ABB CI810A 3BSE013262R1 Communication Interface Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for CI810A 3BSE013262R1.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- ABB
- Primary Part Number
- CI810A 3BSE013262R1
- Product Type
- Communication Interface Module
- Series / Family
- AC800M
- Manufacturer
- ABB
- Country of Origin
- SE
- Catalog Category
- Communication
- Operating Temp.
- 0°C to +55°C
- Humidity
- 5% to 95% RH, non-condensing
ABB CI810A 3BSE013262R1 — Stop the Bleeding: Every Hour of DCS Downtime Costs You Real Money
Your AC800M controller just threw a communication fault. The PROFIBUS segment is dead. Production is halted. You’ve already pulled the CI810A and confirmed it’s the culprit — now you need a replacement module on-site, fast, not in six weeks. That’s exactly why this page exists.
We stock the ABB CI810A (Part No. 3BSE013262R1) in Xiamen, China, with same-day DHL/FedEx dispatch available for orders confirmed before 15:00 CST. No broker delays, no customs surprises — just a verified, original ABB module in your hands within 48–72 hours to most global destinations.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Manufacturer | ABB |
| Model | CI810A |
| Part Number | 3BSE013262R1 |
| Series | AC800M DCS |
| Module Function | PROFIBUS DP Master Communication Interface |
| Fieldbus Protocol | PROFIBUS DP (IEC 61158 / EN 50170) |
| Max Slave Devices | 125 per segment |
| Baud Rate | 9.6 kbit/s – 12 Mbit/s (auto-detect) |
| Compatible Controllers | PM861A, PM864A, PM866A (AC800M family) |
| Mounting | AC800M backplane slot |
| Power Supply | Via controller backplane (no external PSU required) |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -40°C to +70°C |
| Humidity | 5% to 95% RH, non-condensing |
| Certifications | CE, UL, RoHS |
| Country of Origin | Sweden |
| Stock Status | ✔ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
Ten years of field work teaches you that a CI810A failure rarely announces itself cleanly. Here’s what you’ll actually encounter and how to handle it:
Common Fault Indicators:
- AC800M event log shows “PROFIBUS DP: Bus fault” or “CI810A: Communication error” — check the module’s BF (Bus Fault) LED first. Solid red = segment-level issue; flashing = individual slave dropout.
- Sudden loss of all I/O on a PROFIBUS segment while the CPU itself remains healthy — classic CI810A hardware failure signature, not a cable fault.
- Module not recognized after a power cycle — backplane connector oxidation or internal firmware corruption. Swap the module before chasing the bus.
- Intermittent slave timeouts at high baud rates (6–12 Mbit/s) — can indicate a failing CI810A oscillator circuit. Drop baud rate temporarily to confirm; if stability returns, the module is degrading.
Replacement Procedure (Field-Verified):
- Step 1 — Firmware check before you pull anything. In Control Builder M, note the current CI810A firmware version (typically visible under Hardware Configuration → Module Properties). Your replacement must run the same or higher firmware. CI810A firmware is not field-upgradeable without ABB tools — order accordingly.
- Step 2 — Export the PROFIBUS configuration. In Control Builder M, export the DP master configuration (GSD files, slave addresses, I/O mapping). This takes 5 minutes and saves hours of re-commissioning.
- Step 3 — Power down the controller rack. The CI810A is NOT hot-swap capable in all firmware revisions. Unless your site has confirmed hot-swap support under your specific firmware build, shut down the PM8xx CPU cleanly via Control Builder M before pulling the module.
- Step 4 — Seat the replacement module firmly. The backplane connector requires deliberate pressure. A partially seated CI810A will power up but fail to communicate — a common cause of “new module, same fault” callbacks.
- Step 5 — Verify node address assignment. The CI810A does not use DIP switches for addressing — its PROFIBUS master address is set in software via Control Builder M. Confirm the address matches your network configuration before going live.
- Step 6 — Reload and verify. Download the application to the controller, force a PROFIBUS bus scan, and verify all slave green-lights in the diagnostic view before handing back to operations.
Firmware Compatibility Matrix (Critical): CI810A hardware revision R1 (3BSE013262R1) is compatible with AC800M controller firmware v4.x through v6.x. If your site runs firmware v6.1+, verify against ABB Technical Note 3BSE036351 before ordering. Mismatched firmware will result in the module being detected but non-functional.
Reliability in Harsh Conditions
The CI810A was not designed for a climate-controlled server room. ABB engineered this module for the realities of industrial plant environments — and it shows in the construction.
The PCB assembly uses conformal coating as standard, providing resistance to condensation, airborne contaminants, and corrosive atmospheres common in chemical and petrochemical plants. The backplane connector is gold-plated to resist oxidation in humid coastal or offshore environments — a detail that matters when your DCS cabinet is 50 meters from the sea.
Vibration tolerance meets IEC 60068-2-6 test specifications, making the CI810A suitable for installation near rotating machinery, compressors, and pump skids without additional isolation mounts. In mining and heavy industry applications where cabinet vibration is a constant, this is not a trivial specification.
Thermal management is passive — no fans, no moving parts. The module dissipates heat through the backplane and enclosure, eliminating the fan-failure failure mode that plagues lesser designs. Operating range of 0°C to +55°C covers the vast majority of industrial cabinet environments globally, including tropical climates without air conditioning.
EMC performance is validated to EN 55011 Class A and IEC 61000-4 series immunity standards. In practice, this means the CI810A maintains communication integrity in the presence of VFD switching noise, high-voltage bus bars, and welding equipment — environments where cheaper communication modules simply drop frames.
Global Express Logistics
Our Xiamen warehouse operates a same-day dispatch cut-off of 15:00 CST (UTC+8) for orders with confirmed payment. Here’s exactly what happens after you place your order:
- T+0 (Order Confirmed): Module pulled from shelf, serial number photographed, anti-static packaging applied, humidity indicator card inserted. Commercial invoice, packing list, and certificate of origin prepared.
- T+0 (Same Day): Shipment handed to DHL Express or FedEx International Priority — carrier selected based on your destination for fastest transit. Tracking number issued within 2 hours of pickup.
- T+1 to T+3: Delivery to most destinations in Southeast Asia, Japan, South Korea, Australia, Middle East, and Europe. North America typically T+2 to T+4 depending on customs clearance speed.
All shipments include full export documentation compliant with Chinese customs regulations. HS Code 8537.10 is declared for PLC/DCS communication modules. For destinations requiring import permits or end-user certificates, contact us before ordering — we handle this routinely for customers in regulated markets.
DDP (Delivered Duty Paid) terms are available for most destinations — you pay one price, we handle import duties and clearance. No surprise brokerage fees on delivery.
For genuine plant emergencies, call or WhatsApp +86 18359268345 directly. We can arrange courier pickup outside business hours for critical situations.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.