Allen-Bradley 1756-EN2TR/B EtherNet/IP Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for 1756-EN2TR/B.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Allen-Bradley
- Primary Part Number
- 1756-EN2TR/B
- Product Type
- EtherNet/IP Communication Module
- Series / Family
- ControlLogix
- Manufacturer
- Allen-Bradley / Rockwell Automation
- Country of Origin
- US
- Catalog Category
- Communication
1756-EN2TR/B Down? Every Minute of Downtime Costs You — We Ship Same Day
Your ControlLogix rack just lost its network backbone. The HMI is blank, the SCADA historian stopped logging, and your shift supervisor is already on the phone. You know the fault: the 1756-EN2TR/B EtherNet/IP bridge module has failed. You don’t need a lecture on the OSI model right now — you need a replacement module on a plane tonight.
We stock the Allen-Bradley 1756-EN2TR/B in Xiamen. Orders confirmed before 15:00 CST ship the same business day via DHL Express or FedEx International Priority. Most destinations in Southeast Asia receive delivery within 24–48 hours. Europe and North America within 72 hours. That’s the difference between a 4-hour outage and a 4-day production loss.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | 1756-EN2TR/B |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Series | ControlLogix (1756 platform) |
| Module Type | EtherNet/IP Communication Bridge |
| Ports | 2 × RJ-45 (dual-port) |
| Network Topology | Linear / DLR (Device Level Ring) |
| Data Rate | 10/100 Mbps, auto-negotiating |
| Backplane Current | 980 mA @ 5 VDC |
| Operating Temp | 0 °C to 60 °C |
| Storage Temp | -40 °C to 85 °C |
| Chassis Slots | 1 slot (any position) |
| Firmware | Field-upgradeable via ControlFLASH |
| Certifications | UL, CE, cUL, RCM |
| Weight | ~400 g |
| Stock Status | ✅ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
After ten years of field calls, these are the failure patterns I see most often with the 1756-EN2TR/B — and the traps that catch engineers during replacement.
Common Fault Indicators:
- NET LED solid red or alternating red/green: The module has lost its IP address or cannot establish a connection to the EtherNet/IP network. Before condemning the module, verify the managed switch port is not in a blocked STP state — this mimics a dead module.
- OK LED flashing red (1 flash): Self-test failure on power-up. The module’s internal RAM or flash has corrupted. This is a hardware fault — replacement is the only fix.
- OK LED flashing red (2 flashes): Firmware update failed or firmware is incompatible with the current controller revision. Attempt ControlFLASH recovery before swapping hardware.
- DLR ring fault — one port active, one port dead: The /B revision introduced improved ring supervisor logic. If you’re replacing a /A with a /B, the ring supervisor election may shift. Verify your ring supervisor settings in Studio 5000 after swap.
- MSG instruction timeout after replacement: The new module’s IP address must match the original exactly. If DHCP is enabled on the network and the module picks up a new lease, every MSG instruction in your ladder targeting the old IP will fault. Assign a static IP immediately after installation.
Step-by-Step Hot-Swap Replacement Procedure:
- Document the existing module’s IP address, subnet mask, gateway, and chassis slot position from RSLinx or Studio 5000 before pulling power.
- The 1756-EN2TR/B supports hot-swap in a powered chassis — no need to de-energize the rack. Inhibit the module in Studio 5000 first to prevent I/O faults from cascading to the controller.
- Press the module release latch, slide the old module out. Seat the new module firmly until the latch clicks — a partial seat causes intermittent backplane faults that are notoriously difficult to diagnose.
- On first power-up, the module will boot with factory defaults (DHCP enabled). Use BOOTP/DHCP Server utility or RSLinx to assign the correct static IP before the controller attempts to re-establish connections.
- If your network uses DLR topology, confirm the ring supervisor role is correctly assigned after the swap. The /B revision has a different default supervisor priority than /A — check this before closing the ring.
- Verify firmware revision matches the rest of your ControlLogix system. Mismatched firmware between the bridge module and the controller can cause implicit I/O connection drops under load. Use ControlFLASH to update if needed.
- Un-inhibit the module in Studio 5000 and monitor the connection status for 10 minutes under normal production load before signing off.
Revision /A vs /B — What Changed: The /B revision added enhanced DLR ring supervisor capabilities and improved EMI immunity on the backplane interface. It is backward compatible with all 1756 chassis and controllers. No program changes are required when swapping /A for /B.
Reliability in Harsh Conditions
The 1756-EN2TR/B is not a commercial-grade network switch in a PLC chassis — it is an industrial-hardened communication module engineered to operate where standard IT equipment fails within weeks.
The module’s conformal-coated PCB resists condensation and airborne contaminants common in food processing, chemical plants, and coastal facilities. Vibration tolerance meets IEC 60068-2-6 standards, making it suitable for installation adjacent to large motors, compressors, and press machinery where chassis vibration is continuous. The operating temperature ceiling of 60 °C means it handles poorly ventilated electrical rooms and outdoor enclosures in tropical climates without thermal throttling or premature failure.
The dual-port DLR architecture is itself a reliability feature: a single cable break anywhere in the ring does not interrupt communication. The ring supervisor detects the fault within milliseconds and reconfigures the network to a linear topology automatically — your I/O connections stay alive while maintenance locates the damaged cable. This is not a software workaround; it is hardware-level fault tolerance built into the /B silicon.
Units shipped from our Xiamen warehouse are stored in climate-controlled conditions with ESD protection. Each module is inspected for physical integrity, label authenticity, and firmware revision before dispatch. We do not ship modules with cracked housings, corroded connectors, or missing latch mechanisms — these are the details that matter when you’re installing at 2 AM during an emergency shutdown.
Global Express Logistics
Our dispatch hub is located in Xiamen, Fujian Province — one of China’s primary export ports with direct DHL and FedEx gateway access. This is not a drop-ship arrangement. Physical stock sits in our warehouse, inspected and ready.
Shipping Timeline by Region (from order confirmation):
- Southeast Asia (SG, MY, TH, VN, ID): DHL Express — 1 to 2 business days
- Northeast Asia (JP, KR, TW): FedEx International Priority — 1 to 2 business days
- Middle East (AE, SA, QA): DHL Express — 2 to 3 business days
- Europe (DE, NL, FR, UK, PL): DHL Express / FedEx — 3 to 4 business days
- North America (US, CA, MX): FedEx International Priority — 3 to 5 business days
- Australia / New Zealand: DHL Express — 2 to 3 business days
Every shipment includes a commercial invoice, packing list, and HS code declaration (HS 8537.10) pre-completed for customs clearance. For customers in countries with strict import controls on industrial electronics, we can provide a Certificate of Origin upon request. Tracking numbers are issued within 2 hours of dispatch and sent directly to your registered email.
For orders requiring same-day dispatch, contact us via WhatsApp before 14:00 CST. We will confirm stock availability and cut-off time in real time — no automated bots, no ticket queues. You speak directly with the engineer handling your order.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.