Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Yokogawa
- Primary Part Number
- F3NC01-0N
- Product Type
- Network Communication Module
- Series / Family
- STARDOM
- Manufacturer
- YOKOGAWA Electric Corporation
- Country of Origin
- JP
- Model Function
- Ethernet Network Communication Module
- Catalog Category
- Industrial Automation Spares
YOKOGAWA F3NC01-0N Ethernet Communication Module – Backbone of Distributed Control in STARDOM FCN/FCJ Architectures
In a distributed control system, the communication layer is not a peripheral concern — it is the structural backbone that determines whether field data reaches the supervisory layer with the latency and integrity that process control demands. The YOKOGAWA F3NC01-0N is the dedicated Ethernet network communication module for the STARDOM FCN and FCJ autonomous controller platform, engineered to handle deterministic data exchange between field-level controllers and SCADA or DCS supervisory systems. Its role in the control loop is not supplementary; it is the sole gateway through which the FCN/FCJ controller participates in the plant-wide communication fabric.
The STARDOM platform was designed by YOKOGAWA for applications where a full-scale DCS is operationally excessive but a simple PLC lacks the communication depth and redundancy required. The F3NC01-0N module addresses this gap directly. It provides 100BASE-TX Fast Ethernet connectivity, supports Modbus TCP and OPC DA/UA protocols natively, and integrates with YOKOGAWA’s FAST/TOOLS SCADA environment without additional middleware. For procurement engineers and MRO buyers managing aging STARDOM installations, this module is a non-substitutable line item — no alternative module occupies the same backplane slot or replicates its firmware-level integration with the FCN/FCJ CPU.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Part Number | F3NC01-0N (also referenced as F3NC01-ON) |
| Manufacturer | YOKOGAWA Electric Corporation |
| Series | STARDOM FCN / FCJ Autonomous Controller |
| Module Function | Ethernet Network Communication Module |
| Physical Interface | 100BASE-TX Fast Ethernet (RJ-45) |
| Supported Protocols | Modbus TCP/IP, OPC DA, OPC UA, YOKOGAWA proprietary (FAST/TOOLS) |
| Backplane Interface | FCN/FCJ internal bus (non-interchangeable with other YOKOGAWA series) |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 5% to 95% RH (non-condensing) |
| Power Consumption | Supplied via FCN/FCJ backplane (refer to base unit power budget) |
| Mounting | Backplane slot insertion — FCN-100, FCN-500, FCJ base units |
| Compliance | CE, UL, RoHS (refer to YOKOGAWA official datasheet for full certification scope) |
| Country of Origin | Japan |
| Warranty (siemensplc.com) | 12 months from date of shipment |
| Lead Time | In-stock units: 3–5 business days worldwide. Non-stock: 7–15 business days subject to global sourcing. Contact us for current availability before committing to a project schedule. |
Hardware Logical Analysis
The F3NC01-0N is not a generic Ethernet adapter fitted to an industrial form factor. Its hardware design reflects YOKOGAWA’s approach to deterministic field communication, where the physical layer, protocol stack, and backplane interface are co-designed to eliminate the timing variability that standard commercial networking hardware introduces into control loops.
Backplane Bus Architecture: The module communicates with the FCN/FCJ CPU via a proprietary internal bus rather than a shared memory or interrupt-driven interface. This architecture ensures that network communication tasks are handled by the F3NC01-0N’s onboard processor independently of the CPU’s scan cycle, preventing network I/O latency from propagating into the controller’s deterministic execution loop. The CPU retrieves communication data at defined synchronization points, maintaining scan cycle integrity even under high network load conditions.
EMC Design and Isolation: Industrial Ethernet environments in process plants are subject to conducted and radiated interference from variable-frequency drives, high-current switching equipment, and ground potential differences across large physical installations. The F3NC01-0N incorporates transformer-based galvanic isolation at the RJ-45 physical interface, providing common-mode rejection and protecting the module’s internal logic from transient voltages that would corrupt data frames or damage the PHY layer in non-isolated designs. The module’s PCB layout follows YOKOGAWA’s internal EMC guidelines, with ground plane segmentation between the analog front-end and digital logic sections.
Protocol Stack Implementation: Modbus TCP is implemented at the firmware level with configurable register mapping, allowing the FCN/FCJ controller’s internal data model to be exposed to third-party SCADA systems without requiring a software gateway. OPC DA/UA support enables direct integration with YOKOGAWA FAST/TOOLS and third-party HMI platforms that conform to the OPC Foundation specifications. The dual-protocol capability eliminates the need for protocol conversion hardware in mixed-vendor control architectures, reducing both capital cost and potential failure points in the communication chain.
Thermal Management: The module operates within a 0–55°C ambient range without forced cooling, relying on conductive heat transfer through the backplane mounting and passive convection within the FCN/FCJ enclosure. Component selection reflects derating practices appropriate for continuous 24/7 industrial duty, with electrolytic capacitors specified at voltage and temperature ratings that provide adequate service life margins under sustained operating conditions.
System Integration Benefits
- Deterministic Scan-Cycle Isolation: The module’s independent onboard processor handles all Ethernet stack operations autonomously, ensuring that network communication overhead does not extend the FCN/FCJ CPU scan cycle or introduce jitter into time-critical control loops.
- Zero-Middleware SCADA Connectivity: Native OPC DA/UA and Modbus TCP support allows direct connection to FAST/TOOLS, Wonderware, Ignition, and other major SCADA platforms without protocol converters or OPC bridges, reducing system complexity and eliminating an entire category of potential failure points.
- Diagnostic Transparency: The module exposes communication health metrics — frame error rates, connection status, and protocol-level diagnostics — directly to the FCN/FCJ CPU’s data model, making network faults visible within the same engineering environment used for process control logic, rather than requiring a separate network management tool.
- Plug-and-Play Backplane Replacement: The F3NC01-0N retains its IP address and protocol configuration in non-volatile memory. A module swap in a running system requires only physical replacement and power cycling — no re-parameterization of the network layer is needed, reducing mean time to repair (MTTR) in emergency maintenance scenarios.
- Multi-Master Modbus TCP Support: The module can simultaneously serve multiple Modbus TCP master connections, enabling parallel data access from historian servers, HMI stations, and remote monitoring clients without requiring sequential polling or connection arbitration at the application layer.
- Seamless FAST/TOOLS Integration: When used within a YOKOGAWA FAST/TOOLS SCADA environment, the F3NC01-0N participates in the platform’s native device discovery and tag import workflow, reducing engineering time for new installations and system expansions.
- Redundancy-Ready Architecture: The FCN/FCJ platform supports CPU redundancy configurations. The F3NC01-0N’s communication state is synchronized with the redundant CPU module, ensuring that a CPU failover event does not interrupt active Ethernet sessions or require client reconnection.
- Long-Term Platform Stability: YOKOGAWA maintains backward firmware compatibility across STARDOM FCN/FCJ generations. An F3NC01-0N installed in an existing system will operate with current FCN/FCJ firmware releases without requiring module-level firmware updates, protecting the investment in installed base systems.
Quality Assurance & Global Logistics
Every F3NC01-0N unit dispatched from siemensplc.com undergoes a structured pre-shipment verification process. Physical inspection confirms housing integrity, connector condition, and label authenticity against YOKOGAWA’s published part marking standards. Where stock condition permits, functional verification includes power-on testing and Ethernet link establishment to confirm the module’s PHY layer and onboard firmware are operational prior to dispatch.
Units are packaged in anti-static shielding bags, placed within foam-lined cartons rated for international air freight handling, and sealed with tamper-evident tape. Each shipment includes a packing list, commercial invoice, and certificate of origin prepared in compliance with Xiamen Customs export documentation requirements — ensuring smooth clearance at destination ports without delays attributable to incomplete paperwork.
Logistics from our Xiamen facility leverage direct access to Xiamen Gaoqi International Airport and Xiamen Port, two of China’s primary international freight hubs. DHL, FedEx, and UPS express services provide door-to-door delivery to most industrial destinations in North America, Europe, the Middle East, and Southeast Asia within 3–7 business days from dispatch. For volume orders, sea freight consolidation via Xiamen Port offers a cost-effective alternative with full container load (FCL) and less-than-container load (LCL) options.
Payment is accepted in USD, EUR, and HKD via T/T bank transfer, with letter of credit (L/C) arrangements available for qualified institutional buyers. All transactions are documented with formal commercial invoices suitable for corporate procurement records and import duty assessment.
12-month warranty covers functional defects attributable to the module itself under normal operating conditions. Warranty claims are processed with a target response time of 2 business days from receipt of the defective unit and supporting documentation.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, Fujian, China
© 2026 siemensplc.com. All rights reserved.