ADVANTECH ADAM-4572 Serial Gateway – ADAM-4500 Series
Request verified availability, condition, replacement risk review, packing options and courier lead time for ADAM-4572.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Advantech
- Primary Part Number
- ADAM-4572
- Product Type
- Serial Gateway
- Series / Family
- ADAM-4500 Series
- Country of Origin
- TW
- Model Function
- Ethernet-to-Serial Gateway / Device Server
- Catalog Category
- Communication
- Operating Temp.
- -10°C to +70°C
- Warranty
- 12 months from date of shipment
ADVANTECH ADAM-4572 Ethernet-to-Serial Gateway — Protocol Bridge for Industrial Control Networks
The ADAM-4572 occupies a structurally critical position in any control loop that spans both legacy serial field devices and modern Ethernet-based supervisory infrastructure. Its core function is deterministic bidirectional data relay between RS-232/RS-485/RS-422 serial endpoints and TCP/IP network hosts, operating transparently at the transport layer without modifying application-layer payloads. In Modbus-centric architectures, it additionally performs RTU-to-TCP frame encapsulation and de-encapsulation, eliminating the need for a discrete protocol converter in the signal chain. The result is a single-device solution that preserves existing serial wiring investments while enabling full Ethernet SCADA visibility — a requirement that appears consistently in brownfield retrofit specifications across power, water, and process industries.
Unlike software-only gateway solutions that introduce variable latency through OS scheduling, the ADAM-4572 executes serial-to-Ethernet conversion in firmware, delivering sub-10 ms end-to-end relay latency at standard industrial baud rates. This determinism is non-negotiable in closed-loop control applications where polling cycle overruns trigger watchdog faults or process alarms.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Model | ADAM-4572 |
| Series | ADVANTECH ADAM-4500 |
| Function | Ethernet-to-Serial Gateway / Device Server |
| Serial Interfaces | RS-232 / RS-485 / RS-422 (software selectable) |
| Serial Ports | 1 × DB9 male connector |
| Baud Rate Range | 300 bps – 115,200 bps |
| Data Bits | 5, 6, 7, 8 |
| Parity | None, Even, Odd, Space, Mark |
| Stop Bits | 1, 2 |
| Ethernet Interface | 10/100 Mbps auto-negotiation, RJ-45 |
| Supported Protocols | TCP/IP, UDP, Modbus TCP, Virtual COM (VCOM) |
| Max TCP Connections | 4 simultaneous per serial port |
| Serial Port Isolation | 1,500 VDC optical isolation |
| Power Supply Input | 10 – 30 VDC (unregulated) |
| Power Consumption | ≤ 2.5 W typical |
| Operating Temperature | -10°C to +70°C |
| Storage Temperature | -20°C to +85°C |
| Relative Humidity | 5% – 95% RH, non-condensing |
| Mounting | DIN-rail (TS-35), panel mount optional |
| Dimensions (W×H×D) | 72 × 120 × 35 mm |
| Weight | ~200 g |
| Certifications | CE, FCC Class A, RoHS 2 |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
The ADAM-4572’s internal architecture is built around a dedicated embedded processor running a real-time firmware stack — not a general-purpose Linux kernel. This design choice eliminates the boot-time latency and OS scheduling jitter that characterize Linux-based device servers, and it means the unit is operational within seconds of power application, a requirement in systems where the gateway must be available before the SCADA host completes its own startup sequence.
Optical Isolation Architecture: The 1,500 VDC serial port isolation is implemented via optocoupler barriers on both the transmit and receive data lines, as well as the RTS/CTS handshake lines where applicable. This galvanic break prevents ground potential differences — common in large industrial facilities where equipment is powered from separate distribution panels — from inducing common-mode currents that corrupt serial data frames or damage UART transceivers. In RS-485 multi-drop networks, this isolation also suppresses ground loop currents that would otherwise appear as differential noise on the bus.
RS-485 Bus Termination and Bias: The ADAM-4572 includes software-configurable internal termination resistors (120 Ω) and bias resistors for the RS-485 interface. Proper termination is mandatory at both physical ends of an RS-485 segment to prevent signal reflections at baud rates above 19,200 bps. The ability to enable termination via software configuration — rather than requiring physical jumper changes — reduces commissioning time in field installations where the unit may be the terminal node on a multi-drop segment.
EMC Design: The compact plastic enclosure incorporates internal shielding provisions, and the Ethernet port includes common-mode chokes and transient voltage suppression (TVS) diodes rated to IEC 61000-4-5 surge levels. The serial port TVS network handles ±15 kV ESD events per IEC 61000-4-2, which is the minimum acceptable threshold for field-installed equipment in environments with frequent cable connect/disconnect operations.
Modbus Gateway Logic: In Modbus gateway mode, the ADAM-4572 maintains a configurable response timeout register. When a Modbus TCP master issues a request, the gateway forwards it as an RTU frame to the serial device and holds the TCP connection open for the configured timeout period. If the serial device responds within the window, the RTU response is encapsulated into a Modbus TCP response and returned to the master. If the timeout expires, the gateway returns a Modbus exception code 0x0B (Gateway Target Device Failed to Respond), allowing the SCADA host to log a specific device fault rather than a generic communication error — a distinction that significantly reduces diagnostic time during troubleshooting.
System Integration Benefits
- Zero-modification serial software compatibility: The Virtual COM port driver presents the Ethernet-connected serial device as a standard COMx port to the host OS. Existing serial communication software, HMI drivers, and PLC programming tools operate without modification, eliminating software re-qualification costs in validated environments.
- Deterministic polling cycle support: Firmware-based serial relay with sub-10 ms latency at 9,600–115,200 bps ensures that SCADA polling cycles remain within configured scan intervals, preventing false timeout alarms in systems with tight polling budgets.
- Multi-master access to a single serial device: Up to 4 simultaneous TCP connections to one serial port allow multiple SCADA clients, historian servers, or HMI stations to poll the same field device concurrently, without requiring a serial splitter or additional hardware.
- Modbus exception code transparency: The gateway propagates Modbus exception codes from serial devices back to TCP masters intact, preserving the diagnostic granularity of the original serial protocol and enabling fault-specific alarming at the SCADA level.
- Wide DC input range for mixed power rail environments: The 10–30 VDC input accepts both 12 V and 24 V industrial power rails without a DC-DC converter, simplifying panel design in facilities where both voltage levels are present in the same cabinet.
- DIN-rail form factor for standard panel integration: TS-35 snap-mount installation requires no custom panel cutout or dedicated mounting hardware. The 72 × 120 × 35 mm footprint fits within standard 150 mm deep control enclosures alongside PLCs, I/O modules, and power supplies.
- Configurable serial parameters for legacy device compatibility: Full configurability of baud rate, data bits, parity, and stop bits — including non-standard combinations such as 7E1 or 8N2 — ensures compatibility with legacy instruments that do not conform to default serial settings.
- ADVANTECH utility software ecosystem: The Adam/Apax .NET Utility provides a graphical interface for device configuration, firmware updates, and network discovery. This eliminates the need for terminal-based configuration and reduces commissioning time for technicians unfamiliar with command-line tools.
Quality Assurance & Global Logistics
Every ADAM-4572 unit dispatched from our Xiamen, China facility is sourced through verified ADVANTECH distribution channels. Prior to shipment, each unit undergoes a structured pre-dispatch inspection covering physical label authenticity, firmware version verification, and functional power-on testing. Units are shipped in original ADVANTECH packaging with accompanying documentation.
Our 12-month warranty covers manufacturing defects and component failures under normal operating conditions. Warranty claims are processed with a target response time of 48 hours from receipt of the defective unit. Replacement units are dispatched from Xiamen stock, with DHL Express and FedEx International Priority available for time-critical replacements.
Standard international shipment lead time from confirmed order to carrier pickup is 1–3 business days for in-stock units. Export documentation including commercial invoice, packing list, and certificate of origin is prepared for all international shipments. HS Code 8517.62 applies to this product category for customs classification purposes.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.