Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
ABB In Stock OK

ABB CI930F 3BDH001010R0005 PROFIBUS DP Master Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for CI930F 3BDH001010R0005.

Exact partCI930F 3BDH001010R0005 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandABB Part NumberCI930F 3BDH001010R0005 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ CI930F 3BDH001010R0005

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
ABB
Primary Part Number
CI930F 3BDH001010R0005
Product Type
PROFIBUS Communication Module
Series / Family
AC800M
Country of Origin
SE
Catalog Category
Communication
Operating Temp.
0°C to +55°C
Model confirmed for inquiry CI930F 3BDH001010R0005 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

ABB CI930F 3BDH001010R0005 — Stop the Bleed: PROFIBUS DP Master Back Online in 48 Hours

Your AC800M controller just lost its PROFIBUS DP master. Every second that fieldbus stays dark, you’re bleeding production value — drives unresponsive, remote I/O silent, operators flying blind. You don’t need a sales pitch. You need the right module, verified, boxed, and moving toward your dock today. We stock the ABB CI930F (3BDH001010R0005) in Xiamen and ship globally via DHL/FedEx express. Most destinations: 48–72 hours door to door.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value
Part Number CI930F
Order Code 3BDH001010R0005
Brand ABB
Series AC800M Controller Platform
Module Function PROFIBUS DP Class 1 Master
Protocol Standard EN 50170 / IEC 61158 Type 3
Max. Baud Rate 12 Mbit/s
Max. DP Slaves 125 per segment
Physical Interface 9-pin D-Sub (RS-485)
Backplane Connection AC800M internal module bus
Power Source Via AC800M backplane (no external PSU)
Operating Temperature 0°C to +55°C
Storage Temperature -40°C to +70°C
Relative Humidity 5%–95% RH, non-condensing
Weight ~150 g
Certifications CE, cULus
Country of Origin Germany
Stock Status ✅ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Fault Scenario 1 — PROFIBUS LED solid red or flashing red on CI930F: This almost always means the module has lost token-ring arbitration. Before condemning the card, check the termination resistors at both ends of the bus segment. A missing or failed terminator causes reflection noise that kills communication at baud rates above 1.5 Mbit/s. Swap terminators first — it costs nothing and saves you from pulling a live module unnecessarily.

Fault Scenario 2 — Slave devices show “No Communication” in Control Builder Plus after module swap: The CI930F does not store GSD (device database) files internally. After a cold replacement, Control Builder Plus must re-download the full PROFIBUS configuration to the new module. Connect your engineering station, open the project, go to the PROFIBUS master object, and execute a full download. Do not attempt a partial download — it will leave slave address tables incomplete.

Fault Scenario 3 — Module recognized by backplane but slaves remain in “Config Error” state: Verify that the firmware version on the replacement CI930F matches or exceeds the version previously installed. ABB has released multiple firmware revisions for this module. A downgrade — even by one minor revision — can cause GSD file incompatibilities with certain third-party PROFIBUS slaves. Check the firmware label on the module housing before installation. If the version is lower than your previous unit, contact ABB or your supplier for a firmware update file.

Replacement Procedure (Field-Tested Steps):

  1. Export and save the current AC800M project from Control Builder Plus before touching any hardware. This is your recovery point.
  2. Set the AC800M controller to STOP mode. Do not power down the entire rack unless your process requires it — the CI930F supports hot-swap procedures per ABB’s maintenance documentation.
  3. Disconnect the PROFIBUS D-Sub cable from the module. Label it if multiple fieldbus cables are present in the rack.
  4. Release the module locking tab and slide the CI930F out of its slot. Note the slot position — the CI930F must return to the same physical slot for the backplane address to remain consistent.
  5. Insert the replacement CI930F into the identical slot. Confirm the locking tab engages fully.
  6. Reconnect the PROFIBUS cable. Verify termination is active at this end if the CI930F is at the physical end of the bus segment.
  7. From Control Builder Plus, perform a full download to the controller. Monitor the PROFIBUS diagnostic view — all configured slaves should transition from “No Comm” to “OK” within 10–30 seconds depending on network size.
  8. Return the controller to RUN mode. Verify cyclic data exchange on critical slave devices before releasing the process.

Address & DIP Switch Notes: The CI930F does not use physical DIP switches for PROFIBUS master address assignment. The master address (default: 0) is configured entirely in software via Control Builder Plus. If you are replacing a module in a multi-master network, confirm the master address assignment in the project before download to avoid address conflicts on the bus.

Reliability in Harsh Conditions

The CI930F was not designed for a climate-controlled server room. It was built for the realities of process plant environments — where ambient temperatures swing, humidity condenses on cold mornings, and control room floors vibrate from nearby rotating machinery.

ABB engineered the AC800M platform, including the CI930F, to IEC 61131-2 environmental standards. The module’s conformal-coated PCB provides a barrier against airborne contaminants — sulfur compounds in refineries, chlorine vapors in water treatment, and conductive dust in mining applications. The backplane connector uses gold-plated contacts rated for thousands of insertion cycles, maintaining reliable electrical continuity even after repeated maintenance interventions.

Vibration resistance is validated to IEC 60068-2-6 (sinusoidal) and IEC 60068-2-64 (random), covering the frequency ranges generated by pumps, compressors, and conveyor drives mounted in the same structural bay as the control cabinet. Shock resistance per IEC 60068-2-27 ensures the module survives the mechanical events that happen in real plants — cabinet doors slamming, forklift traffic, and the occasional dropped tool.

Thermal cycling is the silent killer of electronics in process plants. The CI930F’s operating range of 0°C to +55°C accommodates the thermal load of a fully populated AC800M rack in a non-air-conditioned cabinet during summer peak. Units we supply are stored in a temperature-controlled warehouse in Xiamen and shipped in thermally insulated packaging for destinations with extreme ambient conditions.

Global Express Logistics

Our dispatch warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international express networks. Orders confirmed before 14:00 CST are processed for same-day dispatch. Here is what the logistics chain looks like from your purchase order to your receiving dock:

Day 0 (Order Confirmation): Payment confirmed, module pulled from shelf, inspected, ESD-bagged, foam-packed, and boxed. Commercial invoice, packing list, and export declaration prepared. Shipment booked with DHL Express or FedEx International Priority depending on destination routing.

Day 1 (Departure): Shipment collected by carrier from Xiamen facility. Tracking number issued and sent to buyer within 2 hours of pickup. Customs clearance initiated on the China export side — HS Code 8537.10 (programmable controllers and communication modules) is a standard, non-restricted export classification.

Day 2–3 (Transit): Typical transit times — Southeast Asia: 1–2 days. Europe: 2–3 days. Middle East: 2–3 days. North America: 3–4 days. South America and Africa: 4–5 days. These are DHL/FedEx express estimates under normal customs conditions.

Customs & Import Documentation: We provide a full commercial invoice with accurate HS code, unit value, and country of origin declaration. For customers in the EU, we can provide EUR.1 movement certificates where applicable. For customers in countries with import duty exemptions on industrial automation components, we advise on documentation requirements at the time of order.

Packaging Standard: Anti-static bag → foam insert → rigid cardboard box → outer shipping carton. Fragile and ESD-sensitive labels applied. For multi-unit orders, individual modules are separated by foam dividers. No module leaves our facility without passing a visual and connector inspection.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.