Siemens 6AG1341-1CH02-7AE0 Serial Communication Processor
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6AG1341-1CH02-7AE0.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 6AG1341-1CH02-7AE0
- Product Type
- Serial Communication Processor
- Series / Family
- SIMATIC S7-300
- Country of Origin
- DE
- Catalog Category
- Communication
- Operating Temp.
- −25 °C to +70 °C
- Humidity
- 5–95% RH
Siemens 6AG1341-1CH02-7AE0 SIPLUS CP 341 — Stop the Clock on Your Downtime
Every minute your S7-300 line sits idle, you’re bleeding money. A failed CP 341 communication processor doesn’t just kill serial comms — it takes your entire data exchange loop with it: drives go deaf, analyzers stop reporting, SCADA loses its field nodes. We stock the 6AG1341-1CH02-7AE0 precisely for this moment. Verified original Siemens SIPLUS hardware, pre-inspected, labeled, and ready to leave Xiamen within 24 hours of order confirmation. DHL Express to your dock in 2–5 business days. No waiting on distributor lead times. No compromise on authenticity.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value | Note |
|---|---|---|
| Order Number (MLFB) | 6AG1341-1CH02-7AE0 | ✅ Ready to Ship |
| Product Line | SIPLUS S7-300 CP 341 | Harsh-environment variant |
| Platform | SIMATIC S7-300 | Not compatible with S7-400 |
| Interface | RS422 / RS485 | Sub-D 15-pin female |
| Protocols | ASCII, 3964(R), RK 512 | Loadable driver architecture |
| Baud Rate Range | 300 – 76,800 baud | Software configurable |
| Bus Supply Voltage | 5 VDC (backplane) | No external PSU required |
| Current Draw (5V) | ~160 mA | Check rack power budget |
| Operating Temperature | −25 °C to +70 °C | SIPLUS extended range |
| Storage Temperature | −40 °C to +85 °C | |
| Humidity | 5–95% RH | Conformal coated PCB |
| Protection Class | IP20 | |
| Dimensions (W×H×D) | 40 × 125 × 120 mm | Standard S7-300 slot width |
| Weight | ~240 g | |
| Country of Origin | Germany | |
| Certifications | CE, UL, ATEX (check variant) | |
| Firmware Update | Via STEP 7 / TIA Portal | Field-upgradeable |
| Stock Status | ✅ In Stock — Ships within 24 hrs | Xiamen warehouse |
Troubleshooting & Replacement Tips
Symptom recognition before you pull the module: The CP 341 does not fail silently. Before condemning the hardware, check these first:
- SF LED solid red: Internal hardware fault or corrupted firmware. Try reloading the protocol driver via STEP 7 (PLC → Download → Module). If SF persists after reload, the module is defective — replace it.
- BF LED flashing: Bus fault on the backplane. Reseat the module. If BF clears, the issue was mechanical contact. If it returns, check the rack’s P-bus connector pins for corrosion — common in humid environments.
- No data exchange, both LEDs off: Check the loadable driver. An empty driver slot means the CPU rebooted and the download was lost. Re-download the protocol block from your STEP 7 project. This is the #1 field call we see after a power outage.
- Intermittent comms / CRC errors: Almost always a wiring issue on the RS485 side — missing termination resistor (120 Ω at both ends of the bus), ground loops, or cable runs exceeding 1,200 m without repeaters. Swap the module last, not first.
- OB86 triggered (rack failure): The CPU detected the CP 341 slot as unavailable. Confirm the module is seated fully — the front connector latch must click. Check for bent backplane pins.
Physical replacement procedure (field-tested sequence):
- Put the CPU in STOP mode. Do not power down the rack unless the module is showing signs of thermal damage or smoke.
- Note the slot position — the CP 341 must go back into the same slot number for the hardware configuration to match without re-downloading the entire project.
- Disconnect the RS422/RS485 sub-D cable from the front panel. Label it if there are multiple serial modules in the rack.
- Release the module locking screw (top and bottom), swing the front panel open, and slide the module out of the backplane.
- Insert the replacement 6AG1341-1CH02-7AE0 into the same slot. Seat firmly until the backplane connector is fully engaged. Tighten locking screws — finger-tight is not enough in vibration environments.
- Reconnect the RS485 cable. Verify pin assignments: Pin 3 = RxD/TxD-P (B), Pin 8 = RxD/TxD-N (A), Pin 5 = GND. Reversed A/B is the most common wiring error.
- Return CPU to RUN. The CP 341 will self-initialize from the CPU’s loaded hardware configuration. No separate module addressing or DIP switch setting is required on this model — slot-based addressing is automatic via the S7-300 backplane.
- Verify the loadable protocol driver is active: in STEP 7, go to Accessible Nodes → Module Information → Loaded Blocks. Confirm the protocol FB is present. If missing, download from your project.
- Monitor the SF and BF LEDs for 60 seconds. Green = operational. Check your SCADA for restored data points.
Firmware note: The 6AG1341-1CH02-7AE0 ships with factory firmware. If your project was configured with a specific firmware version (visible in STEP 7 HW Config → Module Properties → General), verify compatibility before going live. Firmware mismatch causes OB86 faults and communication timeouts. Firmware update is performed via STEP 7 V5.4 SP5+ or TIA Portal V13 SP1+ — no physical programmer required.
SIPLUS vs. standard CP 341 (6ES7341-1CH02-0AE0): The 6AG1341 prefix is a drop-in functional replacement for the 6ES7341 in any S7-300 rack. The hardware configuration in STEP 7 uses the same catalog entry. The only difference is the SIPLUS conformal coating and extended temperature rating — there is no software or wiring change required when substituting one for the other.
Reliability in Harsh Conditions
The SIPLUS designation is not a marketing label — it is a manufacturing specification. The 6AG1341-1CH02-7AE0 PCB undergoes conformal coating with a polyurethane or acrylic compound applied to IEC 61086 standards, protecting copper traces, solder joints, and passive components from:
- Condensation cycling: Tested to IEC 60068-2-30 (damp heat, cyclic) — the module survives repeated humidity swings from 25% to 95% RH without delamination or corrosion-induced shorts.
- Corrosive atmospheres: Validated against ISA-71.04 G3 severity (harsh) — suitable for chemical plants, wastewater facilities, and coastal installations with salt-laden air.
- Mechanical shock and vibration: Tested to IEC 60068-2-6 (sinusoidal vibration, 10–58 Hz, 0.075 mm amplitude) and IEC 60068-2-27 (shock, 15 g, 11 ms half-sine). The backplane connector and front-panel latch are rated for continuous vibration exposure — relevant for compressor rooms, rail trackside cabinets, and mobile equipment.
- Extended temperature excursions: Rated to −25 °C cold start — the module initializes correctly without pre-heating in unheated outdoor enclosures during winter shutdowns. Upper limit of +70 °C provides 10 °C of headroom above the standard CP 341 in high-ambient installations.
- EMC immunity: Compliant with EN 61000-6-2 (industrial immunity) — the RS485 interface includes internal transient suppression for surge events up to 1 kV (line-to-line) common in long cable runs through electrically noisy environments.
Units in our Xiamen stock are stored in climate-controlled conditions (18–24 °C, <60% RH) in original Siemens ESD packaging. Each module is inspected for label integrity, connector condition, and firmware version prior to dispatch. We do not ship modules with damaged front connectors or missing locking hardware.
Global Express Logistics
Our Xiamen warehouse operates Monday through Saturday. Orders confirmed before 14:00 CST ship same day. Here is the standard dispatch flow:
- Order confirmation: You receive a proforma invoice within 2 hours of inquiry. Payment via T/T, PayPal, or Shopify Payments.
- Pre-shipment inspection: The 6AG1341-1CH02-7AE0 is pulled from stock, photographed (label, connector, packaging), and the images are sent to you before dispatch — no surprises on arrival.
- Export documentation: Commercial invoice, packing list, and Certificate of Origin (China) prepared same day. HS Code: 8537.10 (programmable controllers / communication modules). We handle all export customs clearance from Xiamen.
- Carrier selection: DHL Express (default) or FedEx International Priority. Both services provide door-to-door tracking. Typical transit times: Southeast Asia 1–2 days, Europe 3–4 days, Americas 4–5 days, Middle East 3–4 days.
- Tracking notification: AWB number sent to your email within 1 hour of carrier pickup. Real-time tracking link included.
- Import duties: Shipped DAP (Delivered At Place) as standard. DDP (Delivered Duty Paid) available on request for EU and UK destinations — we handle import VAT and customs clearance on your behalf.
For critical plant shutdowns requiring next-flight-out courier, contact us directly on WhatsApp — we have handled same-day charter freight for refinery and power plant emergencies. Every hour of downtime has a cost. We move accordingly.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.