Honeywell CC-SDOR01 51308380-175 Digital Output Relay – Experion PKS C300
Request verified availability, condition, replacement risk review, packing options and courier lead time for CC-SDOR01.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Honeywell
- Primary Part Number
- CC-SDOR01
- Product Type
- Digital Output Module
- Series / Family
- Experion PKS
- Manufacturer
- Honeywell Process Solutions
- Country of Origin
- US
- Catalog Category
- I/O Modules
- Warranty
- 12 months from date of shipment
- Compliance
- CE marked; UL listed (verify revision against official Honeywell datasheet)
Honeywell CC-SDOR01 51308380-175 — Relay-Type Digital Output Interface for Experion PKS C300 DCS
The Honeywell CC-SDOR01 (reference number 51308380-175) is a relay-type digital output module engineered for the Experion PKS C300 distributed control system. Within a live DCS architecture, the digital output layer is the final command boundary between the controller’s logic execution and physical field devices — solenoid valves, motor contactors, alarm annunciators, and interlock relays. The CC-SDOR01 fulfills this role using electromechanical relay contacts rather than solid-state switching elements, a deliberate design choice that delivers true galvanic isolation, broad load compatibility, and inherent fail-safe behavior under power-loss conditions.
In the C300 I/O subsystem, the CC-SDOR01 mounts directly into the C300 I/O chassis and communicates with the C300 controller over the C300 I/O Link — a deterministic, high-speed serial bus that maintains scan-cycle synchronization across all attached I/O modules. Each output channel’s commanded state is written by the C300 controller at every scan cycle, and the module’s onboard firmware latches the relay coil drive accordingly. This architecture ensures that output state transitions are bounded by the controller’s configured scan period, providing predictable actuation timing for interlock and sequencing logic.
The relay contact design of the CC-SDOR01 accommodates both AC and DC load circuits on the same module, without requiring separate module variants for different field voltage classes. This load-agnostic characteristic simplifies spare-parts inventory management in facilities where field devices span multiple voltage standards — a common condition in brownfield expansions and multi-vendor plant environments. The dry-contact output configuration also means the module does not source field power; the field circuit is energized by an external supply, which eliminates the risk of module-side power faults propagating into the field wiring network.
Honeywell’s Experion PKS platform is deployed across refineries, LNG terminals, chemical reactors, power generation facilities, and water treatment plants globally. The CC-SDOR01 is a standard catalog I/O module within this ecosystem, meaning replacement units are interchangeable without controller reconfiguration — provided the I/O chassis slot assignment and tag database remain consistent. This plug-compatible replacement characteristic is operationally significant: maintenance teams can execute module swaps during scheduled outages without requiring control system engineers to modify the application database.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Part Number | CC-SDOR01 |
| Reference / Order Number | 51308380-175 |
| Module Classification | Digital Output — Relay Type |
| Platform Compatibility | Honeywell Experion PKS C300 I/O Subsystem |
| Output Contact Type | Dry contact (Form A / SPST-NO), electromechanical relay |
| Isolation Method | Galvanic isolation — field circuit fully isolated from system bus |
| Load Compatibility | AC and DC loads; no internal field power sourcing |
| Chassis Interface | C300 I/O chassis direct-mount; communicates via C300 I/O Link |
| Module Form Factor | C300 I/O chassis-mount card |
| Approximate Weight | 380 g |
| Compliance | CE marked; UL listed (verify revision against official Honeywell datasheet) |
| Manufacturer | Honeywell Process Solutions |
| Country of Origin | United States |
| Warranty | 12 months from date of shipment |
All electrical parameters should be verified against the current Honeywell CC-SDOR01 product datasheet prior to installation. Specifications are subject to hardware revision.
Hardware Logical Analysis
The CC-SDOR01’s relay output architecture addresses several hardware-level engineering constraints that solid-state alternatives cannot resolve without additional external components.
Galvanic Isolation Mechanism: The relay coil and contact circuit are physically separated by an air gap and dielectric barrier. There is no conductive path between the C300 I/O bus side and the field wiring side under any normal operating condition. This eliminates common-mode voltage coupling and ground loop formation — failure modes that frequently corrupt analog measurements and trigger spurious digital transitions in high-noise industrial environments. The isolation withstand voltage rating (verify in datasheet) ensures the module survives transient overvoltages generated by inductive load switching without damage to the control system backplane.
EMC Design Considerations: Relay coil drive circuits on the CC-SDOR01 incorporate flyback suppression to clamp the inductive kickback voltage generated when the coil is de-energized. Without this suppression, each relay de-energization event would generate a high-voltage transient on the module’s internal power rail, potentially coupling into adjacent I/O channels or the C300 I/O Link bus. The suppression network limits this transient to within the module’s rated operating voltage envelope, preserving signal integrity across the I/O chassis.
Contact State Latching Under Power Loss: Electromechanical relays are inherently de-energize-to-open devices. When the CC-SDOR01 loses its coil drive signal — whether due to a commanded OFF state, a controller fault, or a power supply interruption — the relay contacts open. For normally-open output circuits driving fail-safe actuators (spring-return valves, de-energize-to-trip solenoids), this behavior aligns with the process safety requirement without requiring additional external safety relays. This is a fundamental advantage over solid-state outputs, which may latch in an indeterminate state during power transients.
I/O Link Communication Determinism: The C300 I/O Link is a time-division multiplexed serial bus. The CC-SDOR01’s onboard microcontroller receives output data frames from the C300 controller at each scan cycle boundary and immediately updates the relay coil drive register. The latency between the controller writing an output value and the relay contact changing state is bounded by the I/O Link cycle time plus the relay mechanical operate time — a deterministic, measurable quantity that can be factored into interlock response time calculations for SIL verification studies.
System Integration Benefits
- Zero-Configuration Replacement: The CC-SDOR01 is a catalog-standard C300 I/O module. Replacing a failed unit requires no controller database modification — the new module assumes the slot’s tag assignments automatically upon power-up, provided the I/O chassis slot address is unchanged.
- Deterministic Output Latency: Output state transitions are bounded by the C300 scan period and relay operate time, enabling accurate interlock response time budgeting for SIL-rated loop design and verification.
- Broad Field Device Compatibility: Dry-contact relay outputs interface directly with AC solenoid valves, DC motor contactors, alarm annunciators, and pilot relay coils without intermediate signal converters or isolators.
- Diagnostic Transparency: The Experion PKS system monitors CC-SDOR01 module health via the C300 I/O Link. Module faults, communication failures, and output discrepancies are reported to the Experion operator station with alarm prioritization, reducing mean time to diagnose (MTTD).
- Fail-Safe Output Behavior: Relay de-energize-to-open characteristic aligns with standard process safety design conventions, reducing the need for external safety relay modules in fail-safe output circuits.
- Mixed Voltage Field Wiring: A single module type handles both AC and DC field circuits, simplifying spare-parts standardization and reducing the number of distinct module SKUs required in the maintenance inventory.
- Hot-Swap Maintenance: The C300 I/O subsystem supports online module replacement. The CC-SDOR01 can be removed and reinserted while the chassis remains powered, minimizing process disruption during corrective maintenance.
- Brownfield Integration Compatibility: The module’s standard C300 I/O chassis interface and catalog part number ensure compatibility with existing Experion PKS installations across all supported software revisions, simplifying lifecycle management in long-running plant assets.
Quality Assurance & Global Logistics
Every CC-SDOR01 unit supplied by siemensplc.com is sourced through verified supply channels and subjected to a structured pre-shipment inspection protocol. Physical examination covers PCB condition, connector integrity, label authenticity, and date code consistency against Honeywell’s manufacturing records. Part number and revision markings are cross-checked to confirm the unit matches the ordered specification before packaging.
Units are packed in anti-static shielding bags, placed in foam-lined cartons with moisture-barrier desiccant, and sealed for international transit. This packaging standard is maintained regardless of shipment destination or carrier selection.
Shipments originate from our warehouse in Xiamen, China — a major international logistics hub with direct access to DHL Express, FedEx International Priority, UPS Worldwide Express, and consolidated freight forwarding services. Standard express delivery to major industrial centers in Southeast Asia, the Middle East, Europe, and the Americas typically completes within 3–7 business days from shipment date. Expedited same-day dispatch is available for in-stock units when orders are confirmed before the daily cutoff.
Full export documentation is provided as standard: commercial invoice, packing list, and certificate of origin. Additional documents — including MSDS, test reports, or customs pre-clearance paperwork — are available upon request. All units carry a 12-month warranty from the date of shipment, covering defects in materials and workmanship under normal operating conditions.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.