Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens A5E02630230 Communication Option Board – SINAMICS Series

Request verified availability, condition, replacement risk review, packing options and courier lead time for A5E02630230.

Exact partA5E02630230 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part NumberA5E02630230 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ A5E02630230

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
A5E02630230
Product Type
Communication Option Board
Series / Family
SINAMICS
Country of Origin
DE
Catalog Category
Motor Drives
Operating Temp.
0 °C to +55 °C
Model confirmed for inquiry A5E02630230 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens A5E02630230 — PROFIBUS DP Option Board: Fieldbus Node Architecture for SINAMICS Variable-Speed Drives

The Siemens A5E02630230 is a factory-original PROFIBUS DP communication option board designed for installation into the option slot of SINAMICS S120, G130, and G150 drive platforms. Its primary function within a drive-based control architecture is to establish a deterministic, protocol-compliant data channel between the drive’s internal control processor and a PROFIBUS DP master — typically a SIMATIC S7-300, S7-400, or S7-1500 PLC, or any IEC 61158-conformant Class 1 master from third-party vendors.

In the absence of a dedicated communication option board, a SINAMICS drive operates in isolated local control mode, relying on analog setpoint inputs or USS protocol over RS-485 for external command. The A5E02630230 replaces this architecture entirely: once seated in the option slot and recognized by the Control Unit firmware, the drive registers as a PROFIBUS DP slave node with a configurable station address (1–125), participates in the master’s cyclic polling schedule, and exchanges process data — control word, speed setpoint, status word, actual speed value — at every bus cycle without CPU intervention on the drive side.

The module’s onboard PROFIBUS ASIC handles the complete DP protocol stack in hardware, including token-ring arbitration participation, telegram framing, CRC generation and verification, and DP-V1 acyclic service handling. This hardware-level protocol execution means the drive’s main Control Unit processor is not burdened with fieldbus stack overhead, preserving its full computational capacity for closed-loop speed and torque regulation, safety function monitoring, and DRIVE-CLiQ topology management.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Siemens Part Number A5E02630230
Module Category PROFIBUS DP Communication Option Board
Compatible Drive Platforms SINAMICS S120, G130, G150
Fieldbus Protocol PROFIBUS DP V0 / DP-V1 (Class 1 & Class 2)
Drive Profile PROFIdrive V4.1
Maximum Baud Rate 12 Mbit/s (auto-detected)
Physical Interface 9-pin Sub-D female (RS-485), galvanically isolated
Isolation Voltage (RS-485) ≥ 500 V DC
Station Address Range 1 – 125 (DIP-switch or parameter-configurable)
Cyclic Telegram Types PPO Type 1 / 2 / 3 / 4 / 5; free telegram (Telegram 999)
Acyclic Services DP-V1 Read/Write (Class 1 & Class 2 master access)
GSD File Reference SI0C0B2E.GSD (Siemens-supplied)
Supply Voltage Backplane-powered via option slot (3.3 V / 5 V internal rails)
Power Dissipation ≤ 1.5 W
Operating Temperature 0 °C to +55 °C
Storage Temperature −40 °C to +70 °C
Relative Humidity 5 % to 95 %, non-condensing (IEC 60068-2-78)
EMC Standard EN 61800-3, Category C2 / C3
Degree of Protection IP20 (module body)
Approximate Weight 300 g
Country of Origin Germany
Warranty Period 12 months from confirmed dispatch date

Hardware Logical Analysis

The RS-485 physical layer of the A5E02630230 incorporates a galvanic isolation barrier with a rated isolation voltage of ≥ 500 V DC, implemented via high-speed optocouplers on both the transmit and receive signal paths. In multi-cabinet drive installations — where the PROFIBUS trunk cable may span separate electrical enclosures fed from different transformer secondaries — ground potential differences of tens of volts between cabinet PE rails are not uncommon. Without galvanic isolation, these potential differences drive common-mode currents through the RS-485 cable shield and signal conductors, producing differential noise that corrupts telegram data at the receiver. The A5E02630230’s isolation barrier breaks this ground loop path entirely, maintaining signal integrity independent of inter-cabinet ground topology.

The PROFIBUS ASIC embedded in the module implements the token-passing MAC (Medium Access Control) layer in dedicated hardware logic rather than firmware. Token-ring participation — including token claim, token pass, and gap update procedures — executes within the ASIC’s state machine at nanosecond-scale timing resolution. This is architecturally significant: in a PROFIBUS network with a tight configured slot time (T_slot), any software-based token handler would introduce variable interrupt latency that could cause the module to miss its transmission window, triggering a retry cycle and effectively doubling the bus cycle time for that node. The hardware state machine eliminates this latency source, guaranteeing that the module responds within T_slot under all operating conditions, including during concurrent acyclic DP-V1 transactions.

The PCB ground plane of the option board is bonded to the drive’s PE (protective earth) rail through the option slot connector’s ground pins, establishing a low-impedance high-frequency return path for EMI currents. The Sub-D connector shell is independently bonded to the same PE rail, ensuring that the PROFIBUS cable shield — when terminated at the connector shell per EN 50170 installation guidelines — forms a continuous shielded enclosure from the cable entry point through to the PCB ground plane. This three-node shielding topology suppresses capacitively coupled high-frequency interference from adjacent power electronics (IGBT switching transients at 4–16 kHz carrier frequency) from entering the RS-485 differential pair, maintaining eye diagram margin at 12 Mbit/s over cable segments up to 100 m.

Acyclic DP-V1 parameter access uses a dedicated internal message buffer pool that is architecturally isolated from the cyclic process data FIFO. A DP-V1 Class 2 read transaction initiated by a STARTER engineering tool or SCADA OPC server — which may involve multi-segment data blocks requiring several bus cycles to complete — does not compete for buffer space with the cyclic setpoint telegram. The drive’s speed controller receives a fresh setpoint value at every bus cycle regardless of the state of any concurrent acyclic transaction, preserving closed-loop control determinism during online parameter access operations.

System Integration Benefits

  • Cycle-synchronous setpoint injection: PROFIBUS DP cyclic telegrams deliver speed reference and torque limit values to the drive interpolator at fixed intervals (1 ms to 8 ms depending on master configuration), enabling coordinated multi-axis positioning without inter-drive setpoint skew accumulation.
  • Standardized PROFIdrive state machine: The module implements the PROFIdrive V4.1 control word / status word state machine, allowing the PLC to use standard IEC 61131-3 drive function blocks (e.g., SIMATIC FB284, MC_Power) without drive-model-specific code branches, reducing PLC program complexity and commissioning time.
  • Full parameter transparency via DP-V1: The DP-V1 Class 2 interface exposes the complete SINAMICS parameter set (all r- and p-parameters) to any connected master with Class 2 capability, enabling online parameter reads, fault buffer extraction, and drive configuration changes without a dedicated point-to-point engineering connection.
  • Sub-cycle fault propagation: Drive fault codes and alarm bits are mapped into the PROFIBUS status word and transmitted to the PLC at every bus cycle. The PLC fault handler receives drive fault information within one scan cycle of fault occurrence — not at the next polling interval — enabling faster protective reaction in safety-relevant applications.
  • Concurrent multi-master access: DP-V1 Class 2 services allow a secondary master (engineering PC, SCADA server) to access drive parameters simultaneously with the primary PLC master’s cyclic control traffic, without requiring network reconfiguration or interruption of the production process.
  • GSD-based configuration portability: The SI0C0B2E.GSD file encodes all supported telegram configurations, I/O data lengths, and module identifiers in a vendor-neutral format, enabling configuration in TIA Portal, STEP 7 Classic, and third-party PROFIBUS configuration tools from Rockwell Automation, Schneider Electric, and ABB without manual data record entry.
  • Hardware watchdog with configurable drive response: The module’s internal watchdog monitors PROFIBUS token activity and, upon detecting bus interruption beyond the configured watchdog timeout, triggers a parameterizable drive response — coast stop (OFF2), controlled ramp-down (OFF3), or hold-last-setpoint — preventing uncontrolled drive behavior during network cable faults or master CPU failures.
  • Wiring infrastructure reduction: A single PROFIBUS trunk cable with T-connectors replaces individual shielded analog setpoint cables (±10 V or 4–20 mA) and discrete digital I/O wiring to each drive node, reducing panel wiring labor hours, cable tray fill factor, and the probability of wiring errors in installations with 10 or more drive axes.

Quality Assurance & Global Logistics

Each A5E02630230 unit shipped from our Xiamen, China operations center is a factory-original Siemens AG component sourced through documented industrial procurement channels. Every unit retains the original Siemens part label bearing the full part number, manufacturing batch code, production date, and CE / UL marking where applicable. Our pre-dispatch inspection protocol covers label authenticity verification, Sub-D connector pin geometry check (pin straightness, plating condition), PCB surface examination for physical damage or contamination, and ESD packaging seal integrity confirmation.

Units are packed individually in IEC 61340-5-1 compliant anti-static shielding bags, placed within foam-insert cartons sized to prevent movement during transit. Export documentation — commercial invoice, packing list, certificate of origin, and where required, ECCN classification statement — is prepared for each shipment. The applicable HS Code for customs classification is 8537.10 in most jurisdictions; buyers requiring jurisdiction-specific classification confirmation should contact us prior to order placement.

Standard logistics options from Xiamen include DHL Express (estimated 3–5 business days to Europe and North America), FedEx International Priority (4–6 business days), and UPS Worldwide Expedited. Sea freight LCL consolidation is available for bulk orders of 10 or more units. All shipments include end-to-end tracking. The 12-month warranty covers manufacturing defects and covers replacement dispatch within 5 business days of confirmed receipt of the defective unit at our Xiamen facility.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.