Siemens 6ES7135-4FB01-0AB0 Analog Output Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6ES7135-4FB01-0AB0.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 6ES7135-4FB01-0AB0
- Product Type
- Analog Output Module
- Series / Family
- SIMATIC
- Country of Origin
- DE
- Catalog Category
- I/O Modules
- Operating Temp.
- 0 °C to +60 °C
6ES7135-4FB01-0AB0 Down? Every Minute Costs You — We Ship Today
Your ET 200S station just threw a fault. The analog output channel is dead. The control valve is frozen. Production is bleeding money at whatever your line rate is — and your maintenance window closed an hour ago. You don’t need a datasheet lecture right now. You need a replacement module on a plane tonight.
The Siemens 6ES7135-4FB01-0AB0 is a 2-channel analog output module for the SIMATIC ET 200S distributed I/O system. We stock it in Xiamen. It ships DHL Express or FedEx International Priority within hours of order confirmation. Most destinations in Southeast Asia, the Middle East, and Europe receive it in 2–4 business days. No waiting on factory lead times. No grey-market risk. 100% original Siemens hardware, traceable to authorized supply chains.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | 6ES7135-4FB01-0AB0 | ✔ Ready to Ship |
| Series | SIMATIC ET 200S | |
| Module Function | Analog Output | |
| Output Channels | 2 (independently configurable) | |
| Voltage Output Range | ±10 V | |
| Current Output Range | 0–20 mA / 4–20 mA | |
| Resolution | 15-bit + sign | |
| Conversion Time per Channel | 0.8 ms | |
| Load Impedance (Voltage Mode) | ≥ 1 kΩ | |
| Load Impedance (Current Mode) | ≤ 600 Ω | |
| Supply Voltage | 24 V DC via ET 200S power module | |
| Backplane Current Draw | ~50 mA at 5 V DC | |
| Channel Isolation | Galvanic isolation, channel-to-backplane | |
| Operating Temperature | 0 °C to +60 °C | |
| Storage Temperature | −40 °C to +70 °C | |
| Protection Rating | IP20 | |
| Dimensions (W × H × D) | 15 × 81 × 52 mm | |
| Weight | ~100 g | |
| Required Terminal Module | 6ES7193-4CD30-0AA0 (TM-AO2×F) | |
| Compatible Interface Modules | IM 151-1 (PROFIBUS), IM 151-3 PN (PROFINET) | |
| Software | STEP 7 V5.x / TIA Portal V13+ | |
| Origin | Germany |
Troubleshooting & Replacement Tips
Swapping a 6ES7135-4FB01-0AB0 in the field is straightforward if you know the traps. Here’s what ten years of emergency callouts have taught:
1. Verify the terminal module first. The 6ES7135-4FB01-0AB0 requires the TM-AO2×F terminal module (6ES7193-4CD30-0AA0). Plugging it into a TM-E or TM-P terminal module will result in no output and a persistent SF LED — the module isn’t faulty, the mechanical pairing is wrong. Check the color coding on the terminal module rail before pulling the old module.
2. Module addressing is automatic — but confirm the slot. ET 200S uses automatic slot-based addressing. The replacement module will inherit the address of the slot it occupies. No DIP switch setting is required on the module itself. However, if the station was configured with a fixed slot assignment in STEP 7 or TIA Portal, inserting the module into the wrong slot will cause a configuration mismatch fault (SF on IM 151, BF on CPU). Count slots from left to right starting at the interface module.
3. Parameterization is stored in the CPU, not the module. Output type (voltage vs. current), substitute value behavior, and diagnostic enable flags are all downloaded from the CPU project. After hot-swap, the IM 151 will automatically push the stored parameters to the new module within one PROFIBUS/PROFINET cycle. You do not need to re-download the project unless the hardware configuration itself has changed.
4. Common fault codes to know:
- SF LED on module, no BF on IM: Parameterization error or wire break on output channel. Check load impedance — voltage mode requires ≥ 1 kΩ, current mode ≤ 600 Ω. An open-circuit current loop will trigger a wire-break diagnostic.
- BF LED on IM 151 after swap: PROFIBUS address conflict or module type mismatch in hardware config. Confirm the GSD file matches the firmware revision of the new module.
- Output stuck at substitute value (e.g., 0 mA or 0 V): CPU is in STOP mode or the output has been forced to substitute value via diagnostic buffer. Check CPU operating mode and clear any active forcing in the variable table.
- Intermittent output drift: Usually a loose terminal connection on the TM-AO2×F or a ground loop between the analog output common and field device ground. Verify shield termination at one end only.
5. Firmware compatibility. The -0AB0 hardware revision is compatible with all current IM 151 firmware versions. If you are replacing an older -0AA0 variant, the hardware is backward compatible, but verify the GSD file version in your STEP 7 project matches. Mismatched GSD files will cause the IM to report a module type error even though the module is physically correct.
6. Hot-swap procedure. ET 200S supports hot-swap on standard modules. Power down the terminal module’s 24 V supply (not the entire station) before extracting the module to avoid output transients that could damage connected actuators. Re-insert the new module, restore 24 V, and confirm the SF LED extinguishes within 2–3 scan cycles.
Reliability in Harsh Conditions
The 6ES7135-4FB01-0AB0 is built to Siemens’ SIMATIC industrial grade — not consumer-grade electronics dressed up in a DIN rail housing. The module is designed and tested to operate continuously in environments that would kill standard instrumentation within months.
Vibration resistance meets IEC 60068-2-6 (sinusoidal) and IEC 60068-2-27 (shock) standards, making it suitable for installation in machinery cabinets subject to continuous mechanical vibration from compressors, presses, and conveyor drives. The conformal coating on the PCB provides protection against condensation and airborne contaminants — a critical factor in coastal industrial facilities and food processing plants where humidity cycles are aggressive.
The operating temperature ceiling of +60 °C is not a marketing figure — it is a tested, certified limit under full load with both channels active. In practice, a well-ventilated ET 200S cabinet running this module at 40 °C ambient will see junction temperatures well within derating limits, giving you years of reliable service between replacements. The galvanic isolation between output channels and the backplane bus is not just a specification checkbox; it is the primary defense against ground loop currents that corrupt analog signals and, in severe cases, damage the CPU backplane.
Storage temperature down to −40 °C means modules held as critical spares in unheated warehouses or shipping containers in cold climates remain fully functional when pulled into service. No conditioning period required — power up and it works.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. This is not a drop-ship arrangement. Stock is physically on our shelves, inspected, and ready to pack.
Standard dispatch timeline: Orders confirmed before 15:00 CST ship same day. Orders confirmed after 15:00 CST ship next business day. We do not batch orders — each urgent shipment is processed individually.
Carrier options:
- DHL Express Worldwide — 2–4 business days to most of Asia, Middle East, Europe, and North America. Real-time tracking from pickup to delivery.
- FedEx International Priority — 2–3 business days to the US, EU, and Australia. Preferred for time-critical shipments where customs clearance speed matters.
- FedEx International Economy — 4–6 business days for non-urgent replenishment orders where freight cost is the priority.
Export documentation provided with every shipment: Commercial invoice (with accurate HS code 8537.10), packing list, certificate of origin, and — upon request — a material safety data sheet and certificate of conformity. All documents are prepared to minimize customs clearance delays. We have shipped to over 40 countries and understand the documentation requirements for industrial electronics imports in each major market.
For orders requiring same-day courier pickup or special handling (e.g., lithium battery co-shipment restrictions, import permit requirements), contact us directly via WhatsApp for real-time coordination: +86 18359268345.
Contact Information
Production line down? Don’t wait on a contact form. Reach us directly:
- Email: [email protected]
- WhatsApp: +86 18359268345
- Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.