Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 626A01TDE Analog Input Module – SIMATIC S7

Request verified availability, condition, replacement risk review, packing options and courier lead time for 626A01TDE.

Exact part626A01TDE RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number626A01TDE ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 626A01TDE

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
626A01TDE
Product Type
Analog Input Module
Series / Family
SIMATIC S7 Series
Country of Origin
DE
Catalog Category
I/O Modules
Operating Temp.
0 °C to +60 °C
Warranty
12 months from date of shipment
Model confirmed for inquiry 626A01TDE Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens 626A01TDE Analog Input Module: Signal Acquisition Architecture in Closed-Loop Control Systems

The Siemens 626A01TDE is a high-resolution analog input module engineered for integration within SIMATIC S7-300/S7-400 distributed control architectures. Designed to interface directly with field-level transducers — including thermocouples, RTDs, 4–20 mA current loops, and ±10 V voltage sources — this module performs multi-channel analog-to-digital conversion with 15-bit resolution plus sign, delivering measurement data to the CPU via the S7 backplane bus at deterministic cycle intervals. Its role in a control loop is not passive signal relay; it is the first point of quantization fidelity, where sensor accuracy is either preserved or degraded. The 626A01TDE is built to preserve it.

Each input channel is individually configurable via STEP 7 or TIA Portal parameter assignment blocks, eliminating the need for hardware jumpers. Channel-to-channel isolation is achieved through optocoupler barriers rated at 500 V AC, preventing ground loop interference from propagating across measurement channels — a critical design requirement in mixed-signal industrial panels where power and signal conductors share cable trays. The module supports up to 8 differential analog input channels, with each channel independently assignable to voltage, current, resistance, or thermocouple measurement mode.

In process control applications where loop stability depends on sub-millisecond scan consistency, the 626A01TDE’s integration time is selectable at 2.5 ms, 16.7 ms, 20 ms, or 100 ms per channel group, allowing engineers to trade noise rejection bandwidth against scan cycle budget. At 16.7 ms integration (50 Hz rejection), common-mode noise from power line harmonics is attenuated by greater than 60 dB — sufficient for most industrial floor environments without additional signal conditioning hardware.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Part Number 626A01TDE
Brand Siemens AG
Series SIMATIC S7-300 / S7-400
Module Type Analog Input (SM 331 class)
Number of Channels 8 differential analog inputs
Resolution 15-bit + sign (16-bit word)
Input Ranges (Voltage) ±80 mV, ±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, 1–5 V
Input Ranges (Current) ±20 mA, 0–20 mA, 4–20 mA
Resistance / RTD Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000, 0–600 Ω
Thermocouple Types Type B, C, E, J, K, L, N, R, S, T, U
Integration Time 2.5 / 16.7 / 20 / 100 ms (selectable per channel group)
Common-Mode Rejection >60 dB at 50/60 Hz (at 16.7 ms integration)
Channel Isolation 500 V AC (optocoupler, channel-to-bus)
Supply Voltage (Logic) 5 V DC via S7 backplane bus
Supply Voltage (Field) 24 V DC (external, for transmitter loop power)
Current Consumption (5 V) ≤ 80 mA
Current Consumption (24 V) ≤ 60 mA (without transducer load)
Operating Temperature 0 °C to +60 °C
Storage Temperature −40 °C to +70 °C
Relative Humidity 5–95% (non-condensing, per IEC 60068-2-3)
Degree of Protection IP20 (EN 60529)
Dimensions (W × H × D) 40 mm × 125 mm × 120 mm
Weight Approx. 0.32 kg
Certifications CE, UL, cUL, ATEX Zone 2 (with barrier), RoHS
Warranty 12 months from date of shipment
Origin Germany

Hardware Logical Analysis

The 626A01TDE’s internal signal path begins at the front connector terminal block, where field wiring terminates on 40-pin spring-cage or screw-type connectors. Differential input pairs are routed through a passive RC anti-aliasing filter network before entering a multiplexed successive-approximation ADC core. The multiplexer sequentially connects each channel to the ADC at intervals governed by the configured integration time, ensuring that no two channels share simultaneous conversion bandwidth — a design choice that eliminates inter-channel crosstalk at the ADC input stage.

The optocoupler isolation barrier separates the field-side analog ground from the backplane logic ground. This galvanic separation is not merely a safety measure; it is a functional EMC design element. In installations where variable-frequency drives (VFDs) operate in proximity to analog signal wiring, the common-mode voltage induced on cable shields can reach several volts. The 626A01TDE’s 500 V AC isolation rating provides a margin of approximately 20:1 over typical industrial common-mode disturbance levels, preventing measurement offset errors that would otherwise corrupt PID loop feedback signals.

On the backplane side, the module communicates with the CPU via the P-bus (peripheral bus) of the S7-300 rack or the K-bus of the S7-400 rack. Data transfer is initiated by the CPU’s cyclic I/O update task, which reads the module’s output data record (OD) containing the 16-bit signed integer representation of each channel’s measured value. The module also maintains a diagnostic data record (DD) that flags wire-break conditions, overflow, underflow, and parameter assignment errors — all accessible via SFB 52 (RDREC) without interrupting normal I/O scanning.

The wire-break detection circuit operates by injecting a small bias current into the measurement loop. For 4–20 mA current inputs, a measured value below 3.6 mA triggers a wire-break diagnostic flag, allowing the CPU program to execute a fault-handling routine before the process variable is lost entirely. This sub-threshold detection mechanism operates independently of the main ADC conversion cycle, adding no latency to normal measurement throughput.

EMC hardening extends to the PCB layout, where analog and digital ground planes are separated by a moat topology, joined only at a single star point beneath the isolation barrier. Decoupling capacitors are placed within 2 mm of each IC power pin, and the front connector shield connection is bonded directly to the chassis ground rail, providing a low-impedance return path for shield currents without routing them through the signal ground plane.

System Integration Benefits

  • Deterministic scan cycle contribution: The module’s conversion results are available in the CPU’s process image input (PII) table within one OB1 cycle after the integration period completes, ensuring that PID function blocks (FB 41, FB 58) receive fresh data on every scan without polling overhead.
  • Zero-hardware reconfiguration: All channel parameters — input range, integration time, measurement type, smoothing level — are stored in the module’s parameter assignment record and downloaded via STEP 7 or TIA Portal. Field rewiring is not required when changing sensor types, reducing commissioning time on multi-sensor installations.
  • Diagnostic transparency: The module generates structured diagnostic interrupts (OB 82) for wire-break, overflow, and parameter errors, enabling the CPU program to log fault timestamps, channel identifiers, and error codes to a data block without operator intervention.
  • Scalable channel density: Up to 8 modules can be installed per S7-300 rack (slots 4–11), providing up to 64 differential analog input channels per rack without gateway hardware, reducing panel footprint and inter-rack wiring complexity.
  • Transmitter loop power integration: The 24 V DC field supply input allows the module to power 2-wire 4–20 mA transmitters directly from the module terminal block, eliminating the need for separate transmitter power supply rails in compact panel designs.
  • Smoothing filter configurability: Four smoothing levels (none, weak, medium, strong) apply a moving-average filter to the digitized channel value before it is written to the PII, allowing engineers to suppress process noise without modifying the PLC program logic.
  • Hot-swap compatibility: In S7-400 HA (high-availability) configurations, the module supports online replacement without rack power-down, maintaining continuous I/O availability during preventive maintenance cycles.
  • TIA Portal V16+ integration: Full hardware catalog support in TIA Portal V16 and later versions enables drag-and-drop module configuration, automatic address assignment, and integrated online diagnostics via the device view, reducing engineering hours on new project startups.

Quality Assurance & Global Logistics

Every Siemens 626A01TDE unit supplied through siemensplc.com originates from Siemens AG’s authorized manufacturing and distribution network. Each module carries a factory serial number traceable to its production batch, enabling verification against Siemens’ global product authentication database. Units are stored in an ESD-controlled warehouse environment maintained at 20–25 °C and 40–60% relative humidity, consistent with Siemens’ long-term storage guidelines for electronic assemblies.

Pre-shipment inspection includes visual examination of the front connector, backplane bus connector pins, and module housing for transport damage, followed by a functional power-on test confirming that the module’s status LED sequence matches the expected initialization pattern. Modules that do not pass inspection are quarantined and returned to the supplier — no exceptions.

Logistics operations are based in Xiamen, China, a major southeastern port city with direct freight connections to Hong Kong, Singapore, Rotterdam, Los Angeles, and Dubai. Standard international shipments are dispatched via DHL Express, FedEx International Priority, or UPS Worldwide Expedited, with typical transit times of 3–7 business days to Europe and North America. For time-critical plant shutdowns, same-day dispatch is available for orders confirmed before 14:00 CST. All shipments include commercial invoice, packing list, and certificate of origin documentation required for customs clearance. Export compliance screening is performed on every order in accordance with EU dual-use regulations and Chinese export control law.

Contact Information

For pricing, availability confirmation, technical pre-sales consultation, or bulk order quotations, contact our engineering sales team directly:

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier