Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330907-05-30-10-02-00 Proximity Probe

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330907-05-30-10-02-00.

Exact part330907-05-30-10-02-00 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330907-05-30-10-02-00 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330907-05-30-10-02-00

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330907-05-30-10-02-00
Product Type
Proximity Probe
Series / Family
3309
Country of Origin
US
Catalog Category
Sensors & Switches
Operating Temp.
−35°C to +177°C
Model confirmed for inquiry 330907-05-30-10-02-00 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330907-05-30-10-02-00 — Stop the Clock on Your Downtime. Ship Today.

Every hour a turbine, compressor, or pump runs blind — without a functioning proximity probe — is money bleeding out of your operation. A failed Bently Nevada 330907-05-30-10-02-00 doesn’t just trip an alarm; it takes your entire API 670 machinery protection loop offline. Shaft radial vibration goes unmonitored. Bearing displacement data disappears. Your DCS is flying without instruments. We stock this part in Xiamen and ship globally via DHL/FedEx Express — because waiting three weeks for a factory lead time is not an option when your critical rotating asset is down.

The 330907-05-30-10-02-00 is a reverse-mount eddy-current proximity probe from Bently Nevada’s 3300 XL platform — the global standard for turbomachinery protection in power generation, oil & gas, and petrochemical facilities. Its reverse-mount geometry solves a specific mechanical problem: bearing housings where the probe must be inserted from the non-drive end, threading backward through a confined bore. No other standard 5mm probe in the 3300 XL family handles this geometry. If this part is wrong, nothing else fits.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number 330907-05-30-10-02-00
Series Bently Nevada 3300 XL
Probe Type Eddy-Current, Reverse Mount
Tip Diameter 5 mm
Integral Cable Length 30 cm
Linear Measurement Range 0.25 mm – 2.25 mm
Sensitivity 7.87 V/mm (200 mV/mil)
Supply Voltage −24 VDC nominal
Operating Temperature −35°C to +177°C
Target Material AISI 4140 steel or equivalent
Compatible Proximitor 3300 XL 8mm / 3300 XL 11mm
Compatible Extension Cable 330130 / 330180 series
Approvals CE, ATEX (zone per datasheet)
Weight 290 g (with cable)
Stock Status ✔ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Most common failure modes for the 330907-05-30-10-02-00:

1. Open-circuit probe tip (physical damage or cable fatigue)
Symptom: Proximitor output rail-high (+VDC) or rail-low. 3500 monitor throws a “Not OK” channel fault. Check: Disconnect probe at the junction box. Measure DC resistance across probe pins — should read 8–12 Ω. Open circuit = probe dead. Short circuit = cable crush or connector corrosion. Action: Replace probe + re-run loop calibration.

2. Sensitivity drift — gap voltage out of spec
Symptom: Vibration readings are stable but absolute gap voltage has shifted outside the 10–18 VDC window at nominal air gap. Root cause: Probe tip contamination (oil varnish, metallic debris), or target surface damage. Action: Clean target area with IPA. Re-gap probe to 1.0 mm nominal. Verify output at proximitor terminal. If sensitivity is still off by >5%, replace probe and recalibrate the full loop.

3. Intermittent signal — connector corrosion at junction box
Symptom: Sporadic “Not OK” trips, especially after rain or steam purge. Vibration spectrum shows noise floor spikes. Action: Inspect MIL-spec connector at junction box. Clean with contact cleaner. Apply dielectric grease. If connector body is cracked, replace the extension cable assembly (330130 series) before condemning the probe itself.

Replacement procedure — field checklist:

  • De-energize the proximitor supply (−24 VDC) before disconnecting. Do not hot-swap — transient voltage spikes can damage the monitor input card.
  • Record the existing gap voltage before removal. This is your baseline for re-gapping the new probe.
  • Reverse-mount probes thread in from the back of the bearing housing. Use the correct probe wrench — do not use pipe grips on the probe body. Torque to 2.5 N·m maximum.
  • After installation, set air gap to 1.0 mm (±0.1 mm) using a feeler gauge or dial indicator. Verify proximitor output reads 10.0–12.0 VDC at this gap.
  • Perform a full loop calibration per Bently Nevada procedure TDI-8476. Document the calibration record — required for API 670 compliance audit.
  • Confirm the 3500 monitor channel returns to “OK” status and vibration baseline matches pre-failure trend data.
  • If the replacement probe is from a different manufacturing batch, re-verify the sensitivity curve at three gap points (0.5 mm, 1.0 mm, 1.5 mm) before returning the machine to service.

Matched system reminder: The 330907-05-30-10-02-00 must be used as part of a calibrated probe/extension cable/proximitor set. Mixing components from different calibration batches introduces measurement error. If you are replacing only the probe, retain the original extension cable and proximitor — and still perform a full loop cal.

Reliability in Harsh Conditions

The 3300 XL probe platform was not designed for a clean lab. It was designed for the inside of a gas turbine enclosure at 160°C, a centrifugal compressor train in a coastal LNG facility, and a steam turbine bearing pedestal running 24/7 for 18 months between outages. The 330907-05-30-10-02-00 reflects that design intent at every level.

The probe body is machined from 316 stainless steel with a hermetically sealed tip assembly. The integral cable uses a PTFE-jacketed coaxial construction that resists oil, steam, and hydrocarbon condensate. The reverse-mount tip geometry is protected by the bearing housing bore itself during operation — it is physically shielded from direct impingement by lube oil jets or debris. Operating temperature ceiling of 177°C covers the vast majority of steam turbine bearing environments without derating.

Vibration immunity is inherent to the eddy-current measurement principle — there are no moving parts, no piezoelectric elements to fatigue, no resonant frequencies to worry about in the probe itself. The probe has been validated to IEC 60068-2-6 vibration profiles and IEC 60068-2-27 shock profiles. In practice, units installed on large reciprocating compressors — where structure-borne vibration levels routinely exceed 5g — have demonstrated service lives exceeding 10 years without recalibration drift outside tolerance.

Humidity and condensation are handled by the hermetic seal at the probe tip and the MIL-C-5015 connector system at the junction box. For installations in tropical or coastal environments, we recommend applying a thin bead of RTV silicone around the junction box connector backshell as an additional moisture barrier — a 10-minute field modification that has prevented dozens of corrosion-related failures in our customers’ experience.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province — one of China’s primary industrial export hubs with direct access to DHL, FedEx, and UPS international express networks. For urgent replacement orders, this is what the timeline looks like:

  • Order confirmed before 14:00 CST: Same-day dispatch from Xiamen warehouse.
  • DHL Express Worldwide: 1–3 business days to most of Europe, Middle East, and Southeast Asia. 2–4 business days to North America and Australia.
  • FedEx International Priority: 1–2 business days to the US, Canada, and major EU hubs.
  • Export documentation: Commercial invoice, packing list, and certificate of origin issued same day. ATEX/CE documentation available on request for customs clearance in regulated markets.
  • Tracking: AWB number provided within 2 hours of dispatch. Real-time tracking link sent via email and WhatsApp.

We have shipped to refineries in Saudi Arabia, power plants in Germany, compressor stations in Canada, and LNG terminals in Australia — all on emergency timelines. Customs clearance in most destinations is handled by DHL/FedEx brokerage. For destinations with complex import requirements (India, Brazil, Indonesia), contact us before ordering and we will advise on documentation requirements to avoid clearance delays.

Packaging: Each probe is shipped in its original OEM packaging where available, or in anti-static foam-lined rigid cartons with moisture-barrier inner bags. The probe tip is protected by a machined plastic cap during transit. We do not ship proximity probes in bubble wrap envelopes — the connector and cable assembly require rigid protection.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.