6SE7090-0XX84-2FK0 — Stop the Clock on Your Downtime. Ship Today.
Every minute a SIMOVERT MASTERDRIVES line sits idle costs real money. A failed Power Supply Module (PSM) is one of the most common single-point failures in the 6SE70 series — and it’s also one of the fastest to fix when you have the right part on hand. We stock the Siemens 6SE7090-0XX84-2FK0 in Xiamen and can have it moving toward your facility within hours of order confirmation. No waiting on factory lead times. No broker runaround.
This is the module your maintenance team needs right now. Here’s everything you need to make the call.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | 6SE7090-0XX84-2FK0 ✔ Ready to Ship |
| Manufacturer | Siemens AG |
| Product Series | SIMOVERT MASTERDRIVES (6SE70xx) |
| Module Function | Power Supply Module — DC bus rectifier/supply for inverter units |
| Module Type | PSM (Power Supply Module), booksize / chassis cabinet mount |
| Cooling Method | Forced air, internal fan |
| Protection Rating | IP20 |
| Approx. Weight | 10 kg |
| Country of Origin | Germany |
| Condition | New / Genuine OEM |
| Stock Status | ✔ In Stock — Ready to Ship from Xiamen |
| Dispatch Lead Time | Same day / next business day upon payment |
Troubleshooting & Replacement Tips
After ten years of field work on SIMOVERT MASTERDRIVES systems, these are the failure patterns and swap pitfalls that catch engineers off guard:
Common Fault Codes Pointing to a Failed 6SE7090-0XX84-2FK0:
- F002 / F003 — DC Bus Undervoltage / Overvoltage: If the fault appears at startup or under light load and clears on reset only to return, suspect the PSM’s rectifier bridge or pre-charge circuit before chasing the inverter unit.
- F011 — Power Supply Fault: Direct indicator of PSM internal failure. Check the 24 V auxiliary supply output from the PSM first — a sagging auxiliary rail will cascade faults across the entire drive cabinet.
- F023 — Fan Fault: The internal cooling fan on the 6SE7090-0XX84-2FK0 is a known wear item. Fan failure triggers thermal shutdown within minutes under load. Confirm fan rotation on power-up before condemning the full module.
- A070 / A071 — Overtemperature Warning: Often precedes hard fault. Check heatsink fins for dust blockage and verify cabinet airflow before replacement — a clean module in a choked cabinet will fail just as fast.
Replacement Procedure — Field Checklist:
- De-energize the full drive cabinet and verify DC bus discharge to below 50 V before touching any connections. The DC bus on MASTERDRIVES holds charge for several minutes after mains disconnect — use a calibrated meter, not assumption.
- Document the existing PSM’s DIP switch / jumper settings before removal. The 6SE7090-0XX84-2FK0 uses hardware configuration switches for DC bus voltage range selection and pre-charge timing. Mismatched settings on the replacement unit will cause immediate F002/F003 faults.
- Check firmware compatibility. If the drive cabinet runs a mixed firmware environment (e.g., older inverter units with newer CU boards), confirm the PSM firmware version is within the supported range. Siemens STARTER or DriveMonitor can read the firmware version via PROFIBUS or USS before the old module is pulled.
- Inspect the DC bus bar connections and pre-charge resistor assembly during the swap. A failed PSM often takes the pre-charge resistor with it — a resistor that reads open-circuit will prevent the replacement module from completing its startup sequence.
- After installation, perform a controlled no-load power-up with the inverter units disconnected from the DC bus. Verify DC bus voltage stabilizes at the rated level before reconnecting inverter modules.
- Clear all fault history via the CU (Control Unit) parameter P952 before returning the drive to production. Residual fault logs can mask new faults during commissioning.
Reliability in Harsh Conditions
The 6SE7090-0XX84-2FK0 was designed for the realities of industrial environments — not laboratory conditions. Siemens engineered the SIMOVERT MASTERDRIVES PSM series to operate continuously in conditions that would degrade lesser components:
- Thermal Endurance: Rated for ambient operating temperatures up to 40°C continuous, with derating curves extending usable range to 55°C in controlled cabinet configurations. The internal thermal management system monitors heatsink temperature in real time and adjusts fan speed accordingly.
- Vibration Resistance: Compliant with IEC 60068-2-6 vibration testing standards. The module’s chassis-mount design and captive fastener system maintain electrical integrity under the mechanical stress typical of steel mill, press, and heavy machinery environments.
- Humidity & Condensation: Designed for operation in environments with relative humidity up to 95% non-condensing. Conformal coating on critical PCB assemblies provides additional protection against moisture ingress in high-humidity industrial settings.
- EMC Robustness: Integrated EMC filtering on the AC input side suppresses conducted interference from neighboring equipment — a critical feature in drive cabinets where multiple high-power converters share a common supply.
- Surge & Transient Protection: Input surge protection handles the voltage transients common on industrial mains supplies, protecting the rectifier bridge from damage during utility switching events or nearby motor starts.
Every unit we ship has been stored in climate-controlled conditions and inspected for signs of degradation before dispatch. You are not getting shelf-worn stock.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. Here is how a typical urgent order moves:
- Order Confirmed → Same Day: Unit is pulled from stock, inspected, and packed in anti-static ESD foam within a double-wall export carton. Shipping documents (commercial invoice, packing list, COO) are prepared in parallel.
- Day 1: Shipment handed to DHL Express or FedEx International Priority. Tracking number issued to buyer within 2 hours of pickup.
- Day 2–4 (Most Destinations): Delivery to Southeast Asia, Japan, South Korea, Australia, Middle East, and Europe. North America typically Day 3–5 depending on customs clearance speed.
- Customs Documentation: We prepare complete export documentation including HS code classification, accurate declared value, and ECCN/EAR compliance statements. This minimizes customs hold risk — a common cause of delay with industrial electronics shipments.
- Packaging Standard: Anti-static bag → foam-lined inner box → double-wall export carton. Fragile and ESD-sensitive labels applied. The module arrives in the same condition it left our warehouse.
- Bulk Orders: For orders of 3+ units or combined BOM sourcing, we coordinate consolidated shipments to reduce freight cost without sacrificing speed. Contact us for a freight quote.
We have shipped SIMOVERT MASTERDRIVES components to steel mills in India, automotive plants in Mexico, paper mills in Scandinavia, and petrochemical facilities across the Middle East. Urgent industrial freight is what we do.
Contact Information
Ready to order or need a technical confirmation before you commit? Reach us directly:
- Email: [email protected]
- WhatsApp: +86 18359268345
- Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.