Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Schneider Electric In Stock OK

Schneider Electric LC1D115M7C AC Contactor

Request verified availability, condition, replacement risk review, packing options and courier lead time for LC1D115M7C.

Exact partLC1D115M7C RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSchneider Electric Part NumberLC1D115M7C ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ LC1D115M7C

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Schneider Electric
Primary Part Number
LC1D115M7C
Product Type
AC Contactor
Series / Family
220V AC Coil 3-Pole
Country of Origin
FR
Catalog Category
Relays & Protection
Operating Temp.
−5°C to +60°C
Model confirmed for inquiry LC1D115M7C Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

LC1D115M7C Down? Every Minute Costs Money — Ship Today from Xiamen Stock

A tripped or burned-out LC1D115M7C doesn’t wait for procurement cycles. When a 115A contactor fails on a running motor circuit, you’re looking at a stalled production line, a cooling tower offline, or a pump station dark — and the clock is running. We stock the Schneider Electric LC1D115M7C in Xiamen and move it the same day you confirm. No lead-time games, no substitutions, no grey-market risk.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number / SKU LC1D115M7C ✅ Ready to Ship
Brand Schneider Electric 100% Original
Series TeSys D
Rated Current (AC-3) 115 A
Coil Voltage 220V AC, 50/60 Hz (M7)
Poles 3-pole main + 1 NO / 1 NC aux
Motor Power @ 400V AC-3 55 kW
Motor Power @ 690V AC-3 90 kW
Utilization Category AC-3, AC-4
Compliance Standard IEC 60947-4-1 / CE
Mounting DIN rail or screw panel
Enclosure Rating IP20 (open type)
Operating Temperature −5°C to +60°C
Weight ≈ 1.36 kg
Origin France
Ship From Xiamen, China ✅ Same-Day Dispatch

Troubleshooting & Replacement Tips

Most common failure modes on the LC1D115M7C in the field:

1. Welded main contacts (AC-4 duty abuse)
If the contactor is used for plugging or inching at full 115A load without derating, the silver-alloy contacts weld shut. Symptom: motor runs continuously even after coil de-energizes. Before fitting the replacement, verify the application duty cycle. If it’s AC-4, you need to derate — check Schneider document MKTED210045EN for the derating curve. Running a 115A contactor at AC-4 without derating will destroy the replacement in the same timeframe.

2. Coil burnout — voltage mismatch
The M7 suffix means 220V AC coil. If your control circuit is 24V DC or 110V AC and someone fitted an M7 by mistake, the coil burns within hours. Confirm control voltage before ordering. The coil suffix map: B7 = 24V AC, BD = 24V DC, M7 = 220V AC, U7 = 240V AC. Swapping coil assemblies in the field is possible on TeSys D — the coil block is a separate replaceable sub-assembly (part: LAD7B106) — but if the main body shows arc damage, replace the full unit.

3. Auxiliary contact block failure
The integrated 1 NO + 1 NC auxiliary contacts handle PLC feedback signals. If your PLC input shows the contactor as permanently open or closed regardless of coil state, the aux block has failed — not necessarily the main contactor. Before condemning the full LC1D115M7C, test continuity across A1–A2 (coil) and across the aux terminals separately. A snap-on LADN11 replacement block costs a fraction of the full contactor.

4. Replacement configuration checklist

  • Confirm coil voltage matches control circuit (M7 = 220V AC). Check nameplate on the failed unit.
  • Verify overload relay pairing: LRD3365 (63–80A) or LRD3375 (70–90A) depending on motor FLA. Do not reuse a tripped overload relay — reset and test, or replace.
  • If part of a star-delta starter: the LC1D115M7C is typically the main (line) contactor. Confirm the star and delta contactors (usually smaller, LC1D40 or LC1D65 range) are intact before energizing.
  • Torque main power terminals to 12–14 N·m. Under-torqued connections at 115A cause resistive heating and premature contact failure.
  • Snap-on accessories (aux blocks, surge suppressors, timer modules) from the failed unit are directly compatible with the replacement — no re-wiring required if the accessory itself is undamaged.
  • After installation, perform a no-load coil energization test before connecting motor load. Confirm aux contact state changes are reflected correctly in the PLC.

5. Common fault codes linked to LC1D115M7C failure

  • Schneider Altivar VFD: OCF (overcurrent fault) or SCF (short circuit fault) triggered by welded contacts holding motor online during a fault condition.
  • Modicon M340/M580 PLC: DI channel stuck HIGH on motor-run feedback — indicates welded NO aux contact.
  • Motor protection relay (Sepam, Micom): Contactor failure alarm when coil energized but main contact continuity not confirmed within the pickup time window — check coil circuit wiring and A1/A2 terminal integrity.

Reliability in Harsh Conditions

The TeSys D platform was not designed for clean-room environments. The LC1D115M7C is validated for the conditions that actually exist in industrial plants: ambient temperatures up to 60°C without derating, humidity up to 95% non-condensing, and vibration resistance per IEC 60068-2-6 (10–150 Hz, 1g). The contact assembly uses a double-break design that physically separates the arc from the contact surface, extending electrical life to over 1.5 million AC-3 operations under rated conditions.

In pump stations and compressor rooms where condensation is a daily reality, the IP20 housing keeps incidental drip and dust from reaching the contact chamber during normal operation. For environments requiring higher ingress protection, the LC1D115M7C can be enclosed in a Schneider NSYPLM or equivalent IP65 enclosure without derating — the contactor’s thermal dissipation at 115A is manageable within a properly sized enclosure with passive ventilation.

Shock resistance per IEC 60068-2-27 (15g, 11ms half-sine) means the unit survives the mechanical impulses common in press rooms, stamping lines, and mobile equipment panels. The DIN rail latch mechanism maintains positive engagement under sustained vibration — a failure point on cheaper alternatives that use single-tab retention.

Global Express Logistics

Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL Express, FedEx International Priority, and UPS Worldwide Express connections. Here’s how a typical urgent order moves:

  • Order confirmed before 14:00 CST: Same-day packaging and handover to carrier.
  • DHL Express to Europe (DE, NL, FR, UK): 2–3 business days door-to-door.
  • FedEx IP to Southeast Asia (SG, MY, TH, VN): 1–2 business days.
  • DHL/FedEx to Middle East (AE, SA, QA): 2–4 business days.
  • UPS/DHL to North America (US, CA): 3–5 business days.
  • Commercial invoice & packing list: Issued same day, HS code 8536.49 for customs clearance.
  • Full tracking: AWB number provided within 2 hours of dispatch. Real-time tracking link shared via email and WhatsApp.

For orders requiring formal export documentation (Form A, EUR.1, or certificate of origin), advise at time of order — we prepare these in parallel with packaging to avoid any delay. Dangerous goods classification does not apply to this product; no special carrier restrictions.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.