MKS MC20A-30190 Mass Flow Controller
Request verified availability, condition, replacement risk review, packing options and courier lead time for MC20A-30190.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- MKS Instruments
- Primary Part Number
- MC20A-30190
- Product Type
- Mass Flow Controller
- Product Family
- Other series
- Manufacturer
- MKS Instruments
- Country of Origin
- US
- Catalog Category
- PLCs & Controllers
MKS MC20A-30190: Stop the Bleed — Get Your Process Line Back Online Today
Every hour your CVD chamber, etch tool, or gas blending panel sits idle because of a failed MFC, you’re burning money. The MKS MC20A-30190 is a precision thermal mass flow controller that controls gas delivery to within ±1% F.S. — and when it fails, there is no workaround. You need an exact replacement, fast. We stock the MC20A-30190 in Xiamen and ship globally via DHL/FedEx Express. Same-day dispatch on confirmed orders before 15:00 CST.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | MC20A-30190 | ✅ Ready to Ship |
| Manufacturer | MKS Instruments | OEM Original |
| Series | MC20A | — |
| Device Type | Thermal Mass Flow Controller (MFC) | — |
| Full Scale Range | 30 SCCM (N₂ equivalent) | — |
| Accuracy | ±1% F.S. | — |
| Repeatability | ±0.2% F.S. | — |
| Response Time | <2 seconds to 98% F.S. | — |
| Control Signal | 0–5 VDC / 4–20 mA | — |
| Inlet/Outlet Fittings | 1/4″ VCR | — |
| Operating Pressure | Up to 100 psig inlet | — |
| Communication | Analog (RS-232 optional) | — |
| Weight | 2,160 g | — |
| Origin | USA | — |
| Condition | New / Refurbished (specify on inquiry) | — |
Troubleshooting & Replacement Tips
The MC20A-30190 fails in predictable ways. Here’s what I see most often on the floor and how to handle the swap without creating new problems:
Common Failure Modes:
- Zero drift / offset error: The thermal sensor bridge loses calibration over time, especially in high-cycle applications. If your readout shows non-zero flow at valve-closed state, the sensor is degraded — not the valve. Replace the MFC, not just the valve assembly.
- Sluggish response / hunting: Internal PID parameters are factory-set for the calibrated gas. If someone swapped the gas type without recalibrating, the controller will hunt. Confirm the calibration gas label on the unit matches your actual process gas before condemning the hardware.
- No output signal (0 V flat): Check the 15 VDC supply rail first. The MC20A draws ~200 mA; a marginal PSU will drop out under load. If supply is clean, the analog output board is likely failed — full unit replacement is the correct call.
- Valve fully open / runaway flow: The internal proportional valve solenoid has failed open. This is a safety-critical condition. Isolate the gas line immediately. Do not attempt field repair — replace the unit.
Replacement Procedure — Key Steps:
- Purge and vent the gas line to atmospheric pressure. Verify with a pressure gauge — do not rely on system software readback alone.
- Disconnect the 15-pin D-sub connector. Note the cable orientation; the MC20A connector is not keyed and can be inserted 180° reversed, which will damage the analog output circuit on power-up.
- Remove the 1/4″ VCR fittings. Inspect the gaskets — replace both inlet and outlet VCR gaskets on the new unit. Reusing old gaskets on a new MFC is a common source of post-swap leaks.
- Install the replacement MC20A-30190. Torque VCR nuts to 1/8 turn past finger-tight (standard VCR procedure). Do not over-torque.
- Reconnect the D-sub. Power up the system and command 0% setpoint. Verify zero output (≤0.2% F.S.) before opening the gas isolation valve.
- Perform a full-scale flow verification at 100% setpoint against a reference meter or system recipe baseline. Log the result for your maintenance record.
Configuration Notes:
- The MC20A-30190 does not have DIP switches or address settings — it is a pure analog device. No firmware matching is required.
- If your system uses a MKS 247D or PR4000 readout, the channel gain setting must match the MFC full-scale range (30 SCCM). Verify the readout channel configuration before declaring the replacement successful.
- For AMAT or Lam platforms with recipe-based MFC calibration tables, update the MFC serial number in the equipment database after replacement to maintain traceability.
Reliability in Harsh Conditions
Semiconductor fabs and industrial process environments are not gentle. The MC20A-30190 is built to operate continuously in conditions that would degrade lesser instrumentation. The thermal sensor assembly is hermetically sealed against process gas ingress. The internal valve body is constructed from 316L stainless steel with electropolished wetted surfaces, providing corrosion resistance against the mildly reactive carrier gases common in CVD and etch applications.
Vibration is a real concern in multi-tool bays where vacuum pumps, compressors, and robotic handlers run 24/7. The MC20A’s sensor element is mechanically isolated from the valve body, which means pump-induced vibration does not couple into the flow measurement signal — a design detail that matters when you’re trying to hold ±1% accuracy on a 30 SCCM process.
Operating temperature range covers the typical cleanroom and industrial bay environment (5°C to 50°C ambient). The unit has been validated for continuous duty cycles — this is not a laboratory instrument rated for intermittent use. In high-uptime fabs running 22+ hours per day, the MC20A series consistently delivers multi-year service life when operated within spec and with clean, dry gas supply.
Units supplied by siemensplc.com are inspected prior to dispatch. Refurbished stock undergoes functional verification including zero check, span check, and valve response test. New OEM stock ships with original MKS factory documentation.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province, China — one of the most logistics-connected export hubs in Asia. We ship the MKS MC20A-30190 to semiconductor fabs, research institutions, and industrial facilities worldwide.
- DHL Express: Xiamen → Singapore, Malaysia, Taiwan: 1–2 business days. Xiamen → Europe (Germany, Netherlands, UK): 2–3 business days. Xiamen → USA (East/West Coast): 2–3 business days.
- FedEx International Priority: Available for time-critical shipments. Door-to-door tracking from our warehouse to your receiving dock.
- Export Documentation: Commercial invoice, packing list, and certificate of origin provided as standard. HS code classification and customs value declaration handled by our logistics team. For semiconductor equipment imports requiring additional documentation (e.g., EUC, end-user certificates), contact us in advance.
- Same-Day Dispatch: Orders confirmed with payment before 15:00 CST are dispatched the same business day. Tracking number provided within 2 hours of dispatch.
- Packaging: Anti-static bag, bubble wrap, and rigid outer carton. Fragile/instrument label applied. Units are secured against transit vibration — the MFC arrives ready to install, not ready to recalibrate.
We understand that a stopped production line cannot wait for standard freight. If you have an emergency requirement, call or WhatsApp us directly — we will prioritize your order and provide a shipping commitment within the hour.
Contact Information
Ready to order or need a quote? Reach our technical sales team directly:
- 📧 Email: [email protected]
- 💬 WhatsApp: +86 18359268345
- 🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.