Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Allen-Bradley
- Primary Part Number
- 2711P-B15C22D9P
- Product Type
- HMI Terminal
- Series / Family
- PanelView
- Country of Origin
- US
- Catalog Category
- HMI Panels
- Operating Temp.
- 0 °C to +55 °C (32 °F to 131 °F)
- Warranty
- 12 months from date of shipment
Allen-Bradley 2711P-B15C22D9P PanelView Plus 7 — Operator Interface Architecture in Process-Critical Control Loops
The 2711P-B15C22D9P is a 15-inch widescreen graphic terminal within Rockwell Automation’s PanelView Plus 7 Standard product family. It occupies the operator interface layer of a control architecture, serving as the primary human-machine boundary between field-level I/O data and plant personnel. Unlike thin-client display solutions, this unit integrates a self-contained Windows Embedded Standard 7 runtime environment, a dual-port EtherNet/IP managed switch, and a resistive analog touch panel into a single NEMA 4/4X-rated enclosure — eliminating the need for a separate panel PC, external switch, or IP-rated enclosure modification.
In a typical ControlLogix or CompactLogix topology, the 2711P-B15C22D9P connects directly to the plant Ethernet backbone via its embedded DLR (Device Level Ring) capable ports. The terminal polls tag data from the controller’s data table at configurable scan rates, renders graphic faceplates, and writes operator setpoints back to the controller — all within a deterministic communication cycle governed by the EtherNet/IP implicit messaging protocol. This architecture keeps HMI processing load off the controller backplane, preserving scan time budget for ladder logic execution.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Catalog Number | 2711P-B15C22D9P |
| Display Size | 15.0 in (381 mm) diagonal, color TFT LCD |
| Display Resolution | 1024 × 768 (XGA) |
| Touch Technology | Analog resistive, single-touch |
| Processor | Intel Atom E3827, 1.75 GHz dual-core |
| RAM | 1 GB DDR3 |
| Non-volatile Storage | 4 GB industrial-grade Flash |
| Operating System | Windows Embedded Standard 7 (WES7) 32-bit |
| HMI Runtime | FactoryTalk View ME v9.0 or later |
| Communication Ports | 2 × EtherNet/IP (10/100 Mbps, DLR-capable, embedded switch) |
| USB Ports | 2 × USB 2.0 Type-A (host) |
| SD Card Slot | 1 × SD/SDHC (up to 32 GB) |
| Supply Voltage | 24 VDC nominal (18–32 VDC operating range) |
| Power Consumption | ≤ 55 W typical at 24 VDC |
| Inrush Current | ≤ 10 A peak at 24 VDC cold start |
| Operating Temperature | 0 °C to +55 °C (32 °F to 131 °F) |
| Storage Temperature | −20 °C to +70 °C |
| Relative Humidity | 5–95% non-condensing |
| Enclosure Rating (front bezel) | NEMA 4, 4X, 12, 13 / IP65 |
| Vibration Resistance | 2 g, 10–500 Hz (IEC 60068-2-6) |
| Shock Resistance | 15 g, 11 ms half-sine (IEC 60068-2-27) |
| Panel Cutout Dimensions | 375.9 mm × 295.9 mm (W × H) |
| Overall Dimensions | 406.4 mm × 323.9 mm × 88.9 mm (W × H × D) |
| Weight | Approx. 4.5 kg |
| Certifications | UL 508, CE (EMC Directive 2014/30/EU), RCM, KC |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
Embedded DLR Switch Architecture: The dual EtherNet/IP ports on the 2711P-B15C22D9P are not two independent NICs — they share an embedded managed switch ASIC that implements the Device Level Ring (DLR) protocol per the EtherNet/IP specification. In a ring topology, the terminal participates in beacon-based fault detection with a default beacon interval of 400 µs. Upon detecting a link fault, the ring supervisor reconfigures the logical path in under 3 ms, maintaining uninterrupted tag polling without requiring a separate managed switch or redundant cabling run to the panel.
Resistive Touch Panel Signal Processing: The analog resistive overlay uses a four-wire matrix. Touch coordinates are resolved by measuring voltage ratios across the X and Y axes independently. The controller ASIC applies a median filter across a configurable sample window (default: 8 samples at 120 Hz) before reporting a touch event to the WES7 HID driver stack. This filtering approach rejects single-point noise spikes from arc welding or high-frequency VFD switching without introducing perceptible input latency for the operator.
Flash Storage Wear Leveling: The 4 GB industrial Flash module implements static and dynamic wear leveling at the firmware layer. Write amplification is managed by the onboard FTL (Flash Translation Layer), which distributes write cycles across all available erase blocks. Under typical HMI logging workloads (alarm history, audit trail writes at ≤ 1 write/second), the rated endurance exceeds 10 years of continuous operation before the P/E cycle limit is approached.
EMC Design: The steel rear chassis provides a continuous Faraday enclosure for the main PCB assembly. The front bezel frame is bonded to the chassis via conductive gaskets at the panel cutout interface, maintaining chassis ground continuity across the seam. Ferrite cores are integrated on the DC power input cable assembly to suppress common-mode noise in the 1–30 MHz band, consistent with EN 55011 Class A conducted emissions limits. The EtherNet/IP ports include transformer-coupled isolation rated at 1500 Vrms, protecting the internal logic from ground potential differences across long cable runs in industrial environments.
Thermal Management: The unit is fanless. Thermal dissipation relies on conduction through the rear chassis to the panel door. The Intel Atom E3827 processor implements hardware thermal throttling at a junction temperature of 105 °C, with a configurable OS-level thermal policy that reduces clock frequency in 25% steps before reaching the hardware limit. At the rated ambient of 55 °C with the terminal mounted in a sealed NEMA 4 enclosure, the thermal margin to throttle onset is approximately 18 °C under full CPU load.
System Integration Benefits
- Native FactoryTalk Diagnostics Integration: The terminal hosts a FactoryTalk Diagnostics client that subscribes to the controller’s diagnostic tag set. Fault codes, module status words, and I/O connection health are surfaced directly on operator faceplates without requiring a separate SCADA server, reducing diagnostic latency from minutes to seconds.
- Tag-Based Addressing with No Driver Configuration: EtherNet/IP implicit messaging uses controller tag names directly — no OPC server, no DDE bridge, no driver INI file. The FactoryTalk View ME project references controller tags by symbolic name, and the communication path is resolved at runtime by the Logix backplane tag database. This eliminates a class of integration errors common in legacy DDE-based HMI architectures.
- DLR Ring Redundancy Without Additional Hardware: Connecting the two Ethernet ports in a ring with other DLR-capable devices (e.g., 1756-EN2TR, PowerFlex 755 with 20-750-ENETR) provides network-level redundancy at the device layer. No managed switch, no STP configuration, no additional licensing — the DLR supervisor role can be assigned to any node in the ring.
- Alarm Management Compliant with ISA-18.2: FactoryTalk View ME on this platform supports alarm shelving, alarm suppression, and alarm state journaling to the onboard SD card or a network share. Alarm records include timestamp (synchronized via SNTP to the controller clock), operator ID, and state transition — meeting the audit trail requirements of ISA-18.2 and FDA 21 CFR Part 11 for regulated process industries.
- Remote Access via FactoryTalk View Studio: The terminal’s runtime can be monitored and the application updated remotely over EtherNet/IP using FactoryTalk View Studio’s remote download function. Application transfers are performed while the runtime is active, with a configurable switchover delay — minimizing planned downtime for HMI application updates.
- USB Peripheral Expansion: The two USB 2.0 host ports support barcode scanners, USB keyboards, USB storage for application backup/restore, and USB-to-serial adapters for legacy device integration. The WES7 USB stack enumerates standard HID and mass storage class devices without requiring custom drivers.
- Multi-Language Runtime Support: FactoryTalk View ME supports up to 20 language sets within a single application project. Language switching is operator-initiated at runtime via a configurable button object, with no application restart required. Character sets include Latin, Cyrillic, CJK (Chinese/Japanese/Korean), and Arabic (RTL rendering supported).
- Scalable Display Architecture: The 1024 × 768 XGA resolution provides sufficient pixel density for complex P&ID mimic displays, trend charts with 1-second resolution, and tabular data views simultaneously. The FactoryTalk View ME display server renders all graphic objects in a single-threaded GDI pipeline, ensuring deterministic screen refresh rates independent of tag update frequency.
Quality Assurance & Global Logistics
Every 2711P-B15C22D9P unit supplied by siemensplc.com is sourced directly from Rockwell Automation’s authorized distribution network or from verified surplus channels with full traceability documentation. Each unit undergoes incoming inspection that includes: power-on functional verification at 24 VDC, EtherNet/IP port link negotiation test, touch panel calibration verification, and visual inspection of the front bezel, rear chassis, and connector bodies for mechanical integrity. Units with evidence of rework, re-marking, or counterfeit indicators are rejected and quarantined.
Packaging follows IEC 60068-2-32 free-fall test requirements: the terminal is secured in a custom-cut EPE foam insert within a double-wall corrugated carton. Anti-static bags are used for all PCB-exposed surfaces. For international shipments, the carton is further wrapped in moisture-barrier film and labeled with handling instructions in English and the destination country’s language.
Logistics operations are based in Xiamen, China (Xiamen Gaoqi International Airport, IATA: XMN), with direct air freight access to major industrial hubs: Frankfurt (FRA), Chicago O’Hare (ORD), Dubai (DXB), Singapore (SIN), and Tokyo Narita (NRT). Standard air freight transit times are 3–5 business days to Europe and North America, 1–2 business days to Southeast Asia. DHL Express, FedEx International Priority, and UPS Worldwide Express are the primary carriers. All shipments include a commercial invoice, packing list, and certificate of origin. Export classification: EAR99 (no export license required for most destinations).
A 12-month warranty covers defects in materials and workmanship from the date of shipment. Warranty claims are processed within 5 business days of receipt of the returned unit. Advance replacement is available for customers with active service agreements.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.