panel cut-out, front-flush, IP65 front face
Protection Rating IP65 (IEC 60529, panel-mounted with gasket)
Communication Standard IEC 61158 / EN 50170 PROFIBUS-DP
Country of Origin Germany
Condition New OEM / Surplus New — confirmed at order
Stock Status ✔ In Stock — Xiamen Warehouse
Dispatch Lead Time Same day / next business day

Troubleshooting & Replacement Tips

Ten years of field calls on Rexroth VCP05 panels teach you the same failure patterns every time. Before you condemn the unit, run through this checklist — but if you’ve already confirmed hardware death, skip straight to the swap procedure below.

Common Failure Modes on VCP05.1BSN.PB-NN-PW:

  • Blank display, power LED off: Check 24 V DC supply at the panel connector first. A failed DIN-rail PSU or a blown fuse on the 24 V rail kills the panel before the backlight even fires. Measure at the terminal, not at the breaker.
  • Display on, PROFIBUS fault / BF LED solid red: The DP address on the replacement unit must match the original exactly. VCP05 panels store the DP node address in non-volatile memory. If you’re swapping to a unit previously configured for a different address, re-enter the DP address via the panel’s setup menu before connecting to the bus. A bus address conflict will take down adjacent DP slaves — the whole segment goes dark.
  • Panel boots, shows Project not found or blank project screen: The HMI project lives in the panel’s internal flash. A replacement unit ships without your project. Reload via IndraWorks or WinStudio over the serial or Ethernet service port before the panel is operational. Keep a current project backup on your engineering laptop — always.
  • Intermittent comms, DP timeouts under vibration: Inspect the PROFIBUS-DP D-Sub 9-pin connector at the panel. The locking screws on VCP05 connectors back out under sustained vibration. Re-torque to spec and apply thread-lock compound. Verify bus termination resistors are active only at the physical ends of the DP segment.
  • Firmware mismatch after swap: If your IndraControl host PLC expects a specific GSD revision from the VCP05, a unit with older firmware may generate a Module mismatch alarm. Check the firmware version label on the unit’s rear housing and compare against your PLC’s DP configuration. Rexroth firmware updates are available via the IndraWorks service tool.
  • Touchscreen unresponsive: Recalibrate the touch matrix via the panel’s service menu (hold the key combination on boot per VCP05 operating manual R911343624). A replacement unit needs recalibration if a protective overlay is fitted.

Hot-Swap Procedure — Condensed Field Steps:

  1. De-energise the panel: isolate 24 V DC supply. Do NOT pull the PROFIBUS connector live — DP bus disturbance will fault the entire segment.
  2. Disconnect PROFIBUS-DP D-Sub connector and 24 V power connector. Label both.
  3. Release panel mounting clamps from rear. Slide unit forward out of cut-out.
  4. On the replacement unit: set DP node address to match original via setup menu — power the unit standalone first to do this.
  5. Install replacement unit into cut-out. Torque mounting clamps evenly to prevent gasket distortion and IP65 compromise.
  6. Reconnect 24 V DC supply. Reconnect PROFIBUS-DP connector — verify termination plug status.
  7. Download HMI project from engineering laptop via service port.
  8. Energise bus. Confirm DP status LED goes green. Acknowledge any PLC alarms. Verify all screen pages navigate correctly before handing back to operators.

Reliability in Harsh Conditions

The VCP05.1BSN.PB-NN-PW was engineered for the factory floor, not the office. Bosch Rexroth’s industrial qualification testing for this series covers the conditions that destroy lesser panels within months.

  • Vibration and Mechanical Shock: Qualified per IEC 60068-2-6 sinusoidal vibration and IEC 60068-2-27 mechanical shock. The sealed membrane keypad and solid-state display have no moving parts to fatigue. Panel cut-out mounting distributes mechanical load across the enclosure door rather than concentrating stress at connector points.
  • Thermal Range: Rated for the full industrial ambient temperature range. The fanless design eliminates the single most common cause of panel failure in hot environments — a seized cooling fan that causes thermal shutdown and eventual board-level damage from sustained over-temperature.
  • Humidity and Condensation: IP65 front face prevents ingress of water jets and dust. Internal conformal coating on the PCB provides additional protection against condensation in environments with rapid temperature cycling — common in food processing and outdoor enclosures.
  • EMC Immunity: CE-marked per EU EMC Directive. Designed to operate in the electrically noisy environment of a PROFIBUS-DP network running alongside variable-frequency drives, contactors, and high-current motor cables. Proper cabinet grounding and shielded DP cable remain the installer’s responsibility — the panel holds its end of the bargain.
  • Chemical Resistance: Front membrane and housing material resist common industrial cleaning agents, cutting fluids, and hydraulic oil splash. Wipe down with isopropyl alcohol for routine cleaning. Avoid prolonged contact with strong solvents.

Global Express Logistics

Our Xiamen warehouse is positioned specifically for fast international dispatch. Xiamen Gaoqi International Airport has direct freight connections to DHL and FedEx international hubs, which means your VCP05.1BSN.PB-NN-PW moves from our shelf to the air freight network without domestic relay delays.

  • Order cut-off: Orders confirmed with payment before 14:00 CST ship same business day. Orders after cut-off ship next morning.
  • Packaging: Anti-static bag, foam-lined carton, humidity indicator card, silica gel desiccant. The unit arrives at your site in the same condition it left our warehouse — regardless of whether it transits through three continents.
  • Export documentation: Commercial invoice, packing list, and certificate of origin prepared for every international shipment. HS code declared correctly to avoid customs holds. For destinations requiring additional import permits, advise us at order stage.
  • DHL Express Worldwide: Typical transit 2–4 business days to Europe, North America, Southeast Asia, and the Middle East. Real-time tracking from pickup to delivery.
  • FedEx International Priority: Available as an alternative carrier for destinations where FedEx has stronger last-mile coverage. Transit times comparable to DHL.
  • Freight consolidation: Ordering multiple line items for a larger BOM? We consolidate into a single shipment to reduce per-unit freight cost. Submit your full parts list to [email protected] for a consolidated freight quote.
  • Emergency courier: For genuine production-critical situations, hand-carry or next-flight-out courier service is available to virtually any destination. Contact us via WhatsApp for fastest response.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.