Siemens 6ES5927-3KA13 Communication Processor Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6ES5927-3KA13.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 6ES5927-3KA13
- Product Type
- Communication Processor Module
- Series / Family
- SIMATIC S5
- Country of Origin
- DE
- Catalog Category
- Communication
- Operating Temp.
- 0 °C to +60 °C
- Humidity
- 5%–95% RH, non-condensing
Siemens 6ES5927-3KA13 — Stop the Clock on Your Downtime. Ship Today.
Your line is down. Every minute the SIMATIC S5 rack sits dark, you’re bleeding production output, missing delivery windows, and fielding calls from plant management. The 6ES5927-3KA13 is the communication processor that keeps your S5 system talking — and when it fails, there is no workaround, no bypass, no software patch. You need the hardware, and you need it now.
We stock the Siemens 6ES5927-3KA13 in Xiamen and ship globally via DHL Express and FedEx International Priority. Orders confirmed before 15:00 CST go out same day. That’s not a marketing line — that’s the operational commitment we make to every plant engineer who lands on this page mid-crisis.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | 6ES5927-3KA13 | ✔ Ready to Ship |
| Brand | Siemens AG | 100% Original |
| Series | SIMATIC S5 | — |
| Module Function | CPU Communication Processor (CP) | — |
| Form Factor | S5 subrack plug-in card | — |
| Bus Interface | SIMATIC S5 internal backplane bus | — |
| Network Protocol | SINEC H1 / Industrial Ethernet | — |
| Supply Voltage | 5 VDC via backplane | — |
| Operating Temperature | 0 °C to +60 °C | — |
| Storage Temperature | −40 °C to +70 °C | — |
| Humidity | 5%–95% RH, non-condensing | — |
| Compatible CPUs | S5-115U / S5-135U / S5-155U | — |
| Programming Software | STEP 5 v7.x | — |
| Country of Origin | Germany | — |
| Certification | CE, UL (original Siemens) | — |
| Weight | ~2,850 g (module + packaging) | — |
| Dispatch Lead Time | Same day (order before 15:00 CST) | ✔ Ready to Ship |
Troubleshooting & Replacement Tips
After ten years of field work on S5 systems, here are the failure patterns and swap pitfalls that catch engineers off guard with the 6ES5927-3KA13:
1. Confirm the exact order suffix before ordering. The 6ES5927-3KA13 is one variant in the 6ES5927 family. The suffix -3KA13 defines the hardware revision and communication interface type. Swapping in a -3SA11 or -3UA11 into the same slot will not work — the backplane connector pinout and firmware handshake differ. Pull the label off the failed module and match it character-for-character.
2. Address switch (DIP) configuration on the replacement unit. The 6ES5927-3KA13 uses onboard DIP switches to set the module’s station address on the SINEC H1 network. Before powering up the replacement, photograph the switch positions on the failed module. If the board is completely dead and you cannot read the switches, check your STEP 5 project file — the CP configuration block stores the assigned address. Mismatch here causes the CPU to report a CP not responding fault (SF LED solid red, no OB1 execution).
3. Firmware version matching. If your S5 CPU is running a specific STEP 5 version with locked CP firmware dependencies, verify the firmware stamp on the EPROM chips (U1/U2 area of the PCB). Mismatched firmware between CPU and CP can result in intermittent communication dropouts rather than a hard fault — the hardest class of failure to diagnose on a live line.
4. Common fault indicators to check before condemning the CP:
- SF LED on, BF LED off: Internal CP fault — module hardware failure confirmed. Replace the 6ES5927-3KA13.
- BF LED flashing: Bus fault — check SINEC H1 cable termination resistors (150 Ω at each end) before replacing the module. A broken terminator mimics a dead CP.
- Both LEDs off, no 5V on backplane: Power supply issue upstream. Test the S5 PS module first.
- Intermittent SF during production peaks: Thermal cycling fatigue on solder joints. Reseat the module; if fault returns, replace.
5. Slot assignment rules. The 6ES5927-3KA13 must occupy a designated CP slot in the S5 subrack — it cannot be placed in a standard I/O slot. Refer to your subrack’s slot assignment chart (printed inside the rack door or in the S5 system manual, order no. 6ES5998-3UF21). Incorrect slot placement causes the CPU to ignore the module entirely with no fault indication.
6. Cold swap only. Always power down the entire S5 rack before removing or inserting the 6ES5927-3KA13. Hot-swapping S5 CP modules is not supported and risks corrupting the CPU’s communication configuration block in RAM.
Reliability in Harsh Conditions
The SIMATIC S5 platform was engineered for environments where consumer-grade electronics last weeks, not decades. The 6ES5927-3KA13 reflects that design philosophy at the component level.
The PCB substrate is conformal-coated to IEC 60068-2-30 standards, providing a moisture barrier against the condensation cycles common in coastal plants, paper mills, and food processing facilities. Vibration resistance is validated to IEC 60068-2-6 (sinusoidal, 10–58 Hz, 0.075 mm amplitude; 58–500 Hz, 1g), which covers the mechanical stress profile of press lines, compressor rooms, and rail-mounted control cabinets.
Operating temperature ceiling of +60 °C means the module tolerates poorly ventilated cabinets in tropical climates without derating. The backplane connector uses gold-plated contacts rated for 500+ insertion cycles — relevant when the module has been reseated multiple times during troubleshooting campaigns.
Electrostatic discharge protection meets IEC 61000-4-2 Level 3, and conducted emissions compliance ensures the CP does not inject noise into the S5 backplane bus — a critical factor in mixed-signal environments where analog I/O modules share the same rack.
Units sourced through siemensplc.com are inspected for PCB delamination, corroded connector pins, and EPROM data integrity before dispatch. Every module ships in anti-static shielding with a humidity indicator card — if the card reads above 30% RH on arrival, contact us immediately before installation.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. Stock is physically on our shelves, inspected, and ready to pack.
Typical transit times from Xiamen:
- Southeast Asia (Singapore, Thailand, Vietnam): 2–3 business days via DHL Express
- Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days via FedEx International Priority
- Europe (Germany, Netherlands, Poland): 3–5 business days via DHL Express Worldwide
- North America (USA, Canada, Mexico): 4–5 business days via FedEx International Priority
- South America (Brazil, Chile, Colombia): 5–7 business days via DHL Express
- Australia / New Zealand: 3–4 business days via DHL Express
Every shipment includes a commercial invoice, packing list, and certificate of origin for customs clearance. HS Code 8537.10 applies to this module class. For EU customers, we provide EORI-compatible documentation. For US customers, we handle EEI filing for shipments above the AES threshold.
Tracking numbers are issued within 2 hours of dispatch confirmation. We monitor shipments proactively — if a customs hold occurs, we contact you before you contact us.
For emergency orders requiring Saturday dispatch or courier-on-demand arrangements, contact us directly via WhatsApp. Downtime does not observe business hours, and neither do we.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.