Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Schneider Electric In Stock OK

Schneider Electric 140NOE77111 Ethernet TCP/IP Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for TCP/IP.

Exact partTCP/IP RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSchneider Electric Part NumberTCP/IP ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ TCP/IP

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Schneider Electric
Primary Part Number
TCP/IP
Product Type
Ethernet Communication Module
Series / Family
Modicon Quantum
Manufacturer
Schneider Electric (Modicon)
Country of Origin
FR
Catalog Category
Communication
Operating Temp.
0°C to +60°C
Humidity
5%–95% RH, non-condensing
Model confirmed for inquiry TCP/IP Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

140NOE77111 Down? Every Minute of Downtime Costs You — We Ship Today

Your Modicon Quantum rack just threw a communication fault. The HMI is blind, SCADA polling has stopped, and your shift supervisor is already on the phone. You know the drill: the 140NOE77111 Ethernet TCP/IP module is the single point of failure between your field I/O and the plant network — and right now it’s dead. We’ve been here before. That’s exactly why we stock this module in Xiamen, pre-inspected, boxed, and ready to hand to DHL before your next shift starts.

This is not a listing. This is a recovery plan.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Part Number 140NOE77111  ✅ Ready to Ship
Manufacturer Schneider Electric (Modicon)
Series Modicon Quantum
Module Function Ethernet TCP/IP Network Communication Module
Protocols Supported Modbus TCP/IP, HTTP, SNMP v1, BOOTP/DHCP, EtherNet/IP (adapter mode)
Network Interface 1 × RJ45, 10/100 Mbps, Auto-negotiation, Auto-MDIX
Max TCP Connections 64 simultaneous client/server connections
Backplane Bus Modicon Quantum local bus (standard slot, no special positioning required)
Power Draw 3.5 W from backplane — verify PSU budget before hot-swap
Operating Temperature 0°C to +60°C
Storage Temperature -40°C to +85°C
Humidity 5%–95% RH, non-condensing
Weight 360 g
Certifications CE, UL, cUL, FM Class I Div 2
Firmware Upgrade Via network (Unity Pro / EcoStruxure Control Expert)
Compatible CPUs 140CPU65160, 140CPU67160, 140CPU67261, and all standard Quantum CPUs
Country of Origin France
Stock Status ✅ In Stock — Ships from Xiamen within 24 hours

Troubleshooting & Replacement Tips

After ten years of emergency callouts, here are the failure patterns that show up on the 140NOE77111 — and what to check before you even pull the module:

Fault Code ERR LED solid red / no network link: Nine times out of ten this is a hardware failure on the PHY layer — the RJ45 port’s internal transceiver has died, usually from a voltage spike on the cable run. Swap the module. Don’t waste time reflashing firmware on a dead PHY.

Intermittent Modbus TCP timeouts (SCADA polling drops every few hours): Check your TCP connection count first. If you’re running 60+ simultaneous SCADA clients against a single 140NOE77111, you’re saturating the 64-connection ceiling. The module starts silently dropping the lowest-priority connections. Reduce polling frequency or add a second NOE module to distribute load.

Module powers up but IP address is 0.0.0.0: BOOTP/DHCP request is failing — either your DHCP server isn’t responding on that VLAN, or the module’s MAC address isn’t in the DHCP reservation table. Use Unity Pro’s Ethernet Configuration Tool to assign a static IP directly via the backplane before going live.

Replacement procedure — field checklist:

  • Power down the rack or confirm hot-swap is acceptable for your CPU revision (140CPU65160 supports hot-swap; older CPUs may not).
  • Document the existing IP address, subnet mask, gateway, and SNMP community string from the embedded web server (port 80) before pulling the module.
  • The 140NOE77111 does NOT use DIP switches or rotary address selectors — all addressing is software-configured. No physical jumper settings required.
  • Seat the replacement module firmly into the same backplane slot. The slot position is not fixed by hardware; any standard I/O slot works, but your Unity Pro project references the slot number — keep it identical to avoid reconfiguration.
  • Power up and verify the ACT LED blinks green (network traffic). A solid green ACT with no blink means link is up but no data is flowing — check your SCADA polling configuration.
  • Firmware version: confirm the replacement module’s firmware matches or exceeds the original. Mismatched firmware between the NOE module and CPU firmware can cause subtle Modbus function code rejections. Upgrade via Control Expert if needed.
  • If replacing a 140NOE77100 or 140NOE77101 with the 140NOE77111: the 77111 is the current production revision and is backward-compatible in most configurations, but verify your Unity Pro project’s module catalog entry matches — a catalog mismatch will generate a configuration error on download.

Common fault codes to log before replacement: Note any %MW register values from the NOE’s diagnostic area (typically %MW0.0.0.x in your Quantum project) — these give you the last-known fault code and can confirm whether the failure was hardware or a network event. Useful for your incident report.

Reliability in Harsh Conditions

The Modicon Quantum platform was engineered for environments where consumer-grade hardware lasts weeks, not years. The 140NOE77111 carries that same design philosophy into its network interface layer.

Vibration tolerance is validated to IEC 60068-2-6 standards — the module stays seated and operational on machinery bases where constant mechanical vibration would shake loose lesser hardware. The conformal coating on the PCB provides a barrier against airborne contaminants: oil mist in machining environments, sulfur compounds in wastewater plants, and conductive dust in cement or mining operations.

The operating temperature ceiling of 60°C is not a marketing figure — it’s a tested continuous-operation rating. In panel enclosures without active cooling, ambient temperatures routinely reach 50–55°C during summer production peaks. The 140NOE77111 keeps communicating. The RJ45 port’s surge protection handles the transient voltages that propagate through long cable runs in electrically noisy environments — motor drives, welding equipment, and high-current switching all generate EMI that cheaper modules fail to reject.

Every unit we ship has been stored in climate-controlled conditions and inspected for physical integrity: no bent backplane connector pins, no cracked PCB traces, no corroded RJ45 contacts. We don’t ship modules that have been sitting in a humid warehouse for three years. If it leaves Xiamen, it’s field-ready.

Global Express Logistics

Our warehouse is in Xiamen, Fujian — one of China’s primary export hubs with direct DHL and FedEx gateway access. Here’s what the timeline actually looks like:

  • Order confirmed before 14:00 CST: Same-day dispatch. DHL Express tracking number issued by 18:00 CST.
  • Southeast Asia (Singapore, Thailand, Malaysia, Indonesia): 2–3 business days door-to-door via DHL Express.
  • Europe (Germany, France, Netherlands, UK, Poland): 3–5 business days via DHL Express Worldwide.
  • North America (USA, Canada, Mexico): 3–5 business days via FedEx International Priority or DHL Express.
  • Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days via DHL Express.
  • Australia & New Zealand: 4–5 business days via DHL Express.

All shipments include commercial invoice, packing list, and country-of-origin documentation. For customers requiring formal customs clearance support (HS code 8537.10 for PLC modules), we provide complete export documentation. EXW, FOB Xiamen, and DDP (Delivered Duty Paid) terms are available — specify your preference at order confirmation.

For critical emergency shipments, we can arrange Saturday pickup with DHL in Xiamen. Contact us before 12:00 CST Friday to confirm availability. We’ve shipped to active offshore platforms, remote mining sites, and island facilities — if there’s a DHL or FedEx service point within reach of your facility, we can get this module to you.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier