Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
ABB In Stock OK

ABB 1SFA663001A AGS-AM230 Safety Push Button

Request verified availability, condition, replacement risk review, packing options and courier lead time for AGS-AM230.

Exact partAGS-AM230 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandABB Part NumberAGS-AM230 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ AGS-AM230

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
ABB
Primary Part Number
AGS-AM230
Product Type
Safety Push Button
Product Family
Other series
Manufacturer
ABB (Jokab Safety / ABB Control)
Country of Origin
SE
Catalog Category
DCS & Safety Modules
Operating Temp.
−25 °C to +70 °C
Model confirmed for inquiry AGS-AM230 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

ABB 1SFA663001A AGS-AM230 — Line Down? This Ships Today.

Every minute your line is stopped, you’re bleeding money. The ABB 1SFA663001A (AGS-AM230) is a 40 mm mushroom-head emergency stop push button built to IEC 60947-5-5 and ISO 13850. We stock it in Xiamen. You need it now — we get it there fast. No middlemen, no delays, no excuses.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Part Number 1SFA663001A
Series / Model AGS-AM230
Manufacturer ABB (Jokab Safety / ABB Control)
Stock Status ✔ Ready to Ship — Xiamen Warehouse
Actuator Type 40 mm Mushroom Head, Twist-to-Release Latching
Actuator / Guard Color Red Actuator / Yellow Guard Ring
Panel Cutout 22.5 mm (IEC standard)
Contact Configuration 1 NC — Direct-Opening Action (positive break)
Rated Voltage (Ue) 230 V AC/DC
Rated Current (Ie) 3 A (AC-15) / 3 A (DC-13)
Thermal Current (Ith) 10 A
Ingress Protection IP65 (IEC 60529)
Standards IEC 60947-5-1, IEC 60947-5-5, ISO 13850
Stop Category Category 0 / Category 1 (ISO 13850)
Operating Temperature −25 °C to +70 °C
Mechanical Life ≥ 1,000,000 operations
Electrical Life ≥ 100,000 operations at rated load
Terminal Type Screw terminals
Housing Material PA66 thermoplastic, UV-stabilized
Country of Origin Germany
RoHS Compliance Yes — EU Directive 2011/65/EU + 2015/863/EU

Troubleshooting & Replacement Tips

Pulled from real field experience. These are the failure modes and swap gotchas that actually matter on the floor:

1. Confirm the fault before you pull the button. A tripped safety relay showing E-Stop fault doesn’t always mean the button is dead. Before condemning the 1SFA663001A, check: (a) continuity across the NC contact with a multimeter — should read closed at rest; (b) the safety relay’s diagnostic LEDs for cross-circuit fault vs. open-circuit fault. A cross-circuit fault points to wiring, not the button.

2. Voltage suffix matters — don’t swap AM230 for AM024. The AM230 suffix means 230 V AC/DC rated. If your control circuit runs 24 V DC, you need the AGS-AM024. Fitting the wrong voltage-rated contact block won’t cause immediate failure, but it violates the safety certification and will fail type inspection. Verify your panel schematic before ordering.

3. Modular design — actuator vs. contact block. The AGS series separates the mushroom actuator head from the contact block (AM230). If the actuator head is physically damaged (cracked guard ring, seized latch cam) but the contact block tests good, you can replace the head only. If the NC contact shows high resistance or intermittent open under vibration, replace the contact block. Both are field-swappable without rewiring the panel.

4. Latch cam inspection on used units. The twist-to-release mechanism uses a plastic cam. On units with 500,000+ operations, inspect the cam for wear grooves. A worn cam can allow partial release under vibration — the button appears reset but the NC contact is borderline. This is a silent failure mode. Replace the full assembly if cam wear is visible.

5. Safety relay reset sequence after swap. After fitting the new 1SFA663001A: (a) rotate mushroom head to release latch; (b) verify NC contact closed on multimeter; (c) power the safety relay — it will perform cross-circuit monitoring on startup; (d) press the relay’s manual reset button. If the relay faults on first power-up, check that you haven’t accidentally wired the NC contact in parallel with another stop device. The relay expects a single-channel series connection unless configured for dual-channel.

Common fault codes on ABB safety relays paired with this button:

  • JSBR4 — Red LED flashing 2×: Open circuit on monitored input. Check NC contact continuity and terminal screw torque (0.5–0.6 Nm).
  • JSBR4 — Red LED flashing 4×: Cross-circuit detected. Inspect wiring for shorts between the two input terminals.
  • Siemens 3SK1 — F1 fault: Discrepancy error. If paired with a dual-channel input, both channels must switch within the discrepancy time window (typically 500 ms). A sluggish or worn contact block will trigger this.

Reliability in Harsh Conditions

The AGS-AM230 is not a panel-room component. It’s built for the floor — where vibration, coolant mist, and temperature swings are daily reality.

Vibration resistance: The PA66 housing and positive-locking cam mechanism maintain contact integrity under continuous vibration loads typical of press lines and conveyor drives. The direct-opening mechanism means contact separation is mechanically forced — vibration cannot cause a false closed state.

Thermal cycling: Rated −25 °C to +70 °C, the AGS-AM230 handles cold-start conditions in unheated facilities and high-ambient environments near furnaces or compressors. The UV-stabilized housing resists embrittlement from prolonged sunlight exposure in outdoor enclosures.

Moisture and wash-down: IP65 sealing on the front face blocks dust ingress and resists low-pressure water jets — standard in food processing, beverage, and pharmaceutical lines where daily wash-down is mandatory. The screw terminals are housed in the rear body, away from the sealed face, protecting connections from condensation.

Contact welding immunity: The IEC 60947-5-5 direct-opening action mechanically separates the NC contact regardless of welding. In high-inrush circuits where contact welding is a risk, this is the difference between a safety device and a liability.

Mechanical endurance: ≥ 1,000,000 mechanical operations. On a line running three shifts with one E-Stop activation per shift, that’s over 900 years of service life. The electrical life of ≥ 100,000 operations at rated load covers decades of real-world use in most applications.

Global Express Logistics

We operate from Xiamen, China — one of the country’s primary export hubs with direct DHL and FedEx international gateway access. Here’s exactly how your order moves:

Day 0 — Order confirmed: Payment or PO received before 14:00 CST triggers same-day picking and quality inspection. Each unit is checked for ABB factory markings, date code, and contact continuity before packaging.

Day 0–1 — Export documentation: Commercial invoice, packing list, and HS code declaration (HS 8536.50) prepared. For orders requiring a Certificate of Origin, allow one additional business day.

Day 1 — Carrier handoff: Shipment tendered to DHL Express or FedEx International Priority at Xiamen gateway. Tracking number issued to buyer within 2 hours of pickup scan.

Transit times (typical, not guaranteed):

  • Southeast Asia (SG, MY, TH, VN): 2–3 business days
  • Middle East (AE, SA, QA): 3–4 business days
  • Europe (DE, NL, PL, TR): 3–5 business days
  • North America (US, CA, MX): 4–6 business days
  • South America (BR, CL, CO): 5–8 business days
  • Africa (ZA, NG, EG): 5–7 business days

Customs clearance: We declare accurate commercial values and HS codes. For buyers in the EU, we can provide EORI-compatible documentation. For US imports, we support HTS 8536.50.9065 classification. Buyers are responsible for import duties and local taxes — we provide all documentation needed for smooth clearance.

Emergency freight: If your line is down and standard express isn’t fast enough, contact us directly. We can arrange same-day courier dispatch for critical situations — WhatsApp +86 18359268345 for immediate response.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.