Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
GE In Stock OK

GE IC698CPE010-JU PLC CPU Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for IC698CPE010-JU.

Exact partIC698CPE010-JU RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandGE Part NumberIC698CPE010-JU ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ IC698CPE010-JU

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
GE
Primary Part Number
IC698CPE010-JU
Product Type
PLC CPU Module
Series / Family
PACSystems
Manufacturer
GE (Emerson / GE Vernova)
Country of Origin
US
Catalog Category
PLCs & Controllers
Operating Temp.
0 °C to +60 °C
Humidity
5–95 % RH, non-condensing
Model confirmed for inquiry IC698CPE010-JU Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

GE IC698CPE010-JU PACSystems RX7i CPU — Stop the Bleed, Ship Today

Every hour your line sits idle costs real money. A failed IC698CPE010-JU CPU doesn’t care about your production schedule — but we do. We stock this module in Xiamen, tested and ready to pull from the shelf the moment your purchase order clears. DHL Express to most destinations in 3–5 business days. No lead-time games, no broker markups, no excuses.

⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number IC698CPE010-JU
Platform PACSystems RX7i
Manufacturer GE (Emerson / GE Vernova)
CPU Celeron 300 MHz
User Program Memory 10 MB
Ethernet 1 × 10/100 Mbps — SRTP / Modbus TCP
Serial Ports 2 × RS-232 / RS-485 (configurable)
Backplane Compatibility IC698CHS009 (9-slot) / IC698CHS017 (17-slot)
Operating Temperature 0 °C to +60 °C
Storage Temperature −40 °C to +85 °C
Humidity 5–95 % RH, non-condensing
Power Draw ≤ 13 W (backplane-fed)
Firmware Revision JU (latest validated)
Programming Software Proficy Machine Edition (PME) 9.0+
IEC 61131-3 Languages LD, FBD, ST, IL, SFC
Stock Status ✅ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Swapping an IC698CPE010-JU under pressure is where most engineers make avoidable mistakes. Here’s what ten years of field calls have taught:

1. Firmware revision mismatch is the #1 silent killer. The -JU suffix is the factory firmware stamp. If your failed unit was an earlier revision (e.g., -EF, -GH), the replacement JU will boot fine — but verify your Proficy Machine Edition version supports it. PME 9.0 or later handles JU without issue. Older PME versions may flag a hardware mismatch on first connect; update PME before you pull the old CPU.

2. Flash the program before you pull the rack. Use PME to upload the current program from the failed CPU if it still powers on — even partially. A corrupted CPU can often still serve its program memory over the serial port. Don’t assume the backup on the engineering workstation is current; operators make undocumented changes.

3. Slot addressing is automatic — but verify the backplane. The RX7i uses automatic slot addressing; there are no DIP switches on the CPU itself. However, confirm the backplane (IC698CHS009 or IC698CHS017) is seated correctly and the rack power supply (IC698PSA100 / IC698PSA350) is delivering stable voltage before inserting the new module. A marginal PSU will corrupt the new CPU’s flash on first boot.

4. Ethernet IP assignment. The replacement CPU ships with a blank IP configuration. You must assign the IP via PME’s hardware configuration or via the front-panel serial port using the Station Manager utility. Have the original IP, subnet, and gateway documented before you go on-site — this is not the moment to be hunting through old emails.

5. Common fault codes to know:

  • PLC Fault Table — CPU Hardware Failure (Fault Type 0x0001): Indicates internal CPU self-test failure. Replace the module.
  • I/O Fault — Module Not Responding: Often a backplane connector issue, not the CPU. Reseat I/O modules before condemning the CPU.
  • Ethernet Port Fault: Check the embedded switch port; a damaged RJ45 on the CPU is a common field damage point. Inspect before assuming CPU logic failure.
  • Memory Parity Error: Indicates DRAM degradation. Non-recoverable — module replacement required.

6. Redundancy configurations: If this CPU is part of a hot-standby pair (with IC698CRE020), replace only one unit at a time. Force the standby to active before pulling the primary. After installing the new CPU, allow the redundancy sync to complete (watch the SYNC LED) before returning to normal operation. Rushing this step causes a second unplanned switchover.

Reliability in Harsh Conditions

The IC698CPE010-JU was designed for environments that would destroy consumer-grade electronics. The module carries a 0 °C to +60 °C operating range with storage down to −40 °C — relevant for outdoor substations in northern climates or unheated equipment rooms. Humidity tolerance of 5–95 % RH non-condensing covers coastal petrochemical plants and tropical manufacturing facilities where moisture ingress is a constant threat.

Vibration resistance meets IEC 60068-2-6 test profiles, making it suitable for installation near rotating machinery — compressors, pumps, and press lines where structural vibration is transmitted through the control cabinet. The backplane connector system uses a high-retention card-edge design that maintains contact integrity under continuous vibration loads that would loosen standard DIN-rail terminal blocks over time.

EMC compliance under CE Directive 2014/30/EU and UL 508 listing means the module is validated to operate in electrically noisy environments — VFD-heavy motor control centers, arc furnace facilities, and high-voltage switchgear rooms. The embedded Ethernet port includes hardware-level surge protection rated to IEC 61000-4-5 Level 3, protecting against transients from nearby switching events.

Units sourced through our Xiamen warehouse undergo incoming inspection: power-on verification, communication port functional check, and firmware revision confirmation against factory records. We do not ship modules that have not passed this gate.

Global Express Logistics

Our Xiamen warehouse sits 40 minutes from Xiamen Gaoqi International Airport (XMN), one of China’s primary cargo hubs with daily freighter connections to DHL and FedEx sort facilities in Hong Kong, Shanghai, and Guangzhou. This geography is deliberate — it means your module moves from our shelf to an international flight within hours of order confirmation, not days.

Standard export flow:

  • Day 0 (Order confirmed before 14:00 CST): Module pulled, inspected, packed in anti-static foam with humidity indicator card. Commercial invoice and packing list generated. HS Code 8537.10 declared.
  • Day 0–1: DHL Express or FedEx International Priority pickup. AWB number sent to buyer within 2 hours of handover.
  • Day 2–3: Clears Chinese customs export. Arrives at destination country customs.
  • Day 3–5: Delivered to site in most of Europe, North America, Southeast Asia, and the Middle East. Remote destinations (South America, West Africa) add 1–2 days.

For orders requiring formal export documentation — end-user certificates, ECCN classification confirmation, or letter of credit terms — contact us before ordering. We handle regulated exports routinely and will not delay your shipment with last-minute paperwork surprises.

Freight insurance is included on all shipments above USD 500. Below that threshold, insurance is available on request. We have never had a claim go unresolved.

Contact Information

📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.