Schneider Electric NSX160N Molded Case Circuit Breaker
Request verified availability, condition, replacement risk review, packing options and courier lead time for NSX160N.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Schneider Electric
- Primary Part Number
- NSX160N
- Product Type
- Molded Case Circuit Breaker
- Product Family
- Other series
- Country of Origin
- FR
- Catalog Category
- Relays & Protection
- Operating Temp.
- -25°C to +70°C
NSX160N Down — Every Minute Costs Money. We Ship Today.
Your Compact NSX tripped hard and won’t reset. The line is cold. Maintenance is standing by. You’ve already burned through your spare and the OEM lead time is three weeks. That’s the exact scenario this page exists for. The Schneider Electric NSX160N is on our shelf in Xiamen right now — verified original, tested, and ready to leave the warehouse the same day you confirm the order.
We’ve handled hundreds of emergency callouts for this exact breaker. The NSX160N is one of the most widely deployed MCCBs in Asian and European industrial infrastructure, which means when it fails, the pressure to restore power is immediate. Don’t waste time chasing distributors who will quote you a lead time. Call or email us now.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Model / SKU | NSX160N | ✔ Ready to Ship |
| Series | Compact NSX | |
| Brand | Schneider Electric | |
| Rated Current (In) | 160 A | |
| Rated Voltage (Ue) | 690 V AC / 500 V DC | |
| Breaking Capacity (Icu) @ 415V | 50 kA | |
| Service Breaking Capacity (Ics) | 100% Icu — 50 kA | |
| Poles | 3P (4P available on request) | |
| Mounting Type | Fixed (non-withdrawable) | |
| Trip Unit Options | TM-D (thermal-magnetic) / Micrologic (electronic) | |
| Standards | IEC 60947-2, EN 60947-2, CE | |
| Degree of Protection | IP40 (front face) | |
| Operating Temperature | -25°C to +70°C | |
| Weight | 1.43 kg | |
| Country of Origin | China / France (batch-dependent) | |
| Dispatch Location | Xiamen, China | ✔ Same-Day Available |
Troubleshooting & Replacement Tips
Ten years of field work tells you that most NSX160N failures fall into four categories. Here’s how to diagnose fast and replace clean.
1. Thermal-Magnetic Trip — Won’t Latch After Reset
If the breaker trips and the handle won’t hold in the ON position, the bimetal strip inside the TM-D trip unit has deformed from sustained overload. This is not a nuisance trip — the trip unit is mechanically fatigued. Do not attempt to force-latch. Replace the entire breaker. Before installing the new unit, verify the downstream load hasn’t increased beyond the 160A rating; a fatigued bimetal is often a symptom of a load creep problem upstream.
2. Instantaneous Magnetic Trip — Fault Current Event
If the breaker tripped on a hard fault (short circuit, ground fault), inspect the arc chutes visually after de-energizing. Carbon tracking on the arc chute walls or a burnt smell from the terminal area means the interrupting chamber has taken a hit. Even if the breaker resets, its Icu rating is no longer guaranteed after a high-energy fault event. Replace it. Log the fault current if your protection relay recorded it — if it exceeded 50kA, you need to upsize to NSX160F (70kA) or NSX160H (100kA).
3. Micrologic Trip Unit — Communication Loss or Fault Code
If your NSX160N is fitted with a Micrologic electronic trip unit and you’re seeing a flashing LED or a fault code on the display, check these first: (a) Confirm the 24V DC auxiliary power supply to the Micrologic unit is stable — a sagging supply causes spurious trips and communication dropouts. (b) Check the RS485 or Modbus wiring for loose terminals; vibration in motor control centers works connections loose over time. (c) If the Micrologic unit itself is the failed component, it can be replaced independently without swapping the entire breaker frame — contact us for Micrologic 2.0 / 5.0 / 6.0 availability.
4. Replacement Configuration Checklist
Before energizing the new NSX160N, run through this list:
- Confirm the trip unit type matches the original (TM-D vs Micrologic). A TM-D frame cannot accept a Micrologic unit without a frame change.
- If using a Micrologic trip unit, verify the protection settings (Ir, Isd, Ii, Ig) are programmed to match the original configuration. Settings are not retained when the trip unit is swapped.
- Check the pole count — fixed 3P and 4P frames are not interchangeable. The 4P version adds a neutral pole; confirm your system neutral routing before ordering.
- Torque the line and load terminals to the specified value (typically 6–8 N·m for 160A lugs). Under-torqued connections cause resistive heating and premature failure.
- If the breaker is mounted in a withdrawable cradle (plug-in version), confirm you are ordering the correct fixed vs. plug-in variant. The fixed frame will not seat in a withdrawable cradle.
- After installation, perform a manual trip test using the test button before energizing the load. Confirm the handle snaps to the tripped position cleanly.
Reliability in Harsh Conditions
The Compact NSX platform was not designed for clean-room environments. It was built for the kind of installations where ambient temperature swings 40 degrees between day and night, where vibration from nearby compressors runs continuously, and where humidity condenses on enclosure walls during seasonal transitions.
The NSX160N carries an operating temperature range of -25°C to +70°C — not a marketing figure, but a tested IEC 60947-2 parameter. The molded case construction uses glass-fiber reinforced thermoplastic that resists deformation under sustained thermal load. The arc chute assembly is rated for repeated interruption duty, not just a single fault event.
In motor control center applications, the breaker is routinely subjected to mechanical shock from contactor switching transients and bus vibration. The NSX160N’s internal mechanism uses a toggle-over-center design that maintains contact pressure independent of vibration amplitude — a critical feature in pump stations and compressor rooms where 50Hz vibration is constant.
For coastal and high-humidity installations, the IP40 front-face rating combined with a sealed enclosure provides adequate protection against condensation ingress. For outdoor or wash-down environments, specify the NSX160N with an IP55 enclosure kit — available as an accessory from our stock.
Every unit we ship has been stored in a climate-controlled warehouse in Xiamen. We do not sell units that have been exposed to uncontrolled storage conditions, flood damage, or field returns without full inspection. Original Schneider Electric packaging with intact holographic seals is standard.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to international freight lanes via Xiamen Gaoqi International Airport and Xiamen Port. This geography is not accidental; it was chosen specifically to minimize transit time to Southeast Asia, the Middle East, Europe, and the Americas.
Standard Express Routing (DHL / FedEx Priority):
- Southeast Asia (Singapore, Thailand, Vietnam, Indonesia): 2–3 business days
- Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days
- Europe (Germany, UK, Netherlands, Poland): 4–5 business days
- North America (USA, Canada): 5–7 business days
- Australia / New Zealand: 4–5 business days
Order Cutoff: Orders confirmed before 14:00 CST are processed for same-day dispatch. Orders confirmed after 14:00 CST ship the following business day.
Export Documentation: Every international shipment includes a commercial invoice, packing list, and certificate of origin. For projects requiring a Schneider Electric certificate of conformity or material test report, request this at the time of order — we will include it in the shipment documentation at no additional charge.
Customs Classification: The NSX160N ships under HS Code 8536.20 (automatic circuit breakers for voltage not exceeding 1,000V). We pre-declare the correct HS code on all shipments to prevent customs delays. For destinations with import duty exemptions on industrial automation components, we can provide supporting documentation upon request.
Tracking: A DHL or FedEx tracking number is issued within 2 hours of dispatch and sent directly to your registered email. For urgent shipments, we provide proactive status updates at each major transit hub.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.