ABB S401M-UCC25 Miniature Circuit Breaker
Request verified availability, condition, replacement risk review, packing options and courier lead time for S401M-UCC25.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- ABB
- Primary Part Number
- S401M-UCC25
- Product Type
- Miniature Circuit Breaker
- Product Family
- Other series
- Manufacturer
- ABB
- Country of Origin
- SE
- Catalog Category
- Relays & Protection
ABB S401M-UCC25 — Stop the Clock on Your Downtime. Ship Today.
Every minute your line is down, you’re bleeding money. A tripped or failed S401M-UCC25 in your distribution board doesn’t wait for procurement cycles. We stock this breaker in Xiamen and ship globally via DHL/FedEx Express — so your panel is back online before the next shift starts. This is not a catalog listing. This is a field-ready replacement, verified, boxed, and ready to move.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Manufacturer | ABB |
| Full SKU | S401M-UCC25 ✅ Ready to Ship |
| Series | S400M UCC |
| Poles | 1-Pole |
| Rated Current | 25A |
| Tripping Characteristic | C-Curve (UCC) |
| Breaking Capacity (Icn) | 10 kA @ 230/400V AC |
| Rated Voltage | 230/400V AC |
| Mounting | 35mm DIN Rail (EN 60715) |
| Module Width | 17.5mm (1 module) |
| Standards | IEC 60898-1 / EN 60898-1 |
| Origin | Germany |
| Stock Status | ✅ In Stock — Ships within 24h |
Troubleshooting & Replacement Tips
After ten years of emergency callouts, here’s what actually goes wrong with the S401M-UCC25 in the field — and what to check before you swap it out:
1. Nuisance Tripping Under Load
The C-curve on this breaker tolerates 5–10× rated current for short durations. If it’s tripping on motor start or transformer inrush, don’t assume the breaker is faulty. Measure your actual inrush current with a clamp meter. If inrush exceeds 250A (10× rated), you need a D-curve variant or a higher-rated frame. Replacing like-for-like without diagnosing the root cause will give you the same trip in 48 hours.
2. Breaker Won’t Reset After Trip
This is almost always a downstream fault that hasn’t cleared. The S401M-UCC25 has a thermal-magnetic trip mechanism — if the bimetal strip is still hot, the breaker physically cannot reset. Wait 3–5 minutes, isolate the downstream circuit, then attempt reset. If it trips again immediately on reset, you have a hard fault (ground fault or short) downstream — do not force it.
3. Replacement Procedure — Step by Step
- De-energize the upstream supply and verify with a voltage tester. Lock out / tag out.
- Document the existing wiring positions — photograph before disconnecting.
- Loosen the terminal screws (top and bottom). The S401M-UCC25 accepts 1–35mm² conductors. Use a flat-blade screwdriver, torque to 2.5 Nm on reinstall.
- Unclip from DIN rail: press down on the DIN rail clip at the bottom of the breaker with a screwdriver, tilt the breaker forward, and lift off.
- Snap the new S401M-UCC25 onto the rail — you’ll hear a positive click. Verify it’s fully seated before reconnecting conductors.
- Reconnect conductors in the same positions. Torque terminal screws to 2.5 Nm. Do not overtighten — the terminal block is zinc alloy and will crack.
- If the breaker is part of a comb busbar system (PS1/13 or PS2/13), verify the busbar pin is fully engaged in the top terminal before energizing.
- Energize upstream supply, switch breaker ON, verify downstream voltage.
4. Accessory Compatibility Check
If the failed breaker had a shunt trip (S2C-UA series) or auxiliary contact (S2C-H6R/L) fitted, these snap-on accessories transfer directly to the replacement unit — no rewiring needed. Verify the accessory clip is fully engaged and the wiring harness connector is seated before energizing.
5. Common Fault Codes in Upstream PLC/SCADA
If your control system is reporting a breaker trip via auxiliary contact feedback, check for: digital input showing 0V when breaker is ON (wiring fault or auxiliary contact failure), intermittent trip signals (loose terminal on auxiliary contact — re-torque to 0.8 Nm), or no trip signal on actual trip (auxiliary contact wired to wrong DI polarity — verify NPN/PNP logic with your PLC input spec).
Reliability in Harsh Conditions
The S401M-UCC25 is not a commercial-grade breaker. It’s built for industrial environments where ambient conditions are hostile and maintenance windows are rare. ABB’s S400M UCC series is rated for continuous operation at ambient temperatures from -25°C to +55°C — derated per IEC 60898-1 above 30°C, but the thermal trip calibration accounts for this. In practice, we’ve seen these breakers installed in outdoor enclosures in Southeast Asian humidity (95% RH, non-condensing) and coastal salt-air environments without accelerated failure when properly enclosed.
Vibration resistance is validated to IEC 60068-2-6: 5–150Hz, 1g. In machine tool and press applications where panel vibration is constant, the DIN rail clip mechanism maintains positive engagement without loosening. The terminal screws use a captive design — they don’t back out under vibration cycles.
The bimetal trip element is hermetically sealed against contamination. In dusty environments (foundries, cement plants, grain handling), the internal mechanism is not exposed to particulate ingress through the terminal openings. However, the external toggle mechanism should be exercised (switched ON/OFF) every 6 months in high-dust environments to prevent mechanical stiffening.
For applications with frequent switching cycles (>1000 operations/year), verify the mechanical endurance rating: the S401M-UCC25 is rated for 20,000 mechanical operations and 10,000 electrical operations at rated current. If your application exceeds this, consider a motor-operated variant with the OE-S motor operator accessory for automated cycling.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. Here’s exactly how your order moves:
- Order confirmed before 14:00 CST: Same-day dispatch. Parts are pulled, inspected, and packed within 2 hours of payment confirmation.
- Packaging: Each S401M-UCC25 ships in original ABB retail packaging, double-boxed with foam insert for transit protection. No loose parts, no repackaged units.
- Carrier selection: DHL Express for Europe, Middle East, and Africa (typical transit 2–4 business days). FedEx International Priority for Americas (3–5 business days). DHL or EMS for Southeast Asia (1–3 business days).
- Customs documentation: Commercial invoice, packing list, and country-of-origin certificate (Germany) provided with every shipment. HS Code 8536.20 declared. We do not under-declare value — all documentation is accurate and compliant.
- Tracking: AWB number sent via email within 1 hour of dispatch. Real-time tracking link provided.
- Emergency freight: For critical shutdowns requiring next-flight-out courier, contact us directly on WhatsApp. We can arrange same-day collection for shipments to major hubs.
We have shipped to over 40 countries. Our average transit time to European destinations is 3 business days from Xiamen. If your plant is down, tell us — we prioritize emergency orders in our dispatch queue.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.