Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Mitsubishi Electric In Stock OK

Mitsubishi A3NCPUR21 PLC CPU Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for A3NCPUR21.

Exact partA3NCPUR21 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandMitsubishi Electric Part NumberA3NCPUR21 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ A3NCPUR21

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Mitsubishi Electric
Primary Part Number
A3NCPUR21
Product Type
PLC CPU Module
Series / Family
MELSEC-A
Manufacturer
Mitsubishi Electric
Country of Origin
JP
Catalog Category
PLCs & Controllers
Operating Temp.
0°C to 55°C
Humidity
5% to 95% RH (non-condensing)
Model confirmed for inquiry A3NCPUR21 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

A3NCPUR21 CPU Down? Every Minute Costs You — We Ship Today

Your MELSEC-A line just tripped. The HMI is dark, the operator is on the phone, and maintenance is staring at a dead A3NCPUR21 CPU module. You don’t need a sales pitch — you need a verified unit on a plane tonight. That’s exactly what we do.

The Mitsubishi A3NCPUR21 is the central processing unit for A3N-series base configurations, still running production-critical applications in automotive stamping lines, chemical batch reactors, and port logistics systems across Asia, Europe, and the Americas. When it fails, there is no software workaround. The line stops. We stock genuine A3NCPUR21 units in Xiamen and can have your replacement dispatched via DHL Express within hours of order confirmation — not days, not weeks.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number A3NCPUR21
Manufacturer Mitsubishi Electric
Series MELSEC-A (A3N Platform)
Module Type CPU Unit — Central Processing Module
Compatible Base Unit A3N series base units
Program Language Ladder Diagram (LD) via GX Developer
Memory Backup Battery-backed RAM (program + data retention)
Programming Port RS-232C (SC-09 cable compatible)
Operating Temperature 0°C to 55°C
Storage Temperature -20°C to 75°C
Humidity 5% to 95% RH (non-condensing)
Origin Japan
Stock Status Ready to Ship — Xiamen Warehouse
Condition 100% Original, New or Tested Surplus
Export Documentation Commercial Invoice, Packing List, CO available

Troubleshooting & Replacement Tips

Common failure signatures for A3NCPUR21:

  • RUN LED off, ERROR LED solid red: CPU self-diagnostic failure on power-up. First check the battery voltage — a dead backup battery causes RAM corruption that mimics hardware failure. Replace battery (Mitsubishi Q6BAT or equivalent), clear memory, and reload program before condemning the CPU.
  • Intermittent scan timeout faults (error code 5000–5FFF range): Often caused by excessive I/O module count on the base or a failing power supply module (A61P/A62P). Isolate by removing non-critical I/O cards and cycling power. If the CPU stabilizes, the issue is power budget, not the CPU itself.
  • CPU stuck in STOP mode after program transfer: Confirm the RUN/STOP keyswitch position on the front panel. On A3N bases, the hardware key takes priority over software commands. Also verify the program end instruction (FEND/END) is correctly placed — a missing END instruction will prevent the CPU from entering RUN mode.
  • Communication loss with GX Developer: The A3NCPUR21 uses RS-232C at 9600 baud by default. Confirm SC-09 cable pinout, COM port settings, and that no other software is holding the port. USB-to-serial adapters with FTDI chipsets are generally reliable; Prolific-based adapters frequently cause handshake failures with legacy Mitsubishi CPUs.

Replacement procedure — field checklist:

  1. Back up the existing program via GX Developer (File → Save to PC) before powering down, if the CPU is still partially responsive.
  2. Power down the entire base unit. Do not hot-swap the A3NCPUR21 — the A3N platform does not support live CPU replacement.
  3. Note the DIP switch settings on the existing CPU before removal. The A3NCPUR21 uses DIP switches for station number assignment in multi-CPU or network configurations. Replicate these exactly on the replacement unit.
  4. Seat the replacement CPU firmly into slot 0 of the A3N base. Confirm the module latch clicks into position.
  5. Install a fresh backup battery before first power-up to prevent immediate RAM loss alarms.
  6. Power up and confirm the CPU enters STOP mode cleanly (RUN LED off, no ERROR LED). Then transfer the program from GX Developer and switch to RUN.
  7. Verify all I/O modules are recognized in the system monitor before releasing the line.

Firmware note: The A3NCPUR21 does not have field-upgradeable firmware in the conventional sense. If you are replacing a unit that was running a specific OS version for compatibility with older GX Developer releases, confirm your programming software version matches. Mismatched software versions can cause parameter write errors during initial configuration.

Reliability in Harsh Conditions

The MELSEC-A Series was engineered for the factory floor, not the server room. The A3NCPUR21 carries Mitsubishi Electric’s industrial-grade construction standards, which means it was designed from the ground up to operate where conditions are hostile.

Vibration resistance is built into the PCB mounting and connector design — the module tolerates continuous vibration up to 10–57 Hz at 0.075 mm amplitude and 57–150 Hz at 9.8 m/s², consistent with IEC 61131-2 requirements for industrial controllers. In stamping press environments and compressor rooms where structural vibration is constant, this matters.

Thermal performance is equally robust. The A3NCPUR21 operates continuously at ambient temperatures up to 55°C without derating, making it suitable for control panels in tropical climates, outdoor enclosures with marginal cooling, and furnace-adjacent installations where panel temperatures regularly exceed what consumer-grade electronics can tolerate.

Humidity tolerance up to 95% RH (non-condensing) covers coastal industrial facilities, food processing environments with steam washdown, and paper mills where moisture ingress is a constant concern. The conformal coating on Mitsubishi industrial PCBs provides an additional barrier against corrosive atmospheres — a detail that matters in chemical plants and wastewater treatment facilities.

Electromagnetic compatibility is addressed through Mitsubishi’s shielding and grounding design. The A3NCPUR21 meets CE EMC requirements, providing immunity against the conducted and radiated interference generated by variable frequency drives, welding equipment, and high-current switching loads that share panel space in real industrial installations.

Global Express Logistics

Our dispatch hub is in Xiamen, China — one of the most logistics-connected export cities in Asia, with direct DHL and FedEx gateway access. When you confirm an order, here is exactly what happens:

  • Same-day dispatch: Orders confirmed before 15:00 CST are packed, documented, and handed to the carrier the same business day. Anti-static bag, foam-lined carton, moisture barrier — the module arrives in the same condition it left our warehouse.
  • DHL Express Worldwide: Transit time to most of Europe, Southeast Asia, and the Middle East is 2–4 business days door-to-door. North America typically 3–5 business days. Real-time tracking from pickup to delivery.
  • FedEx International Priority: Available as an alternative for destinations where FedEx has stronger last-mile coverage. We select the fastest option for your specific country unless you specify a preference.
  • Export documentation: Commercial invoice, packing list, and certificate of origin are prepared for every international shipment. For regulated industries or customs-sensitive destinations, we can provide additional documentation on request.
  • Customs clearance support: We declare goods accurately with correct HS codes for industrial electronic components. Our export team has handled shipments to 60+ countries and understands the documentation requirements that prevent customs holds.
  • Emergency freight: For genuine production emergencies, contact us via WhatsApp for same-day courier options including overnight air freight to select destinations.

We understand that a tracking number is not the same as a solution. Our logistics team monitors shipments actively and contacts you proactively if any delay is detected — not after you chase us.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.