Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330104-00-08-10-02-00 Proximity Transducer

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330104-00-08-10-02-00.

Exact part330104-00-08-10-02-00 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330104-00-08-10-02-00 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330104-00-08-10-02-00

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330104-00-08-10-02-00
Product Type
Proximity Transducer
Series / Family
3301
Country of Origin
US
Catalog Category
Sensors & Switches
Compliance
API 670 4th Edition
Model confirmed for inquiry 330104-00-08-10-02-00 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330104-00-08-10-02-00 In Stock — Stop the Clock on Your Downtime

Every hour a critical rotating machine sits idle costs real money. On a gas compressor train or steam turbine, unplanned downtime can run $50,000–$200,000 per day in lost production alone — before you factor in emergency labor, expedite freight, and contractual penalties. When the 330104-00-08-10-02-00 proximity transducer is the failed component standing between you and restart, you need a verified unit on a plane today, not a lead-time quote next week.

We stock the Bently Nevada 330104-00-08-10-02-00 in Xiamen and ship globally via DHL Express and FedEx International Priority. Same-day dispatch is available for orders confirmed before 14:00 CST. Our team has handled emergency breakdowns across oil & gas, power generation, and petrochemical plants — we understand what “urgent” actually means on a plant floor.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number 330104-00-08-10-02-00
Brand Bently Nevada (Baker Hughes)
Series 3300 XL Proximity Transducer System
Probe Diameter 8 mm
Extension Cable Length 10 m
Measurement Principle Eddy-current, non-contact displacement
Nominal Output −18 VDC (with compatible 3300 XL driver)
Scale Factor 200 mV/mil (7.87 V/mm)
Linear Range 0–90 mil (0–2.29 mm)
Probe Tip Temperature −35 °C to +177 °C
Ingress Protection IP67
Connector Standard Bently Nevada coaxial (TNC)
Compatible Driver Bently Nevada 330180 Series (3300 XL 8mm)
Compatible Monitor Rack Bently Nevada 3500 Series MPS
Compliance API 670 4th Edition
Country of Origin United States
Availability ✔ Ready to Ship — Xiamen Stock

Troubleshooting & Replacement Tips

The 330104-00-08-10-02-00 fails in predictable ways. Here is what to check before you pull the trigger on a replacement order — and what to watch when you install the new unit.

Common Fault Signatures:

  • OK LED off, −24V rail present: Probe gap out of linear range or probe tip damaged. Check gap with feeler gauge — target 50 mil (1.27 mm) for most shaft applications. Measure probe resistance: should be 7–9 Ω. Open or shorted = replace probe.
  • 3500 rack showing channel fault: Swap the driver (330180) first before condemning the probe. Drivers fail more frequently. If swapping the driver clears the fault, the probe is serviceable.
  • Noisy or erratic vibration signal: Inspect the extension cable (330130 series) for jacket damage at conduit entry points and junction boxes. Any coaxial shield break introduces 50/60 Hz noise directly into the vibration channel.
  • Slow DC gap drift: If drift exceeds 5 mil over a 30-minute warm-up, inspect the probe tip for oil contamination or target surface oxidation. Clean with isopropyl alcohol and re-gap.
  • System 1 showing Transducer Not OK after replacement: The 3300 XL is purely analog — no firmware, no addressing. If the fault persists with a known-good probe and driver, check the junction box for corroded terminals or moisture ingress.

Replacement Procedure (Field-Verified):

  1. Inhibit the trip in the 3500 rack — do not de-energize the rack unless your MOC procedure requires it.
  2. Disconnect the TNC connector at the junction box. Never pull by the cable.
  3. Back the probe out and count the turns — note thread depth for re-gapping the replacement.
  4. Install the new 330104-00-08-10-02-00. Thread to the same depth, then fine-adjust gap while monitoring driver DC output (target: −10 VDC ± 0.5 V for 50 mil gap).
  5. Torque the locknut to 20–25 N·m. Do not over-torque — probe body is stainless, bracket is often aluminum.
  6. Reconnect TNC connector finger-tight plus 1/8 turn. Verify OK LED on driver within 30 seconds.
  7. Remove trip inhibit and confirm channel returns to normal in System 1 before signing off.

Configuration Note: No DIP switches, no address settings, no firmware flashing required. Gap calibration is the only field adjustment. Verify the scale factor label on the driver matches the probe — 200 mV/mil for standard 8mm configuration.

Reliability in Harsh Conditions

The 330104-00-08-10-02-00 probe body is machined from 316 stainless steel — resistant to H₂S, chloride-bearing process fluids, and caustic washdowns common in petrochemical service. IP67 rating means the probe survives full immersion to 1 meter for 30 minutes, which translates to reliable operation through steam leaks, cooling water spray, and high-humidity tropical climates.

There are no internal moving parts. Nothing to loosen, fatigue, or wear out under continuous 24/7 operation. Field installations in offshore compressor trains have logged 8–12 years of continuous service without probe replacement — the limiting factor is almost always the extension cable, not the probe itself.

Temperature cycling is handled by the stainless body’s low coefficient of thermal expansion, keeping the probe-to-target gap stable across the full −35 °C to +177 °C operating range. In high-temperature steam turbine applications approaching the upper limit, route the extension cable away from hot surfaces — the cable is rated to 121 °C and is the thermal weak point of the assembly.

EMI rejection is achieved through the coaxial cable construction and the differential signal architecture of the 3300 XL driver. In practice, the system operates cleanly adjacent to VFDs, large motor starters, and high-current bus bars — environments that defeat many competing eddy-current platforms.

Global Express Logistics

Our warehouse is in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. Typical transit times from confirmed order to delivery:

  • Southeast Asia (Singapore, Thailand, Malaysia, Indonesia): 2–3 business days via DHL Express
  • Middle East (UAE, Saudi Arabia, Qatar, Kuwait): 3–4 business days via FedEx International Priority
  • Europe (Germany, Netherlands, UK, Norway): 3–5 business days via DHL Express
  • North America (USA, Canada, Mexico): 3–5 business days via FedEx International Priority
  • South America (Brazil, Colombia, Argentina): 5–7 business days via DHL Express
  • Australia & New Zealand: 3–4 business days via DHL Express

Every shipment includes commercial invoice, packing list, and certificate of origin for customs clearance. For countries with import restrictions on industrial electronics, documentation is prepared in advance to prevent customs holds. Tracking numbers are issued within 2 hours of dispatch. For emergency breakdowns where every hour counts, contact us on WhatsApp for real-time shipment coordination.

Export classification: HS Code 9031.80. No export license required for standard commercial shipments to most destinations. We have shipped to over 40 countries without customs incident.

Contact Information

Reach our technical sales team directly for quotes, availability, and emergency orders:

© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.