Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
OPTO 22 In Stock OK

OPTO 22 001818K-AC24-AT Discrete Input Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 001818K-AC24-AT.

Exact part001818K-AC24-AT RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandOPTO 22 Part Number001818K-AC24-AT ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 001818K-AC24-AT

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
OPTO 22
Primary Part Number
001818K-AC24-AT
Product Type
Discrete Input Module
Series / Family
AC 24V Field Replacement
Country of Origin
US
Catalog Category
I/O Modules
Operating Temp.
0°C to +70°C
Compliance
UL Listed, CE Marked
Model confirmed for inquiry 001818K-AC24-AT Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

OPTO 22 001818K-AC24-AT G4 Discrete Input Module — Stop the Clock on Unplanned Downtime

Every minute a production line sits idle costs money. When an AC input module fails in your OPTO 22 G4 rack, the window between fault detection and full restoration is measured in dollars per hour — not abstract risk. The 001818K-AC24-AT is a single-channel, optically isolated AC 24V discrete input module built for the OPTO 22 G4 I/O platform. At siemensplc.com, we maintain verified stock of this module specifically to serve engineers who cannot afford to wait on standard lead times. Same-day dispatch. Global express freight. No procurement delays.

This is not a catalog listing. It is a field-ready supply position backed by a sourcing team that understands what a stopped line actually means to a plant manager at 2 AM.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Part Number 001818K-AC24-AT
Brand OPTO 22
Series G4 I/O
Module Type Discrete AC Input Module (Single Channel)
Input Voltage AC 24V nominal
Isolation Optical isolation — field side fully isolated from logic backplane
Rack Compatibility OPTO 22 G4 racks: G4PB4, G4PB16, G4PB32
Operating Temperature 0°C to +70°C
Compliance UL Listed, CE Marked
Condition New OEM / Tested Refurbished (specify on inquiry)
Stock Status Ready to Ship — Contact for real-time availability
Lead Time (In-Stock) Same-day dispatch for orders confirmed before 14:00 CST
Lead Time (Sourced) 5–10 business days for non-stocked quantities
Weight 1,240 g (packaged)

Troubleshooting & Replacement Tips

The 001818K-AC24-AT fails in predictable ways. Knowing the failure signature before you pull the module saves time on the bench and prevents misdiagnosis.

Common Failure Modes:

  • LED on, no logic signal: The opto-coupler LED is illuminated but the output to the backplane is dead. This is the most common failure — the internal LED degrades over years of AC cycling. The module reads as energized at the field terminal but the controller sees no state change. Replace the module; do not attempt to repair the opto-coupler.
  • Intermittent false triggering: Usually caused by AC line noise coupling into the module input. Before condemning the module, verify field wiring shielding and check for ground loops. If the problem persists after wiring remediation, the module’s internal filter capacitor may have drifted — replace.
  • No LED, confirmed 24VAC at terminals: Check the field wiring polarity and terminal torque first. If voltage is confirmed at the module terminals and the LED is dark, the input bridge rectifier inside the module has failed. Module replacement required.
  • Rack slot fault after insertion: If the controller flags a rack slot fault immediately after installing a replacement module, verify the module is fully seated. G4 modules require firm, even pressure — a partially engaged module will cause backplane communication errors that look like a controller fault, not a module fault.

Replacement Procedure — Key Configuration Checks:

  • No address switches on this module: The 001818K-AC24-AT is a passive input module — it carries no DIP switches or firmware. Slot position in the rack determines its I/O address in the controller map. Confirm the replacement goes into the exact same slot as the failed unit, or update your I/O map accordingly.
  • Verify rack revision: Early G4 racks (pre-2005 manufacture) may have slightly different backplane connector tolerances. If the replacement module feels loose in the slot, inspect the rack connector for bent pins before assuming the module is defective.
  • Controller I/O scan: After replacement, force an I/O rescan from the PAC Project or ioControl software. Some controller configurations cache the last known module state — a rescan clears the cache and confirms the new module is recognized.
  • Field wiring re-termination: Re-torque field terminals to spec (typically 0.5–0.6 Nm for G4 terminal blocks). Loose terminations are responsible for a significant percentage of “new module, same fault” callbacks.
  • Functional test before closing the panel: Apply 24VAC to the field terminals and confirm the LED illuminates and the controller registers a state change before buttoning up the enclosure. Do not skip this step under time pressure.

Reliability in Harsh Conditions

The G4 platform was designed for industrial environments where consumer-grade electronics fail within months. The 001818K-AC24-AT reflects that design philosophy across every operating parameter.

Vibration resistance is built into the module’s mechanical design. The G4 form factor uses a positive-locking rack engagement that resists vibration-induced contact degradation — a common failure mechanism in modules that rely solely on friction fit. Plants running heavy presses, compressors, or conveyor drives report consistent G4 module longevity even in high-vibration bays.

Thermal management is passive and conservative. The 0°C to +70°C operating range covers the vast majority of industrial panel environments without requiring forced cooling. The module’s power dissipation is low by design — the opto-coupler input circuit draws minimal current, which means the module runs cool even in densely populated racks with limited airflow.

Humidity and contamination tolerance is addressed through the module’s conformal coating on the internal PCB. In environments with condensation risk — coastal facilities, food processing plants, or outdoor enclosures — the coating provides a meaningful barrier against moisture-induced leakage currents that would otherwise cause false input states.

Optical isolation is the module’s primary protection mechanism against field-side electrical events. Voltage transients from inductive loads switching on the same AC circuit — solenoids, contactors, motor starters — are blocked at the opto-coupler barrier. The logic backplane never sees the field-side noise. This is why G4 modules outlast non-isolated alternatives in electrically noisy environments.

Global Express Logistics

siemensplc.com ships from Xiamen, China — one of the most logistics-capable export cities in Asia. Xiamen Gaoqi International Airport handles daily freighter departures to major hubs in Europe, North America, Southeast Asia, and the Middle East. This geographic position, combined with established DHL and FedEx commercial accounts, means your replacement module moves from our warehouse to your facility on a predictable, trackable timeline.

Standard Express Delivery Timeframes (from Xiamen):

  • Southeast Asia (Singapore, Thailand, Vietnam, Malaysia): 2–4 business days via DHL Express or FedEx International Priority
  • Europe (Germany, Netherlands, UK, France, Italy): 3–5 business days via DHL Express Worldwide
  • North America (USA, Canada, Mexico): 3–5 business days via FedEx International Priority
  • Middle East (UAE, Saudi Arabia, Qatar): 3–5 business days via DHL Express
  • Australia & New Zealand: 4–6 business days via FedEx or DHL
  • South America (Brazil, Chile, Colombia): 5–8 business days; customs clearance timelines vary by country

Export documentation included with every shipment: commercial invoice, packing list, certificate of origin (Xiamen Customs compliant), and HS code declaration. For buyers requiring specific import documentation — FORM E, EUR.1, or country-specific certificates — notify us at order confirmation and we will prepare accordingly.

All shipments are tracked from dispatch to delivery. Tracking numbers are provided within 2 hours of collection. For urgent shipments, we can arrange Saturday pickup with DHL on request.

Payment is accepted via T/T bank transfer, PayPal, Western Union, and major credit cards. Multi-currency invoicing available in USD, EUR, GBP, and HKD.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.