Phoenix Contact MINI-PS/12-24DC/5-15DC/2 2320018 DC/DC Converter
Request verified availability, condition, replacement risk review, packing options and courier lead time for MINI-PS/12-24DC/5-15DC/2.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Phoenix Contact
- Primary Part Number
- MINI-PS/12-24DC/5-15DC/2
- Product Type
- DC/DC Converter
- Product Family
- Other series
- Manufacturer
- Phoenix Contact
- Country of Origin
- DE
- Catalog Category
- Power Supplies
- Operating Temp.
- -25 °C to +70 °C
MINI-PS/12-24DC/5-15DC/2 (2320018): Stop the Clock on Your Downtime — Ship Today from Xiamen
Every minute a line sits idle costs real money. When your Phoenix Contact MINI-PS/12-24DC/5-15DC/2 fails, you don’t have time to chase a distributor’s lead time. We stock this module at our Xiamen warehouse and dispatch same-day via DHL Express or FedEx International Priority. One call, one part, line back up.
The MINI-PS/12-24DC/5-15DC/2 (Phoenix Contact part number 2320018) is a compact, non-isolated DC/DC step-down converter designed for DIN rail installation inside industrial control cabinets. It accepts a wide 12–24 VDC input — covering both 12 V and 24 V bus architectures without rewiring — and delivers an adjustable 5–15 VDC output at up to 2 A continuous. That makes it the go-to solution for powering 5 V logic rails, sensors, encoders, and field devices directly from a 24 V cabinet bus. It is a workhorse in SIMATIC S7, MELSEC, and CompactLogix installations worldwide, and when it goes down, everything downstream goes with it.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value |
|---|---|
| Manufacturer | Phoenix Contact |
| Part Number | 2320018 |
| Model / SKU | MINI-PS/12-24DC/5-15DC/2 |
| Series | MINI-PS |
| Converter Type | Non-isolated DC/DC Step-Down |
| Input Voltage Range | 12–24 VDC (wide-range) |
| Output Voltage | 5–15 VDC (adjustable via trimmer) |
| Output Current (max) | 2 A continuous |
| Output Power (max) | 30 W |
| Mounting | 35 mm DIN rail (EN 60715) |
| Operating Temperature | -25 °C to +70 °C |
| Protection Class | IP20 |
| Certifications | CE, UL, RoHS |
| Country of Origin | Germany |
| Weight | ~200 g |
| Stock Status | ✅ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
After handling hundreds of MINI-PS failures in the field, here are the patterns that show up repeatedly:
Symptom: Output voltage present but unstable / oscillating
Ninety percent of the time this is a capacitor failure on the output filter stage — a classic wear-out mode after 5–8 years of continuous operation in warm cabinets. The trimmer pot also drifts. Before condemning the module, check the output with a scope: if you see ripple above 200 mV peak-to-peak at 2 A load, the module is done. Replace it; do not attempt to recap in the field.
Symptom: No output, input LED off
Verify input fusing first — the MINI-PS draws inrush on power-up and an undersized fuse will blow silently. Check for 12–24 VDC at the input terminals with a meter. If input is confirmed good and the module is dead, the internal switching transistor has likely failed short-circuit. This is not field-repairable.
Symptom: Output voltage fixed at 5 V, trimmer has no effect
The output voltage trimmer (accessible via a small slot on the front face) has a mechanical stop at 5 V minimum. If the trimmer is already at minimum and you need a higher voltage, confirm you are rotating in the correct direction — clockwise increases voltage on this model. If the trimmer spins freely with no effect, the wiper contact is broken internally. Replace the module.
Replacement procedure — key steps:
- De-energize the 24 VDC bus segment feeding this module. Verify with a meter — do not rely on the cabinet door interlock alone.
- Note the output voltage setting before removal. Photograph the trimmer position or measure the output voltage under load so you can replicate it on the new unit.
- The MINI-PS snaps onto 35 mm DIN rail. Press the spring-loaded clip downward with a flat screwdriver and tilt the module off the rail — do not force it straight off or you will crack the housing.
- On the replacement unit, set the output voltage trimmer to match your recorded value before re-energizing. The factory default is typically 5 VDC; if your system runs at 12 V or 15 V, you must adjust before powering up or you risk damaging downstream 5 V logic.
- There are no DIP switches, firmware, or addressing requirements on this model. It is a passive analog converter — plug in, set voltage, done.
- After energizing, measure output voltage under load (not open-circuit) and confirm ripple is within spec before closing the cabinet.
Common fault codes in host PLCs caused by MINI-PS failure:
Siemens S7: SF/BF LED on CPU, I/O module reporting “supply voltage missing” in diagnostics buffer (event ID 0x39D2). Allen-Bradley: Module status fault bit set in I/O tree, controller log showing “Module Communication Error.” These faults clear immediately on restoration of the 5 V rail — no additional PLC configuration is required after replacement.
Reliability in Harsh Conditions
The MINI-PS/12-24DC/5-15DC/2 is built to Phoenix Contact’s industrial-grade standards, which means it is engineered for environments that would kill consumer-grade electronics within weeks.
Vibration: The module is rated to IEC 60068-2-6 sinusoidal vibration testing — 5–150 Hz, 2 g acceleration. DIN rail mounting provides inherent mechanical damping, but the internal PCB and component mounting are also designed to withstand the continuous low-frequency vibration common in compressor rooms, press lines, and mobile equipment enclosures.
Thermal cycling: Operating range is -25 °C to +70 °C ambient. The switching topology is optimized for high efficiency (minimizing self-heating), and the aluminum heat-spreading baseplate conducts heat to the DIN rail and enclosure. In cabinets running at 55–60 °C ambient — common in summer in non-air-conditioned machine rooms — the module operates within spec without derating, provided airflow is not completely blocked.
Humidity and condensation: IP20 protection covers finger-safe terminal access but is not sealed against moisture ingress. In high-humidity environments (coastal plants, food processing, outdoor enclosures), ensure the cabinet has adequate sealing and consider a desiccant pack if condensation is a recurring issue. The conformal coating on the PCB provides a secondary barrier against occasional moisture exposure.
EMC: CE marking covers both the Low Voltage Directive and the EMC Directive. The module passes EN 61000-4-4 (EFT/burst) and EN 61000-4-5 (surge) immunity tests, making it suitable for installation alongside variable-frequency drives, contactors, and other high-noise switching loads without additional filtering in most installations.
Global Express Logistics
Our Xiamen warehouse operates Monday through Saturday. Orders confirmed before 14:00 CST ship the same day. Here is exactly what happens after you place your order:
- Order confirmation (0–2 hours): You receive a proforma invoice and stock confirmation by email. For urgent orders, call or WhatsApp us directly for real-time confirmation.
- Export documentation (2–4 hours): We prepare the commercial invoice, packing list, and HS code declaration (HS 8504.40 for DC/DC converters). For EU destinations, we include the EUR.1 movement certificate where applicable.
- Carrier handoff (same day): Shipments go out via DHL Express (Worldwide) or FedEx International Priority depending on destination and your preference. Both services offer door-to-door tracking from Xiamen to your facility.
- Transit times (typical): Southeast Asia 1–2 days | Europe 3–5 days | North America 3–5 days | Middle East 3–4 days | Australia 3–4 days.
- Customs clearance: We declare at actual value with full part description. For destinations with import duty concerns, contact us — we can advise on HS classification and provide any supporting documentation your customs broker requires.
- Tracking: AWB number sent by email within 2 hours of carrier pickup. You can track in real time on the DHL or FedEx portal.
For critical shutdowns where every hour counts, tell us when you contact us. We will prioritize your shipment in the pick queue and personally confirm dispatch.
Contact Information
📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.