Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 21000-16-10-00-123-03-02 Proximity Probe

Request verified availability, condition, replacement risk review, packing options and courier lead time for 21000-16-10-00-123-03-02.

Exact part21000-16-10-00-123-03-02 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number21000-16-10-00-123-03-02 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 21000-16-10-00-123-03-02

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
21000-16-10-00-123-03-02
Product Type
Proximity Probe
Series / Family
21000 Series
Country of Origin
US
Catalog Category
Sensors & Switches
Compliance
API 670, CE, RoHS
Model confirmed for inquiry 21000-16-10-00-123-03-02 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

21000-16-10-00-123-03-02 Proximity Probe – Stop the Clock on Your Downtime

Every hour a turbine or compressor train sits idle costs real money — in some petrochemical facilities, unplanned downtime runs $50,000–$200,000 per hour. When your Bently Nevada proximity probe fails and the 3500 rack trips on a “Not OK” signal, you don’t have time for a 6-week OEM lead time. We stock the 21000-16-10-00-123-03-02 in Xiamen and ship same-day or next business day via DHL Express or FedEx International Priority. Your machine gets back online. Your production manager stops calling.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number 21000-16-10-00-123-03-02 ✔ Ready to Ship
Brand Bently Nevada 100% Original OEM
Series 21000 Series
Probe Diameter 16 mm
Integral Cable Length 10 ft (3.05 m)
Linear Range 0–90 mil (0–2.286 mm)
Output Sensitivity 200 mV/mil (7.87 V/mm) Factory calibrated
Operating Temp (Probe Tip) −35°C to +177°C
Pressure Rating 500 psi (34.5 bar)
Housing Material 316 Stainless Steel
Thread 3/4–20 UNF
Connector Integral coaxial, armored cable
Compliance API 670, CE, RoHS
Compatible Drivers 3300 XL, 3500/42M Proximitor I/O
Origin USA
Dispatch Location Xiamen, China ✔ In Stock

Troubleshooting & Replacement Tips

Pulled from real field experience — here’s what actually bites engineers during a hot swap of the 21000-16-10-00-123-03-02:

1. Gap Voltage Verification Before You Torque Down
After threading the probe into the housing, set your initial gap to 1.0 mm (40 mil). With the Proximitor powered, you should read approximately −8.0 VDC at the driver output. If you’re seeing −18 VDC or worse, the probe tip is too far from the target — don’t assume the rack is faulty. Adjust gap first. The linear range is 0–2.286 mm; anything outside that and your vibration reading is garbage.

2. Extension Cable Matching — Don’t Mix and Match
The 21000-16-10-00-123-03-02 uses a 10 ft integral cable. Total system cable length (probe + extension) must match the Proximitor calibration. If you’re replacing just the probe and keeping the existing 330130 extension cable, verify the combined length matches the driver’s calibration curve. A mismatch of even 1 meter shifts sensitivity by 3–5% and will cause false high-vibration alarms.

3. 3500 Rack “Not OK” After Replacement
If the 3500/42M Proximitor I/O module shows “Not OK” immediately after probe swap, check in this order: (a) gap voltage out of linear range, (b) cable shield continuity — the armored cable ground must be terminated at one end only to avoid ground loops, (c) Proximitor power supply voltage — should be −24 VDC ±10%. A sagging power rail from a failing PSU will mimic a probe fault.

4. Thread Engagement and Locknut Torque
The 3/4–20 UNF thread requires minimum 5 full turns of engagement. Torque the locknut to 20–25 N·m. Under-torqued probes migrate axially under vibration — you’ll see a slow drift in the DC gap voltage over days, which operators often misread as bearing wear. It’s not. It’s a loose probe.

5. ATEX / Hazardous Area Installations
If your installation is Zone 1 or Zone 2, the probe itself is not the barrier — your Zener barrier or galvanic isolator is. Verify the barrier’s entity parameters (Voc, Isc, Ca, La) are compatible with the probe’s capacitance and inductance before energizing. Skipping this step is a safety violation, not just a commissioning error.

Common Fault Codes on Bently Nevada 3500 Rack:

  • OK LED off / Not OK active — Gap out of range or open circuit in probe/cable. Check gap voltage first.
  • High vibration alarm (spurious) — Ground loop on cable shield or EMI from adjacent VFD. Re-route cable away from power conductors.
  • Flat vibration signal (0 mV AC) — Probe tip contamination (oil sludge, metallic debris). Clean tip with IPA; inspect target surface for scoring.
  • Intermittent OK/Not OK cycling — Loose connector at Proximitor input or cracked cable at probe body junction. Flex the cable near the probe body while monitoring — if fault appears, replace the assembly.

Reliability in Harsh Conditions

The 21000 Series was not designed for a lab. It was designed for the inside of a bearing housing on a 60 MW steam turbine running at 3,000 RPM in a coastal refinery. The 316 stainless steel housing resists chloride-induced pitting corrosion in offshore and marine environments. The armored integral cable withstands continuous mechanical vibration — the same vibration the probe is measuring — without fatigue failure at the cable-to-body junction, which is the single most common failure point on cheaper proximity probe assemblies.

Operating temperature range of −35°C to +177°C at the probe tip covers everything from Arctic LNG facilities to hot-section gas turbine bearing housings. The 500 psi pressure rating means the probe can be installed directly in pressurized bearing housings without a separate pressure-rated housing adapter — one less potential leak point in your system.

Sensitivity stability over temperature is ±1% across the full operating range. That matters when your vibration monitoring system is making trip decisions. A probe that drifts 5% sensitivity at 150°C is not a monitoring instrument — it’s a liability. The 21000-16-10-00-123-03-02 holds calibration. That’s why API 670-compliant plants specify it.

Global Express Logistics

Stock is held at our Xiamen warehouse, positioned specifically for fast export to industrial customers across Asia-Pacific, the Middle East, Europe, and the Americas. Here’s how a typical urgent order moves:

  • Order confirmed before 14:00 CST → Same-day dispatch, DHL Express or FedEx International Priority
  • Transit to Southeast Asia → 1–2 business days (Singapore, Malaysia, Thailand, Vietnam)
  • Transit to Middle East → 2–3 business days (UAE, Saudi Arabia, Kuwait, Qatar)
  • Transit to Europe → 3–4 business days (Germany, Netherlands, UK, France)
  • Transit to Americas → 3–5 business days (USA, Canada, Brazil, Mexico)

Export documentation is prepared in parallel with packing: commercial invoice, packing list, certificate of origin, and test/inspection report ship with every unit. DDP (Delivered Duty Paid) terms available for most destinations — no customs clearance headaches on your end. For orders requiring air freight consolidation or special handling (e.g., dangerous goods co-loading), contact us directly and we’ll arrange accordingly.

Track record: over 95% of urgent orders dispatched within 4 hours of payment confirmation. We understand that when you’re calling us, your machine is already down.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.