Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Allen-Bradley In Stock OK

Allen-Bradley 1756-IC16 PLC Digital Input Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 1756-IC16.

Exact part1756-IC16 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandAllen-Bradley Part Number1756-IC16 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 1756-IC16

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Allen-Bradley
Primary Part Number
1756-IC16
Product Type
PLC Digital Input Module
Series / Family
ControlLogix
Manufacturer
Allen-Bradley / Rockwell Automation
Country of Origin
US
Catalog Category
I/O Modules
Operating Temp.
0°C to 60°C
Model confirmed for inquiry 1756-IC16 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

1756-IC16 In Stock — Every Hour of Downtime Costs You Money. We Ship Today.

Your ControlLogix chassis just threw a fault. The 1756-IC16 is dead. Production is stopped. You’ve already called your local distributor — lead time is 6 weeks. That’s not an option.

We stock the Allen-Bradley 1756-IC16 16-point 48V DC digital input module and ship same-day from Xiamen via DHL Express or FedEx International Priority. Most destinations in Southeast Asia, the Middle East, and Europe receive within 3–5 business days. We’ve done this hundreds of times. We know what’s at stake.

URGENT REQUIREMENT?
📧 Email: [email protected]
📱 WhatsApp: +86 18359268345


Quick Technical Datasheet

Catalog Number 1756-IC16  ✅ Ready to Ship
Manufacturer Allen-Bradley / Rockwell Automation
Platform ControlLogix 1756
Module Type Digital Input (D/I), Sinking
Number of Points 16 inputs
Nominal Input Voltage 48V DC
Input Voltage Range 30–60V DC
Input Current per Point ~8 mA @ 48V DC
ON-State Voltage Min. 30V DC
OFF-State Voltage Max. 10V DC
Input Impedance ~6 kΩ
Isolation Group isolated — 2 groups of 8 points, 250V AC continuous
Response Time (OFF→ON / ON→OFF) ≤ 2 ms (hardware filter disabled)
Backplane Current Draw 120 mA @ 5.1V DC; 3 mA @ 24V DC
Power Dissipation 0.61 W
Operating Temperature 0°C to 60°C
Storage Temperature -40°C to 85°C
Relative Humidity 5–95% non-condensing
Terminal Block 1756-TBCH or 1756-TBS6H (sold separately)
Certifications UL, CE, C-Tick, FM Class I Div 2
Compatible Controllers 1756-L55, L6x, L7x, L8x — RSLogix 5000 v13+ / Studio 5000 v21+
Compatible Chassis All 1756 chassis (4, 7, 10, 13, 17-slot)
Weight ~180 g
Stock Status ✅ In Stock — Ships within 24 hours

Troubleshooting & Replacement Tips

Replacing a 1756-IC16 under pressure is straightforward if you follow the right sequence. Here’s what 10 years of field work has taught us:

Step 1 — Confirm the fault before pulling the module. In Studio 5000, navigate to the I/O tree and check the module’s fault code. A solid red Module Status LED with fault code 16#0001 (connection timeout) or 16#0107 (module not responding) confirms the module itself has failed — not the backplane slot or the controller. Don’t swap a good module chasing a wiring fault.

Step 2 — Export the module configuration before removal. Right-click the 1756-IC16 in the I/O tree → Export Module. Save the .L5X file. This captures your input filter settings, RPI (Requested Packet Interval), and connection type. You’ll import this directly into the replacement module — no manual re-entry.

Step 3 — Hot-swap procedure. The 1756 platform supports hot-swap. Inhibit the module in software first (right-click → Module Properties → Connection → Inhibit Module). This prevents the controller from faulting when you physically remove the module. Pull the RTB (removable terminal block) first — field wiring stays intact. Then eject the module using the top and bottom locking tabs simultaneously.

Step 4 — Seat the replacement. Slide the new 1756-IC16 into the same slot. The backplane connector is keyed — it only seats one way. Apply firm, even pressure until both locking tabs click. Reconnect the RTB. The module will power up and attempt to establish a connection with the controller automatically.

Step 5 — Verify and un-inhibit. Watch the Module Status LED — it should cycle from red to flashing green, then solid green within 10–15 seconds. In Studio 5000, un-inhibit the module. Confirm all 16 input tags are reading correctly against known field device states. Check the input filter configuration matches your original settings (default is 1 ms; telecom applications often use 0 ms for fastest response).

Common fault codes on the 1756-IC16:

  • 16#0001 — Connection request timeout. Check backplane seating and controller firmware compatibility.
  • 16#0107 — Module not responding. Module hardware failure — replacement required.
  • 16#0204 — Ownership conflict. Another controller has an open connection to this module. Check for duplicate I/O tree entries.
  • 16#0315 — Module firmware mismatch. The replacement module’s firmware revision doesn’t match the project. Update firmware via ControlFLASH or accept the revision mismatch in module properties.

Critical configuration note: The 1756-IC16 does not use DIP switches or physical addressing — slot addressing is automatic via the ControlLogix backplane. However, if you’re moving the module to a different slot, you must update the slot number in the I/O tree in Studio 5000 and re-download the program. Failure to do this results in a persistent connection fault even with a fully functional module.


Reliability in Harsh Conditions

The 1756-IC16 was engineered for environments where consumer-grade electronics fail within weeks. The module’s conformal-coated PCB resists moisture ingress and condensation — critical in coastal process plants, offshore platforms, and tropical climates where humidity regularly exceeds 80% RH. The group isolation architecture (two isolated groups of 8 points at 250V AC continuous) protects the entire module from ground loops and common-mode voltage spikes that routinely destroy non-isolated I/O in power generation and water treatment applications.

Vibration tolerance meets IEC 68-2-6 standards — the module remains fully operational on machinery with continuous vibration profiles up to 5g across 10–500 Hz. In mining and heavy manufacturing environments where conveyor drives and crushers generate constant structural vibration, this matters. The backplane connector uses a positive-locking mechanism that maintains contact integrity under shock loads up to 30g (IEC 68-2-27).

Thermal performance is equally robust. The module operates continuously at 60°C ambient without derating — no forced cooling required in standard 1756 chassis configurations. In high-density chassis installations where adjacent modules generate significant heat, the 1756-IC16’s low power dissipation (0.61 W) means it contributes minimally to chassis thermal load, extending the service life of neighboring modules.

The 48V DC input voltage range (30–60V DC operational) provides inherent noise immunity advantages over 24V DC systems. In environments with heavy motor drives, VFDs, and switching power supplies generating conducted EMI, the higher signal voltage means a better signal-to-noise ratio at the input threshold — fewer spurious trips, fewer nuisance faults, more stable production.


Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. When you confirm an order before 3:00 PM CST, the module ships the same business day. No exceptions.

Typical transit times from Xiamen:

  • Southeast Asia (Singapore, Thailand, Malaysia, Indonesia): 2–3 business days via DHL Express
  • Middle East (UAE, Saudi Arabia, Qatar, Kuwait): 3–4 business days via FedEx International Priority
  • Europe (Germany, Netherlands, UK, France): 4–5 business days via DHL Express Worldwide
  • North America (USA, Canada, Mexico): 4–6 business days via FedEx International Priority
  • Australia & New Zealand: 3–5 business days via DHL Express
  • South America (Brazil, Chile, Colombia): 5–7 business days via FedEx

Every shipment includes a commercial invoice, packing list, and certificate of origin — all export documentation required for customs clearance is prepared in-house. For customers in countries with strict import controls on industrial electronics, we have experience navigating customs requirements in over 40 countries and can advise on HS code classification (HS 8537.10 for this module) and any applicable import duties.

Shipment tracking is provided in real-time via DHL or FedEx tracking numbers issued at the time of dispatch. For critical emergency shipments, we offer a dedicated logistics coordination service — we monitor your shipment through customs clearance and proactively resolve any holds or documentation requests to prevent delays.

All modules are packed in anti-static ESD bags, placed in foam-lined rigid boxes, and outer-packed in double-wall corrugated cartons rated for international air freight handling. The 1756-IC16 arrives at your facility in the same condition it left ours.


Contact Information

Production stopped? Don’t wait. Reach us directly:

📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier