Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6SL3120-1TE13-0AA4 Single Motor Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6SL3120-1TE13-0AA4.

Exact part6SL3120-1TE13-0AA4 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6SL3120-1TE13-0AA4 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6SL3120-1TE13-0AA4

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6SL3120-1TE13-0AA4
Product Type
AC Drive Module
Series / Family
SINAMICS
Country of Origin
DE
Catalog Category
Motor Drives
Warranty
12 months (new units)
Model confirmed for inquiry 6SL3120-1TE13-0AA4 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens 6SL3120-1TE13-0AA4 SINAMICS S120 Single Motor Module 3A Booksize — Stop the Clock on Your Downtime

Every hour a production line sits idle costs real money. When a SINAMICS S120 Single Motor Module fails mid-shift, the pressure to source a verified replacement — fast — falls squarely on the shoulders of the field engineer. The 6SL3120-1TE13-0AA4 is a 3 A continuous-output, booksize-format axis module that slots into the S120 DC bus architecture. It is not a commodity part; lead times from official channels can stretch weeks. siemensplc.com maintains physical stock in Xiamen, China, with same-day pick-and-pack for confirmed orders. That is the difference between a two-day fix and a two-week shutdown.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value
Part Number 6SL3120-1TE13-0AA4
Brand / OEM Siemens AG
Drive Series SINAMICS S120
Module Class Single Motor Module
Form Factor Booksize
Continuous Output Current 3 A
DC Link Voltage 600 V DC
Axis Count 1-axis
Interface DRIVE-CLiQ
Compatible Control Units CU320-2 DP / CU320-2 PN
Commissioning Software Startdrive (TIA Portal V16+), STARTER V5.x
Cooling Method Forced air (internal fan)
Protection Class IP20
Ambient Operating Temp. 0 °C to +40 °C (derated to 55 °C)
Weight Approx. 5 kg
Country of Origin Germany
Stock Status ✔ Ready to Ship — Xiamen, China
Lead Time Same-day dispatch for orders confirmed before 15:00 CST
Warranty 12 months (new units)

Troubleshooting & Replacement Tips

The 6SL3120-1TE13-0AA4 fails in predictable patterns. Knowing them before you pull the module saves commissioning time on the bench and on the floor.

Common Fault Codes That Point to This Module:

  • F30001 / F30002 — DC link overvoltage or undervoltage. Before condemning the module, verify the Line Module output and DC bus capacitor bank. If the bus is clean and the fault persists on this axis only, the internal IGBT gate driver is the likely culprit.
  • F07900 / A07900 — Motor overcurrent. Check motor insulation resistance first (megger test). If the motor is healthy, the current sensing circuit inside the module may have drifted — replacement is the correct action.
  • F01910 — DRIVE-CLiQ communication fault. Swap the DRIVE-CLiQ cable first (most common cause). If the fault follows the module to a different slot, the module’s CLiQ interface chip has failed.
  • F30021 — Ground fault detected. Isolate the motor cable at the module terminals. If the fault clears, the cable or motor winding is the source. If it persists with terminals open, the module’s output stage has an internal ground fault — replace immediately.

Step-by-Step Hot-Swap Procedure:

  1. Initiate a controlled stop via the CU320-2 and confirm all axes are at zero speed. Do not rely on E-stop alone — verify via the drive’s status display.
  2. Isolate and lock out the incoming supply to the Line Module. Measure DC bus voltage at the module terminals and wait for discharge below 50 V DC (typically 5–10 minutes for a 600 V bus).
  3. Photograph the existing DRIVE-CLiQ topology and motor cable routing before disconnecting anything. The S120 topology is order-sensitive; reconnecting CLiQ cables in the wrong sequence will generate F01910 on every axis downstream.
  4. Release the DC bus bar connectors (top and bottom) before removing the module from the rail. These are spring-loaded — use the correct Siemens extraction tool or a flat-blade screwdriver in the release slot. Forcing them damages the bus bar contacts.
  5. Slide the replacement 6SL3120-1TE13-0AA4 onto the mounting rail and engage the bus bar connectors. Confirm the mechanical interlock clicks on both ends.
  6. Firmware check: The replacement module ships with factory firmware. On first power-up, the CU320-2 will detect a firmware mismatch if your system runs a non-standard version. Have a laptop with Startdrive or STARTER ready to push the correct firmware file before going live. Firmware version is visible in the drive’s parameter r0018.
  7. Electronic nameplate (eNP): The S120 system reads the motor data from the encoder’s electronic nameplate via DRIVE-CLiQ. After module swap, perform a “Drive Configuration” in Startdrive to re-read the eNP and confirm motor parameters are correctly loaded into the new module’s memory.
  8. Restore power, clear faults, and run the axis at 10% speed for 2 minutes before returning to full production speed. Monitor current feedback (r0068) and compare against the pre-failure baseline.

Configuration Notes: The 6SL3120-1TE13-0AA4 has no physical DIP switches. All axis addressing is handled automatically by the DRIVE-CLiQ topology scan. However, if you are replacing a module in a multi-axis string, verify that the axis number assignment in the CU320-2 project matches the physical slot position — a mismatch here causes the wrong motor to respond to speed commands, which is a safety-critical error in multi-axis gantry or winding applications.

Reliability in Harsh Conditions

The SINAMICS S120 booksize platform was designed for cabinet-mounted industrial environments, not laboratory conditions. The 6SL3120-1TE13-0AA4 is built to withstand the realities of a production floor: vibration from nearby presses and compressors, ambient temperatures that spike during summer shutdowns, and humidity cycles in coastal or food-processing facilities.

The module’s internal power stage uses IGBT technology with integrated gate driver protection against short-circuit, overtemperature, and desaturation events. The forced-air cooling system is designed for continuous duty at 40 °C ambient, with a derating curve that allows operation up to 55 °C at reduced output current — a critical margin when a cabinet door is left open during emergency maintenance. Conformal coating on the control PCB provides resistance to condensation and airborne contaminants, which is the primary failure mechanism in humid coastal or chemical plant environments. Vibration resistance meets IEC 60068-2-6 test profiles, making the module suitable for installation near heavy stamping or forging equipment without additional isolation mounts.

Units supplied by siemensplc.com are inspected for physical integrity — housing, connector pins, bus bar contacts, and fan operation — before dispatch. Any unit showing signs of thermal stress, arc damage, or label tampering is rejected at incoming inspection. You receive a module that is ready to install, not one that will fail again in 30 days.

Global Express Logistics

Xiamen is one of China’s primary export hubs, with direct freight connections to major industrial centers across Southeast Asia, the Middle East, Europe, and the Americas. siemensplc.com ships exclusively via DHL Express and FedEx International Priority for time-critical orders — both carriers offer next-flight-out options from Xiamen Gaoqi International Airport for declared emergencies.

Standard Express Timeline (from order confirmation):

  • Southeast Asia (Singapore, Thailand, Vietnam, Indonesia): 2–3 business days
  • Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days
  • Europe (Germany, Netherlands, Poland, Turkey): 3–5 business days
  • Americas (USA, Mexico, Brazil, Chile): 4–6 business days
  • Australia / New Zealand: 3–5 business days

Every shipment includes a commercial invoice with correct HS code declaration (HS 8504.40), a detailed packing list, and a certificate of origin where required by the destination country’s customs authority. Multi-currency payment is supported: USD, EUR, HKD, and CNY via T/T bank transfer, PayPal, or trade finance arrangements for qualified buyers. For shipments requiring an export license or end-user certificate, our compliance team handles the documentation — contact us at the time of inquiry to confirm requirements for your country.

For genuine plant-down emergencies, contact us via WhatsApp at +86 18359268345 and mark your message “URGENT — PLANT DOWN.” We will prioritize pick, pack, and carrier booking within 2 hours of payment confirmation during business hours (08:00–18:00 CST, Monday–Saturday).

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.