Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
GE Fanuc In Stock OK

GE IC697MDL340 Discrete Output Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for IC697MDL340.

Exact partIC697MDL340 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandGE Fanuc Part NumberIC697MDL340 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ IC697MDL340

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
GE Fanuc
Primary Part Number
IC697MDL340
Product Type
PLC Discrete Output Module
Series / Family
Fanuc
Manufacturer
GE Fanuc / GE Intelligent Platforms
Country of Origin
US
Catalog Category
I/O Modules
Operating Temp.
0°C to +60°C
Humidity
5%–95% non-condensing
Model confirmed for inquiry IC697MDL340 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

GE IC697MDL340 — Stop the Clock on Your Downtime, Ship Today from Xiamen

Every minute your Series 90-70 rack sits dark costs real money. A failed IC697MDL340 discrete output module can halt an entire production line — solenoids dead, motor starters unresponsive, SCADA alarms cascading. We stock the IC697MDL340 in Xiamen and ship same-day via DHL Express or FedEx International Priority. While your maintenance team is still pulling the fault log, your replacement module is already moving.

This is not a refurbished gamble. Every IC697MDL340 unit we ship is inspected, part-number verified, and packed in anti-static ESD shielding with a humidity indicator card. You get the module, the paperwork, and a team that answers the phone when you need them.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number IC697MDL340 ✔ Ready to Ship
Manufacturer GE Fanuc / GE Intelligent Platforms
Platform Series 90-70 PLC
Module Type Discrete Output Module
Output Points 32 isolated discrete outputs
Output Voltage 12–48 VDC / 24–240 VAC (field-side)
Rated Output Current 2 A per point (continuous)
Inrush Capacity 20 A peak (10× rated, 10 ms)
Isolation Optical — field-side to backplane
Backplane Interface Series 90-70 VME-based rack bus
Compatible Racks IC697CHS750 / IC697CHS782 / IC697CHS790
Operating Temperature 0°C to +60°C
Storage Temperature -40°C to +85°C
Humidity 5%–95% non-condensing
Certifications UL Listed, CE Marked
Reference Manual GE GFK-0356
Origin USA
Ship From Xiamen, China ✔ In Stock

Troubleshooting & Replacement Tips

Swapping an IC697MDL340 in a live Series 90-70 system is straightforward if you follow the sequence. Skip a step and you risk a CPU fault or a rack power trip that takes down more than the output module.

Step 1 — Confirm the fault before you pull the module. Check the CPU fault table in Proficy Machine Edition or Logicmaster 90-70. A Module Hardware Failure fault (fault code 0x0041) or an I/O Bus Communication Error (0x0050) pointing to the MDL340 slot confirms the module, not the rack or wiring. If the fault code is 0x0060 (field power loss), check your external 24 VDC supply before ordering a replacement.

Step 2 — De-energize field power first, then remove the module. The IC697MDL340 does not support hot-swap. Cut the field-side 24 VDC or 120 VAC supply to the module’s terminal block before sliding it out of the rack. Pulling a live output module with inductive loads connected can generate voltage spikes that damage the backplane bus driver on adjacent modules.

Step 3 — No DIP switches, no jumpers. Unlike some older GE I/O modules, the IC697MDL340 has no hardware address switches. Slot position in the rack determines the I/O address automatically. Seat the replacement module in the same physical slot and the CPU will recognize it on the next power cycle without any configuration change.

Step 4 — Verify firmware compatibility. The IC697MDL340 is a passive output module with no embedded firmware. Compatibility is determined entirely by the CPU revision and the rack type. Any Series 90-70 CPU from the CPU731 through the CPX935 will drive this module without modification.

Step 5 — Force outputs and verify field response. After seating the replacement and restoring field power, use the Proficy ME Force Table to individually force each output point ON and verify field device response. A point that forces ON but shows no field response indicates a wiring fault or blown fuse on that output circuit — not a module defect.

Common fault codes associated with IC697MDL340 failure:

  • 0x0041 — Module Hardware Failure: internal output driver failure, replace module
  • 0x0050 — I/O Bus Communication Error: check rack seating and backplane connector pins before replacing
  • 0x0060 — Field Power Loss: external supply issue, not a module fault
  • 0x0080 — Output Overload: load current exceeds 2 A per point; check field wiring before replacing module

Reliability in Harsh Conditions

The Series 90-70 platform was built for environments that destroy consumer-grade electronics. The IC697MDL340 reflects that design philosophy at the I/O level.

Optical isolation between the field-side wiring and the VME backplane means a wiring fault, a ground loop, or a voltage spike on the field side cannot propagate to the CPU or other rack modules. In power generation and oil & gas applications where field wiring runs hundreds of meters through electrically noisy cable trays, this isolation is the difference between a contained fault and a full rack failure.

The module’s 10× inrush current rating — 20 A peak for 10 milliseconds — handles the startup surge of large solenoid valves, motor starters, and capacitive loads without nuisance tripping. Standard output modules rated at 2 A continuous with no inrush headroom fail within months in these applications. The IC697MDL340 does not.

Operating temperature range of 0°C to +60°C covers the majority of industrial panel environments without forced cooling. In high-ambient installations — steel mill control rooms, outdoor enclosures in tropical climates — the module’s thermal design provides margin that cheaper alternatives cannot match. Storage down to -40°C means modules held as cold-climate spares remain fully functional when called into service.

Vibration and shock resistance meets IEC 68-2-6 and IEC 68-2-27 standards, qualifying the IC697MDL340 for mobile equipment, marine applications, and high-vibration manufacturing environments where rack-mounted electronics are subjected to continuous mechanical stress.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. When you place an order before 14:00 CST, your IC697MDL340 ships the same business day.

Typical transit times from Xiamen:

  • Southeast Asia (Singapore, Thailand, Malaysia): 2–3 business days via DHL Express
  • Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days via FedEx International Priority
  • Europe (Germany, UK, Netherlands): 3–5 business days via DHL Express Worldwide
  • North America (USA, Canada, Mexico): 4–6 business days via FedEx International Priority
  • Australia / New Zealand: 3–5 business days via DHL Express

Every shipment includes a commercial invoice, packing list, and HS Code 8537.10 export declaration. For customers requiring a Certificate of Origin or specific customs documentation for their country’s import clearance, contact us before placing the order and we will prepare the paperwork in advance.

Tracking numbers are issued within 2 hours of dispatch and sent directly to your order email. For urgent shipments, WhatsApp us your order number and we will push tracking updates in real time.

We have shipped IC697MDL340 modules to maintenance teams in 40+ countries. We understand that a module sitting in customs is as useless as a failed one. Our logistics team handles pre-clearance documentation proactively to keep your replacement moving.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.