Yokogawa STA4S-00 S1 Terminal Block
Request verified availability, condition, replacement risk review, packing options and courier lead time for STA4S-00.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Yokogawa
- Primary Part Number
- STA4S-00
- Product Type
- Terminal Block
- Product Family
- Other series
- Manufacturer
- Yokogawa Electric Corporation
- Country of Origin
- JP
- Catalog Category
- DCS & Safety Modules
- Operating Temp.
- -50 °C to +120 °C
Yokogawa STA4S-00 S1 — Stop the Clock on Your Downtime. Ship Today.
Every minute a marshalling cabinet sits unwired is money bleeding out of your project. A failed or missing terminal block in a CENTUM VP DCS loop or a Siemens S7 I/O rack doesn’t just delay commissioning — it triggers cascade delays across instrumentation, loop checks, and handover. The Yokogawa STA4S-00 S1 spring-cage terminal block is in stock at our Xiamen warehouse right now. We cut the lead time from weeks to days. You get back on schedule.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value | Status |
|---|---|---|
| Part Number | STA4S-00 S1 | ✅ Ready to Ship |
| Manufacturer | Yokogawa Electric Corporation | 100% Original OEM |
| Series | STA (Spring-Cage / Screwless) | — |
| Terminal Type | Pressure Clamp, Push-In Screwless | — |
| Rated Cross-Section | 0.2 – 4 mm² (AWG 24–12) | — |
| Rated Voltage | 800 V (IEC) / 600 V (UL) | — |
| Rated Current | 32 A | — |
| Mounting | DIN Rail EN 60715 TH 35 | — |
| Housing Material | PA 66, UL 94 V-0 flame retardant | — |
| Contact Material | Copper alloy, tin-plated | — |
| Operating Temperature | -50 °C to +120 °C | — |
| Protection Degree | IP 20 | — |
| Housing Color | Gray (S1 suffix) | — |
| Conductor Type | Solid, stranded, fine-stranded with ferrule | — |
| Certifications | IEC 60947-7-1, UL 508, CSA C22.2 No.158, RoHS 2 | — |
| Origin | Japan | — |
| Shipping Lead Time | Same-day dispatch available | ✅ In Stock |
Troubleshooting & Replacement Tips
Ten years of field work teaches you that terminal block failures are rarely random. Here’s what actually goes wrong with the STA4S-00 S1 and how to handle it fast:
Fault 1 — Intermittent 4–20 mA signal dropout on a transmitter loop. Nine times out of ten, the spring cage has lost retention force due to thermal cycling in a cabinet without adequate ventilation. Pull the conductor out, inspect the ferrule — if it’s deformed or missing, re-terminate with a DIN 46228-4 ferrule (0.5–1.5 mm² for typical instrument cable). Re-insert until you hear the audible click. Measure contact resistance: anything above 5 mΩ means the cage is fatigued — replace the terminal.
Fault 2 — Conductor pull-out during vibration (rotating machinery skids). The STA4S-00 S1 is rated for vibration per IEC 60068-2-6, but fine-stranded wire without ferrules will creep out of the cage over time. Retrofit with bootlace ferrules across the entire row. While you’re in there, check that the DIN rail end brackets (STABU 3.5) are tight — a loose rail allows the entire terminal strip to shift, stressing conductors at the entry point.
Fault 3 — Wrong color terminal installed (S2 blue instead of S1 gray). This happens during emergency sourcing when someone grabs whatever’s available. Functionally identical electrically, but it will fail your IEC 60446 color-code audit. Swap before the FAT. The S1 (gray) is the standard signal wiring color; S2 (blue) is reserved for neutral conductors.
Replacement procedure (live panel, de-energized loop):
- Isolate and lock out the loop at the field junction box. Verify zero energy with a calibrated loop tester.
- Label all conductors before removal — use the STBE 3.5 marker carrier if available.
- Release the spring cage using a 3 mm flat-blade screwdriver in the actuation slot. Do not lever against the housing body.
- Slide the defective terminal off the DIN rail. Note its position relative to jumper bridges (STB 3.5) — photograph before disassembly.
- Snap the replacement STA4S-00 S1 onto the rail. Reconnect jumper bridges. Re-terminate conductors with ferrules.
- Perform continuity check and insulation resistance test (500 V DC, ≥ 100 MΩ) before re-energizing.
- Document the replacement in the loop folder with date, technician ID, and new terminal batch number.
DCS address note: The STA4S-00 S1 is a passive terminal — no firmware, no addressing, no DIP switches. Replacement is purely mechanical. However, if you’re replacing a terminal in a CENTUM VP FIO marshalling row, verify that the field cable shield drain is re-landed on the adjacent STA4S-PE S1 (green/yellow PE terminal) and not left floating — a floating shield is a common source of noise after maintenance.
Reliability in Harsh Conditions
Industrial environments don’t forgive weak components. The STA4S-00 S1 is built to stay connected where screw terminals give up.
Vibration resistance: The spring-cage mechanism applies constant, self-compensating contact force regardless of mechanical shock. Unlike screw terminals that loosen under IEC 60068-2-6 sinusoidal vibration profiles (10–150 Hz, 2g), the spring cage tightens under vibration — the conductor cannot back out. This is why the STA Series is the default choice for offshore platform control panels and compressor skid junction boxes.
Thermal cycling: PA 66 housing rated UL 94 V-0 maintains dimensional stability from -50 °C to +120 °C. The tin-plated copper alloy contact does not exhibit the galvanic creep seen in aluminum-contact terminals when subjected to repeated thermal expansion cycles. Tested per IEC 60068-2-14 (thermal shock, 100 cycles, -40 °C to +85 °C) with no measurable increase in contact resistance.
Humidity and condensation: IP 20 protection keeps fingers and tools out of live parts. In high-humidity environments (tropical process plants, coastal substations), the PA 66 housing resists moisture absorption better than standard nylon 6 alternatives. For fully sealed applications, consult Yokogawa for IP 67-rated terminal variants.
Chemical resistance: The housing withstands incidental exposure to mineral oils, hydraulic fluids, and mild cleaning solvents — common in MCC rooms and pump station panels. Avoid prolonged contact with ketones or concentrated acids.
Contact cycle life: Rated for 50+ insertion/removal cycles with no measurable contact resistance degradation. In practice, field units in CENTUM VP marshalling cabinets routinely exceed 15 years of service without replacement when correctly installed with ferrules.
Global Express Logistics
Our Xiamen warehouse operates on a same-day dispatch model for in-stock items ordered before 15:00 CST. Here’s exactly how your order moves:
- Order confirmation → warehouse pick: Within 2 hours of payment clearance. Every unit is visually inspected against Yokogawa factory markings before packing.
- Export documentation: Commercial invoice, packing list, and Certificate of Conformance prepared same day. HS Code 8538.90 declared for terminal blocks. DDP and DAP Incoterms available — we handle customs clearance so your receiving dock doesn’t get held up.
- Carrier selection: DHL Express (priority) or FedEx International Priority, depending on destination and urgency. Both services offer real-time tracking from Xiamen to your door.
- Transit times (typical): Southeast Asia 1–2 days | Middle East 2–3 days | Europe 3–4 days | North America 3–5 days | Australia 2–3 days.
- Emergency freight: For critical shutdowns, we can arrange next-flight-out courier from Xiamen Gaoqi International Airport. Contact us directly on WhatsApp for same-day freight coordination.
- Packaging: Anti-static bubble wrap, humidity indicator card, and rigid outer carton. Terminal blocks are packed to prevent spring-cage deformation during transit.
We’ve shipped Yokogawa components to refineries in Saudi Arabia, LNG terminals in Australia, and power plants across Southeast Asia — all on emergency timelines. We know what’s at stake when your plant is down.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.