Siemens 6SW1701-0DA14V98113-A1680-A1-4.8 Drive Control Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6SW1701-0DA14V98113-A1680-A1-4.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 6SW1701-0DA14V98113-A1680-A1-4
- Product Type
- Drive Control Module
- Series / Family
- SIMOVERT
- Manufacturer
- Siemens AG
- Country of Origin
- DE
- Catalog Category
- Motor Drives
- Operating Temp.
- 0°C to +55°C
- Compliance
- CE, UL, RoHS
Siemens 6SW1701-0DA14V98113-A1680-A1-4.8 — Stop the Clock on Your Downtime
Every minute a SIMOVERT drive sits dead on the cabinet floor, your production line is bleeding money. Whether it’s a steel mill conveyor locked up at 3 AM or a paper machine tripping on a Monday morning shift change, the 6SW1701-0DA14V98113-A1680-A1-4.8 is the exact card you need — and we have it on the shelf right now in Xiamen, ready to move.
This is not a lead-time quote. This is not a “check back in 8 weeks.” We stock verified, original Siemens SIMOVERT drive control modules specifically because procurement timelines don’t survive unplanned outages. Our warehouse team pulls, inspects, and packs within hours of order confirmation. DHL and FedEx Express lanes are pre-arranged. Your replacement is in the air before your maintenance team finishes writing the incident report.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | 6SW1701-0DA14V98113-A1680-A1-4.8 |
| Manufacturer | Siemens AG |
| Series | SIMOVERT — Variable Speed Drive Control Platform |
| Module Function | Drive Control / PLC Interface Board |
| Mounting | DIN Rail / Drive Cabinet Slot |
| Communication | PROFIBUS-DP, SIMOLINK |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -25°C to +70°C |
| Protection Rating | IP20 |
| Compliance | CE, UL, RoHS |
| Country of Origin | Germany |
| Stock Status | ✔ Ready to Ship — Xiamen Warehouse |
| Lead Time | Same-day dispatch on confirmed orders before 15:00 CST |
Troubleshooting & Replacement Tips
The 6SW1701-0DA14V98113-A1680-A1-4.8 sits at the heart of the SIMOVERT control architecture. When it fails, the drive typically throws one of the following fault codes before going dark:
- F002 / F003 — Internal processor watchdog timeout. The control board has lost its execution cycle. Power cycling won’t fix it; the board itself is gone.
- F023 — Communication loss between the control card and the power section. Check the ribbon cable first, but if the cable is intact, the control board’s PROFIBUS interface has failed.
- F041 — Parameter memory checksum error. The onboard EEPROM has corrupted. A replacement board will come with factory defaults; you’ll need to reload your parameter set from a backup or re-commission manually.
- A501 / A502 — Persistent alarm states that don’t clear after fault reset. Often a sign the control board’s analog input conditioning circuitry has drifted beyond tolerance.
Replacement procedure — field notes:
- Before pulling the old board, photograph the DIP switch positions and note the firmware version displayed on the operator panel (if still readable). The 6SW1701 series uses onboard DIP switches to configure node address for PROFIBUS and to set the drive’s operating mode. Mismatched switch positions after swap will cause immediate F023 on power-up.
- Discharge the DC bus fully before opening the cabinet — SIMOVERT drives hold significant capacitor charge even after mains isolation. Use a discharge resistor, not a multimeter probe.
- The control board connector is keyed but the locking tab is fragile on aged units. Pull straight out; do not lever.
- On power-up with the new board, the drive will enter parameter initialization mode. If your system uses a SIMATIC S7 PLC with a GSD file for PROFIBUS configuration, verify the GSD version matches the firmware on the replacement board. Firmware mismatch here is the single most common cause of failed swap-outs in the field.
- If the original board’s firmware version is not readable, connect a PC with STARTER or SCOUT software via the USS/PROFIBUS interface and read the firmware string from the drive’s identification register before decommissioning.
- After parameter restore, run a no-load test cycle before reconnecting the mechanical load. Verify speed reference tracking and current feedback signals are within spec.
Reliability in Harsh Conditions
SIMOVERT control boards are not office electronics. The 6SW1701-0DA14V98113-A1680-A1-4.8 is built to survive the kind of environment that destroys consumer-grade hardware in weeks.
The PCB uses conformal coating on signal-layer traces, providing resistance to condensation and airborne contaminants common in paper mills, chemical plants, and coastal installations. The onboard power supply section is designed to handle input voltage fluctuations typical of industrial bus systems — brownouts, switching transients, and harmonic distortion from nearby heavy loads don’t cause nuisance trips.
Vibration tolerance is validated to IEC 60068-2-6 standards, covering the 5–150 Hz frequency range at 1g acceleration — relevant for installations on or near rotating machinery, compressor skids, or mobile equipment. Shock resistance per IEC 60068-2-27 covers the kind of mechanical impulse that happens when a nearby machine trips hard and the cabinet shakes.
Thermal management is passive on the control board itself, relying on the drive cabinet’s forced-air cooling. Operating ceiling is 55°C ambient at the board surface — if your cabinet runs hotter than that, the issue is cabinet cooling, not the board. We’ve seen units pulled from 15-year-old installations in Southeast Asian cement plants that still pass functional test after cleaning. That’s what industrial-grade component selection looks like.
Every unit we ship undergoes a pre-dispatch functional check: power-on self-test, communication interface verification, and visual inspection for capacitor bulge, trace damage, and connector pin condition. Units that don’t pass don’t ship.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL, FedEx, and UPS Express service to major industrial hubs worldwide.
- Order confirmed before 15:00 CST: Same-day pick, pack, and handoff to courier.
- DHL Express Worldwide: 1–3 business days to Europe, Middle East, Southeast Asia. 2–4 days to the Americas.
- FedEx International Priority: Available as an alternative for destinations with stronger FedEx coverage (US, Canada, Mexico).
- Export documentation: Commercial invoice, packing list, and certificate of origin prepared same day. HS code 8537.10 declared for customs clearance. We handle export licensing for standard industrial automation components — no delays on your end.
- Tracking: AWB number sent via email and WhatsApp within 2 hours of courier pickup.
- Packaging: Anti-static ESD bag, foam-lined double-wall carton, fragile labeling. The board arrives in the same condition it left our warehouse.
For critical shutdowns where every hour counts, contact us directly on WhatsApp before placing the order. We can confirm stock, pull the unit for visual inspection, and send you photos before you commit. That’s the level of service your downtime situation demands.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.