Schneider Electric MT16N1 Air Circuit Breaker – Masterpact MT
Request verified availability, condition, replacement risk review, packing options and courier lead time for MT16N1.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Schneider Electric
- Primary Part Number
- MT16N1
- Product Type
- Air Circuit Breaker
- Product Family
- Other series
- Country of Origin
- FR
- Catalog Category
- Sensors & Switches
- Warranty
- 12 months from date of shipment
Schneider Electric MT16N1 — 1600A Air Circuit Breaker in Low-Voltage Power Distribution Architecture
The MT16N1 is a 1600A-rated air circuit breaker (ACB) from Schneider Electric’s Masterpact MT platform, designed for deployment as a main incomer, bus coupler, or feeder protection device in low-voltage main distribution boards (MDB) and industrial switchgear assemblies. Operating within the IEC 60947-2 framework, this device provides overcurrent, short-circuit, and earth-fault protection across three poles at system voltages up to 690V AC, 50/60 Hz. Its role in the control loop is not passive — the MT16N1 is the first line of fault isolation between the upstream transformer or generator and the downstream distribution network, and its response time under fault conditions directly determines the degree of damage limitation to connected equipment.
Within a typical LV power distribution architecture, the MT16N1 sits at the top of the protection coordination hierarchy. Its Micrologic electronic trip unit — available in variants 2.0, 5.0, 6.0, and 7.0 — executes time-current characteristic curves that must be selectively coordinated with downstream MCCBs and MCBs. Incorrect coordination results in non-selective tripping, where a downstream fault causes the MT16N1 to open before the closer protective device, blacking out the entire distribution board rather than isolating the faulted branch. Proper application of the MT16N1 therefore requires careful grading of long-time, short-time, and instantaneous protection thresholds against the downstream protection inventory.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Value |
|---|---|
| Model / SKU | MT16N1 |
| Brand | Schneider Electric |
| Series | Masterpact MT |
| Device Type | Air Circuit Breaker (ACB) |
| Rated Current (In) | 1600 A |
| Number of Poles | 3P |
| Rated Operational Voltage (Ue) | 690V AC |
| Rated Frequency | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000V |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) @ 415V | 50 kA (N-frame) |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 100% Icu |
| Rated Short-Time Withstand Current (Icw) | 50 kA / 1s |
| Trip Unit Compatibility | Micrologic 2.0 / 5.0 / 6.0 / 7.0 |
| Mounting Configuration | Fixed or Drawout (specify at order) |
| Degree of Protection (front face) | IP40 |
| Compliance Standard | IEC 60947-2 |
| Mechanical Endurance | 10,000 operating cycles |
| Electrical Endurance @ In | 6,000 operating cycles |
| Ambient Operating Temperature | -25°C to +70°C (derating applies above +40°C) |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
The MT16N1 employs an arc-chute extinction chamber with deionizing plates arranged to maximize arc elongation and cooling velocity. Under fault conditions, the arc plasma column is forced into the chute by electromagnetic blowout forces proportional to the fault current magnitude — a passive, self-reinforcing mechanism that does not depend on control power availability. This is a critical design distinction from vacuum or SF₆ interrupters: the MT16N1’s air-break technology requires no sealed gas pressure monitoring and eliminates the risk of dielectric failure due to gas leakage in humid or high-altitude environments.
The Micrologic trip unit interface operates on a dedicated low-power internal supply derived from the main current transformers (CTs) embedded in each pole. This CT-powered architecture means the trip unit remains functional even during a complete auxiliary power failure — a non-trivial advantage in emergency generator switchover scenarios where control bus voltage may be momentarily absent. The trip unit’s digital signal processor samples current waveforms at a rate sufficient to detect asymmetric fault signatures and distinguish between inrush transients and genuine overcurrent events, reducing nuisance tripping in motor-heavy distribution systems.
EMC performance is addressed through the physical separation of the power arc chamber from the trip unit electronics, combined with shielded CT secondary wiring routed away from the arc extinction zone. The Masterpact MT frame’s steel enclosure provides inherent magnetic shielding, attenuating radiated interference from the arc event before it reaches the trip unit PCB. This architecture allows the MT16N1 to maintain trip unit integrity during close-in fault interruption — a condition that generates significant broadband electromagnetic noise in the 1 MHz–100 MHz range.
For drawout configurations, the racking mechanism incorporates a positive-locking interlock that prevents the breaker from being racked into the connected position unless the main contacts are confirmed open. A secondary shutter mechanism covers the fixed isolating contacts when the breaker is withdrawn, preventing accidental contact with live busbars during maintenance. These interlocks are mechanical, not electronic, ensuring they remain effective regardless of control circuit status.
System Integration Benefits
- Selective Protection Coordination: The Micrologic trip unit’s independently adjustable long-time (Ir), short-time (Isd), and instantaneous (Ii) thresholds allow precise grading against downstream MCCBs, eliminating non-selective tripping and confining fault isolation to the affected branch only.
- EcoStruxure Power Compatibility: Native integration with Schneider Electric’s EcoStruxure Power architecture enables real-time load monitoring, energy metering (with Micrologic 5.0/6.0/7.0), and predictive maintenance alerts via Modbus RTU or IEC 61850 communication modules.
- Zone Selective Interlocking (ZSI): When paired with compatible Micrologic units, ZSI wiring between upstream and downstream breakers reduces fault clearing time to under 50ms for close-in faults, minimizing arc flash energy and equipment thermal stress.
- Motor Mechanism for Remote Operation: The optional motorized operating mechanism enables remote racking and closing via SCADA or BMS, supporting automated load shedding and restoration sequences without manual intervention at the switchboard.
- Auxiliary Contact Signaling: OF (open/closed), SD (trip indication), SDE (earth fault trip), and SDV (undervoltage trip) auxiliary contacts provide discrete status signals to PLC inputs or relay logic, enabling supervisory systems to log breaker state transitions with millisecond-level timestamp resolution.
- Drawout Isolation for Zero-Downtime Maintenance: The drawout chassis allows the breaker to be withdrawn to the test position — where control circuits remain connected but main contacts are isolated — enabling trip unit testing and secondary injection without de-energizing the distribution board.
- High Icw Rating for Busbar Protection: The 50 kA / 1s short-time withstand rating allows the MT16N1 to hold closed during downstream fault clearance by a faster device, supporting busbar protection schemes where the upstream breaker must remain closed to maintain supply to healthy feeders.
- Standardized Frame Dimensions: Masterpact MT frame dimensions conform to IEC panel cutout standards, allowing direct replacement of end-of-life ACBs from the same generation without panel modification — reducing retrofit engineering cost and downtime.
Quality Assurance & Global Logistics
Every MT16N1 unit supplied through siemensplc.com is sourced as genuine Schneider Electric original equipment. Units are verified against Schneider Electric’s published serial number format and nameplate data prior to dispatch. Physical inspection covers contact surface condition, arc chute integrity, trip unit PCB visual check, and mechanical operation of the opening/closing mechanism under manual actuation. Where factory test certificates are available from the supply chain, these are included in the shipment documentation package.
Outbound logistics are managed from Xiamen, China — a major southeastern port city with direct access to international freight lanes serving Southeast Asia, the Middle East, Europe, and the Americas. Standard export packaging uses wooden crates or reinforced cartons with internal foam blocking to prevent transit shock damage to the arc chute assembly and trip unit. For time-critical requirements, DHL Express and FedEx International Priority services are available with typical transit times of 3–5 business days to most destinations. Sea freight consolidation is available for multi-unit orders where lead time permits. Full export documentation — commercial invoice, packing list, certificate of origin, and bill of lading — is prepared for every international shipment. The 12-month warranty covers manufacturing defects and covers return logistics coordination from the point of delivery.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
{
“@context”: “https://schema.org”,
“@type”: “Product”,
“name”: “Schneider Electric MT16N1 1600A Air Circuit Breaker Masterpact MT”,
“description”: “Schneider Electric MT16N1 Masterpact MT series 1600A air circuit breaker, 3-pole, IEC 60947-2, 690V AC, 50kA breaking capacity, for low-voltage main distribution boards and industrial switchgear.”,
“sku”: “MT16N1”,
“mpn”: “MT16N1”,
“brand”: {“@type”: “Brand”, “name”: “Schneider Electric”},
“manufacturer”: {“@type”: “Organization”, “name”: “Schneider Electric”},
“category”: “Air Circuit Breaker”,
“offers”: {
“@type”: “Offer”,
“priceCurrency”: “HKD”,
“availability”: “https://schema.org/InStock”,
“seller”: {“@type”: “Organization”, “name”: “siemensplc.com”}
}
}
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.