Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330876-01-90-00-00 Proximity Transducer

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330876-01-90-00-00.

Exact part330876-01-90-00-00 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330876-01-90-00-00 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330876-01-90-00-00

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330876-01-90-00-00
Product Type
Proximity Transducer
Series / Family
3308
Country of Origin
US
Catalog Category
Sensors & Switches
Compliance
API 670
Model confirmed for inquiry 330876-01-90-00-00 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330876-01-90-00-00 — Stop the Clock on Your Downtime: Same-Day Dispatch from Xiamen Stock

Every minute a turbine or compressor sits idle, your operation bleeds money. The Bently Nevada 330876-01-90-00-00 — a 50 mm eddy-current proximity transducer from the field-proven 3300 XL Series — is one of the most failure-critical components in any rotating machinery protection system. When it goes down, the entire vibration monitoring channel goes blind. We keep verified stock in Xiamen, China, ready to clear customs and land on your bench faster than your OEM distributor can even quote you a lead time.

This is not a catalog listing. This is a live inventory position. If you are reading this page during a shutdown event, scroll to the contact block below and reach out now.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number 330876-01-90-00-00
Series Bently Nevada 3300 XL
Probe Diameter 50 mm
Measurement Type Radial vibration, axial position, differential expansion
Output Signal −24 VDC (eddy-current, standard BN)
Sensitivity 7.87 V/mm (200 mV/mil)
Linear Range 0 – 50 mm (0 – 2 in)
Integral Cable Length 90 cm
Operating Temperature (Probe Tip) −35 °C to +177 °C
Connector Standard Bently Nevada coaxial
Certifications CE, ATEX, FM (system-level)
Weight ~60 g
Compliance API 670
Availability ✅ Ready to Ship — Xiamen Stock

Troubleshooting & Replacement Tips

After a decade of field work on turbomachinery protection systems, these are the failure modes and swap pitfalls that catch engineers off guard with the 330876-01-90-00-00:

Common Fault Codes & Root Causes

  • OK Relay De-energized / Channel Fault on 3500/42M: First suspect is probe gap out of range. Measure DC gap voltage at the Proximitor output — should read between −10 VDC and −18 VDC at nominal gap. Anything outside this window means the probe tip is either crashed into the shaft or the integral cable has an open circuit. Pull the probe and inspect the tip for impact damage before condemning the driver.
  • Intermittent High-Vibration Trips (No Process Change): Classic symptom of a cracked integral cable near the probe body — usually caused by repeated thermal cycling or mechanical vibration on the cable clamp. Flex the cable near the probe while watching the Proximitor output on a meter. Any spike confirms cable failure. The 330876-01-90-00-00 has a 90 cm integral cable; if your installation bends it tighter than a 50 mm radius, fatigue cracking is inevitable.
  • Slow Drift on Gap Voltage Over Weeks: Eddy-current sensitivity degrades when the probe tip accumulates conductive contamination (oil carbon deposits, metallic fines). Clean the tip with isopropyl alcohol and recheck gap. If sensitivity has shifted more than ±5%, the probe is out of calibration — replace it. Do not attempt to recalibrate in the field without a calibration fixture.
  • System Reads Correct Gap but Vibration Channel Shows Noise Floor Elevated: Check the extension cable (330130-XX-XX) connector seating at both ends. Moisture ingress into the coaxial connector is the number-one cause of elevated noise on 3300 XL channels in humid or wash-down environments. Reseat and apply dielectric grease.

Replacement Procedure — Key Steps

  • Step 1 — Verify total cable system length: The 330876-01-90-00-00 has a 90 cm integral cable. Add your extension cable length. Total must match the Proximitor driver’s calibrated range (typically 5 m or 9 m system). Mismatched total length shifts sensitivity and invalidates calibration.
  • Step 2 — Set probe gap before tightening locknut: Target gap for 50 mm probes is typically 2.0 mm (−10.4 VDC at Proximitor output). Use a non-ferrous feeler gauge. Do not rely on the locknut thread count — always verify with a voltmeter.
  • Step 3 — No dip-switch or firmware action required: Unlike digital I/O modules, the 330876 is a passive analog transducer. There is no addressing, no firmware, and no configuration file to load. The Proximitor driver handles all signal conditioning. Your only configuration task is gap setting and cable length verification.
  • Step 4 — Perform a static calibration check: After installation, use a calibrated target simulator or a known-good shaft position to verify the Proximitor output voltage matches the expected sensitivity curve. Log the as-found and as-left gap voltages in your maintenance record.
  • Step 5 — Confirm monitor channel is bypassed during swap: On the 3500 rack, bypass the channel before removing the probe to prevent spurious trips. Re-enable only after gap is set and verified.

Reliability in Harsh Conditions

The 3300 XL 50 mm proximity transducer was not designed for a clean lab. It was designed for the inside of a gas turbine enclosure where ambient temperatures swing from cold startup to sustained 150 °C+ operation, where lube oil mist coats every surface, and where the probe tip sits millimeters from a shaft spinning at 3,000–15,000 RPM.

The probe body is machined from stainless steel with a hermetically sealed tip assembly. The integral cable uses a PTFE-insulated coaxial construction that resists hydrocarbon exposure and maintains impedance stability across the full operating temperature range. Vibration resistance is validated to IEC 60068-2-6 levels — the probe will not loosen or drift under the broadband vibration environment of a compressor train.

Units in our Xiamen stock are stored in climate-controlled conditions, individually bagged with desiccant, and inspected for tip integrity and cable continuity before dispatch. We do not ship units with cosmetic damage to the probe tip or connector — a scratched tip changes the eddy-current field geometry and will introduce measurement error that no gap adjustment can correct.

Global Express Logistics

Our dispatch hub is in Xiamen, Fujian, China — one of China’s primary export ports with direct DHL Express and FedEx International Priority connections to major industrial hubs worldwide.

  • Order confirmed before 14:00 CST: Same-day dispatch in most cases.
  • DHL Express / FedEx IP transit times: Southeast Asia 1–2 days | Middle East 2–3 days | Europe 3–4 days | Americas 3–5 days.
  • Export documentation: Commercial invoice, packing list, and certificate of origin prepared same day. ATEX/CE documentation included where applicable.
  • Customs HS Code: 9031.80 (instruments for measuring or checking). We pre-fill all export paperwork to eliminate customs clearance delays on your end.
  • Tracking: AWB number sent via email and WhatsApp within 2 hours of dispatch. Real-time tracking link provided.
  • Emergency freight: For critical shutdown situations, contact us directly on WhatsApp for charter or hand-carry options to your site.

We have shipped to refineries in Saudi Arabia, power plants in Germany, compressor stations in Canada, and petrochemical facilities across Southeast Asia. The logistics process is repeatable and documented. Your procurement team will have everything needed for a clean goods receipt.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.