ABB 6644789A2 Controlway Daughter Card
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6644789A2.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- ABB
- Primary Part Number
- 6644789A2
- Product Type
- DCS Communication Module
- Series / Family
- INFI 90
- Manufacturer
- ABB (Asea Brown Boveri)
- Country of Origin
- SE
- Catalog Category
- Communication
- Operating Temp.
- 0°C to +60°C
- Warranty
- 12 months functional warranty
ABB 6644789A2 INFI 90 Controlway Daughter Card – Stop the Bleeding, Ship Today
Your INFI 90 node just dropped off the Controlway bus. The host processor is dark. The loop is in manual. Every minute of unplanned downtime in a process plant costs real money — and the clock is running. The ABB 6644789A2 Controlway Daughter Card is the single component standing between you and full system restoration. We stock it. We test it. We ship it today.
This daughter card is the dedicated hardware interface that plugs directly onto INFI 90 host processor boards — most commonly the IMMFP12 and IMMFP02 multi-function processors — and handles all Controlway backplane bus transactions. Without it, the host board is blind to the rest of the control network. No peer-to-peer data exchange, no supervisory visibility, no alarm propagation. The failure mode is total and immediate.
We have seen this failure pattern across power stations, pulp mills, chemical reactors, and water treatment facilities. The root causes are consistent: electrostatic discharge events during maintenance, connector fatigue from repeated board pulls, and capacitor degradation on aging INFI 90 hardware that has been running continuously for 15–25 years. When the 6644789A2 fails, there is no workaround. You need the part.
Our Xiamen warehouse holds verified stock of the ABB 6644789A2. Each unit is inspected for physical damage, tested for Controlway bus communication functionality, and packed in ESD-safe anti-static bags with desiccant before dispatch. DHL and FedEx express lanes are pre-arranged for same-day or next-morning pickup. We have shipped to power plants in Germany, paper mills in Scandinavia, and petrochemical facilities across Southeast Asia — all on emergency timelines.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | 6644789A2 |
| Manufacturer | ABB (Asea Brown Boveri) |
| Module Type | Controlway Daughter Card – Communication Interface |
| Compatible Platform | ABB INFI 90 DCS |
| Typical Host Boards | IMMFP12, IMMFP02 (Multi-Function Processor series) |
| Bus Protocol | ABB Controlway proprietary high-speed serial backplane bus |
| Form Factor | Daughter card – mounts directly on host processor PCB |
| Operating Temperature | 0°C to +60°C |
| Weight | ~40 g |
| Condition | Refurbished / Tested / New Old Stock (NOS) |
| Warranty | 12 months functional warranty |
| Stock Status | ✔ Ready to Ship – Xiamen Warehouse |
| Lead Time | Same-day dispatch for orders confirmed before 15:00 CST |
| Origin | Germany (Original ABB Manufacturing) |
Troubleshooting & Replacement Tips
Fault Signature: The most common indicator of a failed 6644789A2 is the host processor module showing a solid red fault LED with no Controlway bus activity. On INFI 90 operator consoles, affected loops will display “COMM FAIL” or “NODE OFFLINE” alarms. The host module itself may still power up and run its local diagnostics — the daughter card failure is specifically a bus communication failure, not a processor failure.
Before You Pull the Board:
- Verify the fault is isolated to a single node. If multiple nodes are offline simultaneously, suspect the Controlway cable (NTCL01/02) or termination unit (NKTU01/02) before condemning the daughter card.
- Check the Controlway bus termination resistors at both ends of the bus segment. An open termination will cause intermittent communication errors across all nodes, not just one.
- Confirm the host board’s power rails are within spec before assuming the daughter card is the failure point. A marginal +5V supply can cause Controlway communication errors that mimic a failed daughter card.
Replacement Procedure:
- Power down the host module and remove it from the INFI 90 rack following your site’s lockout/tagout procedure.
- Ground yourself with an ESD wrist strap before handling the daughter card. The 6644789A2 is sensitive to electrostatic discharge — this is the most common cause of infant mortality on replacement units.
- The daughter card connects to the host board via a multi-pin edge connector. Inspect the connector on both the card and the host board for bent pins or corrosion before seating the replacement.
- No firmware flashing is required for the daughter card itself. The host processor handles all firmware. The 6644789A2 is purely hardware — seat it, reinstall the host board, and power up.
- After power-up, allow 60–90 seconds for the host module to complete its self-test and re-establish Controlway bus synchronization. The fault LED should clear and the node should reappear on the operator console.
- If the fault persists after replacement, the issue may be on the host board’s connector interface or the Controlway bus itself — not the daughter card. Swap the host board to a known-good spare slot to isolate.
No DIP Switches or Addressing Required: Unlike some INFI 90 I/O modules that require physical address switches, the 6644789A2 daughter card carries no user-configurable settings. Node addressing is managed by the host processor firmware. Replacement is purely mechanical.
Reliability in Harsh Conditions
ABB engineered the INFI 90 platform for continuous operation in the most demanding process environments on earth — and the 6644789A2 daughter card was built to the same standard. The PCB substrate uses a high-Tg FR4 laminate rated for sustained thermal cycling without delamination. Conformal coating on production units provides a moisture barrier against the humidity levels found in coastal chemical plants and tropical paper mills.
Vibration tolerance is a design requirement, not an afterthought. INFI 90 hardware was qualified for installation in environments with continuous mechanical vibration — common in compressor stations, pump houses, and turbine halls where the control cabinet sits adjacent to rotating machinery. The daughter card’s edge connector is a friction-fit design with sufficient contact force to maintain electrical continuity under vibration loads that would cause intermittent failures in lesser hardware.
Thermal performance is equally robust. The 6644789A2 operates across a 0°C to +60°C ambient range, covering everything from unheated substations in northern climates to poorly ventilated control rooms in equatorial facilities. The low-power design of the communication interface means the daughter card itself contributes minimal heat to the host board’s thermal budget.
Every unit we ship has been stored in climate-controlled conditions and inspected for signs of environmental degradation — corrosion on connector pins, electrolytic capacitor swelling, or PCB discoloration from heat stress — before it leaves our warehouse.
Global Express Logistics
Our dispatch hub is in Xiamen, China — a major international freight gateway with direct DHL and FedEx express lanes to every major industrial region globally. Here is how the process works from the moment you confirm your order:
- Order Confirmation → Same-Day Pickup: Orders confirmed before 15:00 CST are packed, documented, and handed to the courier the same business day. Export documentation — commercial invoice, packing list, and HS code declaration — is prepared in parallel with packing.
- DHL Express / FedEx International Priority: Transit times from Xiamen: Europe 2–3 business days, North America 3–4 business days, Southeast Asia 1–2 business days, Middle East 3–4 business days, Australia 3–5 business days.
- Customs Clearance: We declare the correct HS code for industrial electronic control modules and provide all documentation required for smooth customs clearance in major import markets. For time-critical shipments, we can arrange pre-clearance documentation on request.
- Tracking: A tracking number is sent to you within 2 hours of dispatch. You can monitor the shipment in real time through the DHL or FedEx portal.
- Emergency Freight: For genuine plant-down situations, contact us directly on WhatsApp. We can arrange next-flight-out courier options for the most time-critical requirements.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.