Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330104-00-19-05-01-CN Proximity Transducer

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330104-00-19-05-01-CN.

Exact part330104-00-19-05-01-CN RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330104-00-19-05-01-CN ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330104-00-19-05-01-CN

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330104-00-19-05-01-CN
Product Type
Proximity Transducer
Series / Family
3301
Country of Origin
US
Catalog Category
Sensors & Switches
Compliance
API 670, CE, RoHS
Model confirmed for inquiry 330104-00-19-05-01-CN Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330104-00-19-05-01-CN: Stop the Clock on Your Downtime — Ship Today from Xiamen

Your turbine tripped at 03:00. The DCS is screaming a HIGH-HIGH vibration fault on the radial bearing channel. Maintenance pulled the probe — tip is shorted, Proximitor® output is railed at –2 VDC. You need a verified, drop-in 3300 XL system in your hands before the next scheduled window or you’re looking at another 48-hour forced outage. That’s the situation we exist for.

The Bently Nevada 330104-00-19-05-01-CN is a complete, matched eddy current proximity transducer system — 8 mm probe, 5 m extension cable, 330180 Proximitor® sensor — pre-calibrated at 7.87 V/mm (200 mV/mil). We hold verified stock in Xiamen. DHL Express to most destinations: 2–4 business days. No broker delays, no grey-market risk.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Part Number / SKU 330104-00-19-05-01-CN  ✅ Ready to Ship
Brand Bently Nevada (Baker Hughes)
Series 3300 XL Proximity Transducer System
Measurement Principle Eddy Current — Non-Contact
Probe Tip Diameter 8 mm
Linear Gap Range 0.25 mm – 2.25 mm
Scale Factor 7.87 V/mm (200 mV/mil)
Frequency Response DC – 10,000 Hz (–3 dB)
Supply Voltage –24 VDC nominal
Output Signal –2 VDC to –18 VDC (proportional to gap)
Extension Cable Length 5.0 m (matched, tuned to calibration)
Probe Temp Range –35°C to +177°C
Proximitor® Temp Range –35°C to +85°C
Ingress Protection IP67 (probe assembly)
Compliance API 670, CE, RoHS
Connector (Probe Side) MIL-C-5015
Connector (Proximitor Output) BNC / Terminal Block
Country of Origin USA
Stock Status ✅ In Stock — Ships within 1 business day

Troubleshooting & Replacement Tips

Most common failure modes on the 330104 system — what you’ll actually see in the field:

1. Shorted Probe Tip (Physical Impact / Contamination)
Symptom: Proximitor® output locks at –2 VDC (minimum gap). Monitor card throws a Not OK (NOK) status. Confirm by disconnecting the probe from the extension cable and measuring probe tip impedance — a healthy probe reads approximately 7–8 Ω at 1 MHz. A dead short reads <1 Ω. Replace probe only; reuse extension cable and Proximitor® if they pass bench checks.

2. Open Circuit / Cable Break (Extension Cable Fatigue)
Symptom: Proximitor® output rails at –18 VDC (maximum gap). Common on installations with tight conduit bends or vibrating cable trays. Disconnect extension cable at both ends and perform continuity check on center conductor and shield. If open, replace extension cable — do NOT substitute with a non-matched cable; cable length is part of the calibration.

3. Proximitor® Oscillator Failure (Age / Overvoltage)
Symptom: Output is erratic or fixed regardless of gap change. Swap Proximitor® with a known-good unit while keeping the original probe and cable. If output normalizes, the Proximitor® is the culprit. Note: the 330180 Proximitor® is calibrated as a matched set with the 330104 probe — always replace as a system when in doubt to avoid scale factor drift.

4. Gap Setting After Replacement
This is where most field errors happen. After installing the new probe, set the air gap to the midpoint of the linear range: 1.0 mm ± 0.1 mm. Verify Proximitor® output reads approximately –10 VDC at this gap. If your monitor card shows a different center voltage, check whether the previous installation used a non-standard gap — document and correct it. Do not simply match the old gap without verifying the output voltage.

5. Monitor Card Compatibility Check
The 330104-00-19-05-01-CN is designed for 3300/16 and 3300/20 monitor cards. If you are integrating into a 3500-series rack, verify the monitor card’s input impedance and voltage range before installation. The output range (–2 to –18 VDC) is generally compatible, but SIL-rated loops require formal verification. Do not assume backward compatibility without checking the monitor card datasheet.

6. EMI-Induced Signal Noise
If you see high-frequency noise on the vibration signal after replacement — especially near VFDs or large motor starters — check cable routing. The coaxial extension cable shield must be grounded at one end only (Proximitor® end). Double-grounding creates a ground loop that couples electrical noise directly into the signal. Re-route cable away from power conductors where possible; minimum 150 mm separation from unshielded power cables.

Reliability in Harsh Conditions

The 3300 XL system was not designed for a climate-controlled instrument room. It was built for the bearing housing of a 40 MW steam turbine running at 3,000 RPM in a coastal petrochemical plant — and it has to keep working when the ambient hits 55°C, the humidity is 95%, and the floor is vibrating at 12 mm/s RMS.

The probe assembly carries an IP67 rating, meaning it survives temporary immersion — relevant when steam leaks or wash-down cycles are part of your maintenance routine. The probe body is constructed from 316 stainless steel with a PEEK tip, resistant to the hydrocarbon vapors and H₂S concentrations common in refinery environments. The MIL-C-5015 connector is a military-spec bayonet lock — it does not vibrate loose.

Probe temperature tolerance extends to +177°C, which covers the bearing housing temperatures of most steam turbines and hot-section compressors without requiring heat shields or standoff extensions. The coaxial extension cable uses a fluoropolymer jacket rated for continuous exposure at +200°C — it will not embrittle or crack in high-temperature conduit runs.

The Proximitor® sensor is potted and sealed against moisture ingress. In offshore and coastal installations where salt-laden air accelerates corrosion on terminal blocks and PCBs, the potted construction provides a meaningful service life advantage over open-frame electronics. Units installed in North Sea platform applications have logged >8 years of continuous service without recalibration drift exceeding the API 670 tolerance band.

Vibration immunity is inherent to the non-contact measurement principle — there are no moving parts, no wear surfaces, no contact fatigue. The probe tip generates an electromagnetic field; the shaft passes through it. Mechanical vibration at the probe mounting location does not degrade measurement accuracy as long as the probe body remains rigidly fixed. Use thread-locking compound (Loctite 243 or equivalent) on the probe locknut and verify torque to spec after installation.

Global Express Logistics

Stock is held at our Xiamen warehouse, Fujian Province, China — one of the most logistics-dense export hubs in Asia. We ship daily via DHL Express and FedEx International Priority, with cutoff at 16:00 CST for same-day dispatch on confirmed orders.

Typical transit times from Xiamen:

  • Southeast Asia (Singapore, Thailand, Malaysia): 2–3 business days
  • Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days
  • Europe (Germany, Netherlands, UK): 3–5 business days
  • North America (USA, Canada): 4–6 business days
  • Australia / New Zealand: 3–5 business days

Every shipment includes a full commercial invoice, packing list, and Certificate of Conformance. For regulated installations requiring CITES, REACH, or RoHS documentation, advise at time of order. Export classification: HS Code 9031.80 (precision instruments for measuring). No ITAR restrictions apply to this product.

For critical shutdowns where every hour counts, we offer DHL Express 9:00 and FedEx First Overnight to select destinations — confirm availability when you contact us. We can also coordinate with your nominated freight forwarder on EXW Xiamen terms if your company has a preferred carrier contract.

Packaging: each unit ships in anti-static foam-lined carton with individual probe tip protection cap. Extension cable is coiled to manufacturer-specified minimum bend radius to prevent calibration shift during transit. Proximitor® is bubble-wrapped and secured separately within the same carton.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier