Bently Nevada 330130-080-01-00 Extension Cable
Request verified availability, condition, replacement risk review, packing options and courier lead time for 330130-080-01-00.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330130-080-01-00
- Product Type
- Proximity Transducer Extension Cable
- Series / Family
- 3301
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Operating Temp.
- −40 °C to +85 °C
- Compliance
- API 670, CE, CSA, FM
330130-080-01-00 In Stock Now — Every Hour of Downtime Costs You More Than This Cable
Your turbine train is down. The DCS is throwing gap voltage alarms. Maintenance is standing by. You’ve traced the fault to the extension cable — and now you need a verified OEM replacement in your hands, not in three weeks. The Bently Nevada 330130-080-01-00 is on our shelf in Xiamen. We ship DHL Express same day on confirmed orders. That’s the only thing that matters right now.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | 330130-080-01-00 | ✔ Ready to Ship |
| Brand | Bently Nevada | 100% Original OEM |
| Series | 3300 XL Proximity Transducer System | — |
| Cable Length | 8.0 m (26.2 ft) | — |
| Cable Function | Probe-to-Proximitor® Extension | — |
| Connector — Probe End | 3-pin MIL-spec coaxial, male | — |
| Connector — Proximitor End | 3-pin MIL-spec coaxial, female | — |
| Characteristic Impedance | 50 Ω nominal | — |
| Operating Temperature | −40 °C to +85 °C | — |
| Jacket / Armor | Stainless steel braid over PTFE inner | — |
| Probe Compatibility | 3300 XL 8 mm, 11 mm, 14 mm, 25 mm systems | — |
| Compliance | API 670, CE, CSA, FM | — |
| Weight | ~500 g | — |
| Country of Origin | USA | — |
| Dispatch Lead Time | Same day / next business day | ✔ Ready to Ship |
Troubleshooting & Replacement Tips
Fault Pattern Recognition
Before you pull the cable, confirm the fault is actually in the extension and not the probe or Proximitor® sensor. The fastest field check: measure DC gap voltage at the Proximitor® output terminal. Nominal gap for most 3300 XL installations is −10.0 VDC ± 0.5 V at mid-gap. If you’re reading open-circuit (near 0 V) or a hard rail (−24 V), disconnect the extension cable at both ends and measure continuity on the center conductor and shield separately. A broken center conductor gives you the open-circuit reading; a shorted shield-to-center gives you the rail. Either way, the cable is the culprit.
Common fault codes triggered by a failed 330130-080-01-00:
- 3500 Monitor — Alert/Danger on Radial Vibration channel: Gap voltage out of range, often caused by intermittent open in the extension cable under vibration. Wiggle the cable at both connectors while watching the gap voltage on the monitor front panel — a flickering reading confirms a connector or conductor fault.
- 3300 XL Monitor — Not OK LED: The Proximitor® Not OK relay trips when gap voltage falls outside the configured OK range. A severed or corroded extension cable is the most common non-probe cause.
- DCS Analog Input — Frozen or pegged reading: If the vibration channel reads exactly 4 mA or 20 mA with no variation, the signal chain is broken. Isolate at the Proximitor® output before assuming a monitor card fault.
Step-by-Step Replacement Procedure
- Isolate the measurement channel. Bypass or inhibit the associated alarm/trip in the safety system before disconnecting anything. Confirm with the control room.
- Verify the replacement cable length code. The -080- in 330130-080-01-00 denotes 8.0 m. The Proximitor® sensor is factory-calibrated for this exact length. Installing a 5.0 m or 9.0 m cable without recalibration will shift the scale factor and produce incorrect vibration readings. Do not substitute lengths.
- Inspect connectors before installation. Check the MIL-spec coaxial connectors on both the new cable and the mating Proximitor® / probe connectors for bent pins, corrosion, or contamination. Clean with isopropyl alcohol and a lint-free swab. A single contaminated pin will degrade signal integrity across the full measurement range.
- Route and secure the cable. Maintain a minimum bend radius of 50 mm. Avoid routing parallel to high-voltage power cables — maintain at least 150 mm separation or use shielded conduit. Secure with stainless steel cable ties at intervals no greater than 500 mm in high-vibration zones.
- Verify gap voltage after connection. With the machine at rest, confirm gap voltage is within the OK range defined in your Proximitor® datasheet (typically −10 VDC ± 10% for 8 mm probes). If the reading is outside range, check probe tip-to-shaft gap before assuming a cable fault in the new unit.
- Remove inhibit and confirm channel health. Restore the alarm/trip inhibit, verify the monitor front panel shows OK status, and log the replacement in your maintenance management system with the new cable serial number.
Configuration Notes
- No firmware update or DIP switch change is required on the 3300 XL Proximitor® when replacing a like-for-like cable of the same length.
- If you are migrating from a 3300 NSv system, verify Proximitor® model compatibility — the 330130 series is not interchangeable with NSv-specific cabling without engineering review.
- ATEX/IECEx hazardous-area installations: confirm the replacement cable carries the same Ex certification suffix as the original. Contact us with your area classification before ordering.
Reliability in Harsh Conditions
The 330130-080-01-00 is built for environments that destroy ordinary instrumentation cable. The stainless steel armor braid is not decorative — it is the primary mechanical defense against abrasion from adjacent piping, accidental impact during maintenance, and the constant micro-fatigue induced by machinery vibration. In compressor trains running at 10,000+ RPM, the cable sees continuous vibration energy transmitted through the probe mounting boss. Lesser cables develop micro-fractures in the conductor stranding within months. The 330130 series uses a multi-strand silver-plated copper center conductor specifically to resist this fatigue mechanism.
The PTFE dielectric is equally deliberate. Polytetrafluoroethylene maintains its dielectric constant within ±1% across the full −40 °C to +85 °C operating range. In outdoor installations on gas turbines in desert climates or offshore platforms, where ambient temperatures swing 60 °C between night and day, this stability is what keeps your gap voltage reading accurate without seasonal recalibration.
Moisture ingress is the silent killer of proximity transducer systems. The MIL-spec coaxial connectors on the 330130-080-01-00 incorporate O-ring seals rated to IP67. In steam turbine environments where condensate is a constant presence, or in tropical climates with 95% relative humidity, this sealing is the difference between a system that runs for years and one that fails during the next rainstorm. We inspect every connector seal before shipment — if the O-ring shows any compression set or cracking, the unit does not leave our warehouse.
Global Express Logistics
Our dispatch hub is in Xiamen, China — one of the most connected export ports in Asia, with direct DHL Express and FedEx International Priority lanes to every major industrial hub globally. Here is exactly what happens after you confirm your order:
- Order confirmed before 14:00 CST: Same-day pick, pack, and handover to DHL/FedEx. Tracking number issued within 2 hours of dispatch.
- Export documentation: Commercial invoice, packing list, and Certificate of Conformance generated automatically. For orders requiring dual-use or end-user declarations, our logistics team handles the paperwork.
- Transit times (DHL Express from Xiamen): Southeast Asia 1–2 days | Middle East 2–3 days | Europe 3–4 days | North America 3–5 days | South America / Africa 4–6 days. Business-day estimates under normal customs clearance conditions.
- Customs clearance: We pre-classify all shipments with the correct HS code for instrumentation cable (8544.42). Accurate classification prevents customs holds. If your country requires an import license for industrial instrumentation, notify us at order — we have handled this for customers in India, Brazil, Saudi Arabia, and Nigeria.
- Emergency freight: For critical shutdowns where standard express is not fast enough, we can arrange charter courier or hand-carry service. Contact us directly on WhatsApp for same-day quotes.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.