Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6AV6545-0BB15-2AX0 HMI Operator Panel

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6AV6545-0BB15-2AX0.

Exact part6AV6545-0BB15-2AX0 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6AV6545-0BB15-2AX0 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6AV6545-0BB15-2AX0

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6AV6545-0BB15-2AX0
Product Type
HMI Operator Panel
Series / Family
SIMATIC
Manufacturer
Siemens AG
Country of Origin
DE
Catalog Category
HMI Panels
Operating Temp.
0 °C to +50 °C
Model confirmed for inquiry 6AV6545-0BB15-2AX0 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

6AV6545-0BB15-2AX0 In Stock Now — Every Hour of Downtime Costs You Money

Your OP 73 panel just went dark. The line is stopped. Maintenance is standing by. You’ve already pulled the nameplate and confirmed the part number: 6AV6545-0BB15-2AX0. That’s exactly what we have on the shelf in Xiamen — tested, packed, and ready to move via DHL Express within hours of your order confirmation. We’ve handled enough plant-down calls to know that the difference between a 24-hour fix and a 72-hour nightmare is whether your supplier picks up the phone and actually ships the same day. We do.

⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number 6AV6545-0BB15-2AX0 ✅ Ready to Ship
Product Series SIMATIC HMI OP 73
Manufacturer Siemens AG
Display 3.8″ STN Monochrome LCD, 160 × 80 px
Keypad 18 keys — system + function keys
Communication MPI / PROFIBUS DP (RS-485)
Supply Voltage 24 V DC (20.4–28.8 V)
Power Consumption ≈ 3.5 W
Operating Temperature 0 °C to +50 °C
Storage Temperature −20 °C to +60 °C
Front Panel Protection IP65 (IEC 60529)
Mounting Cut-out 138 × 102 mm (portrait or landscape)
Configuration Tool WinCC flexible Compact / STEP 7 Micro/WIN
User Memory 64 KB
Dimensions (W×H×D) ≈ 144 × 108 × 45 mm
Weight ≈ 0.35 kg
Certifications CE, UL/cUL, RoHS, PROFIBUS DP (IEC 61158)
Compatible PLCs S7-200, S7-300, S7-400 via MPI/PROFIBUS DP
Ship-from Location Xiamen, China ✅ Same-Day Dispatch Available

Troubleshooting & Replacement Tips

Ten years of field calls on OP 73 panels teach you the same failure patterns over and over. Here’s what to check before you pull the trigger on a replacement — and what to do when you do replace it.

Common Fault Codes & Root Causes

  • “No Connection to PLC” on startup: 90% of the time this is a dead MPI bus connector or a corroded RS-485 termination resistor. Swap the bus connector first (6ES7972-0BB52-0XA0) before condemning the panel. If the fault persists after connector swap, the OP 73’s MPI ASIC has likely failed — replace the panel.
  • Blank/white display, panel still responds to keys: Backlight inverter failure. The STN panel itself is fine. Unfortunately the OP 73 backlight is not field-replaceable as a discrete component — full panel swap is the correct repair path.
  • Display shows garbled characters or partial rows: LCD ribbon cable delamination, typically caused by repeated thermal cycling in high-ambient environments. Not repairable in the field. Replace the unit.
  • Panel powers on but WinCC flexible cannot download project: Check the PC–MPI adapter driver version. WinCC flexible Compact requires the correct USB driver for the 6GK1571-0BA00-0AA0 adapter. Also verify the MPI address on the panel matches the address configured in your WinCC project (default: node 1).
  • “Transfer” mode not accessible: Hold the ESC key during power-up to force the panel into transfer mode. This bypasses a corrupted project that prevents normal boot.
  • Function keys unresponsive after replacement: The OP 73 does not have DIP switches or hardware address selectors — MPI node address is set via the panel’s startup menu (Settings → Interface → MPI Address). Set this before downloading your project. Default MPI address is 1; if your bus already has a node 1 device, you will get a bus conflict.

Replacement Checklist — Do This Before You Power Up the New Panel

  1. Confirm 24 V DC supply is within spec (20.4–28.8 V). Overvoltage is the leading cause of premature OP 73 failure in the field.
  2. Inspect the MPI/PROFIBUS cable for shield continuity. A floating shield on a long bus run will cause intermittent communication faults that look like panel hardware failures.
  3. Set the MPI node address via the startup menu before connecting to the bus. Avoid address conflicts with the CPU (typically node 2) and PG/PC (typically node 0).
  4. Verify WinCC flexible project version compatibility. Projects built in WinCC flexible 2008 SP3 or earlier may require a migration step before downloading to a replacement panel with newer firmware.
  5. After download, cycle power once and confirm all alarm screens and recipe pages render correctly before handing back to operations.

Reliability in Harsh Conditions

The OP 73 was engineered for the factory floor, not the office. The IP65-rated front bezel keeps out metal dust, coolant mist, and direct water spray — the kind of environment that kills consumer-grade touchscreens in weeks. The STN monochrome display has no active backlight matrix to fail under vibration; it’s a passive panel that tolerates the constant 5–50 Hz mechanical vibration typical of press lines and compressor rooms far better than TFT color panels of the same era.

Operating range of 0–50 °C covers the vast majority of industrial cabinet interiors, even in summer in Southeast Asia or the Middle East where ambient temperatures push 40 °C and cabinet internal temps can run 10 °C above ambient. The −20 °C storage rating means units can be warehoused in unheated facilities without risk of LCD crystal damage.

The 24 V DC power input includes a wide tolerance band (20.4–28.8 V) that absorbs the voltage sags common on long DC distribution runs in large panels. At 3.5 W draw, it imposes negligible load on even a modest SITOP supply, leaving headroom for the rest of your I/O cards and field devices.

Every unit we ship from Xiamen is visually inspected against Siemens reference markings, power-on tested for display function, and packed in anti-static foam with desiccant. We don’t drop-ship from unknown secondary sources. If it leaves our warehouse, it has been through our hands.

Global Express Logistics

Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL Express and FedEx International Priority connections to major industrial hubs worldwide. Here’s how a typical urgent order moves:

  • Order confirmed before 14:00 CST: Same-day dispatch. DHL Express waybill generated, unit collected by courier same afternoon.
  • Transit to Europe (Germany, Poland, Italy, Netherlands): 2–3 business days door-to-door via DHL Express Worldwide.
  • Transit to North America (USA, Canada, Mexico): 2–4 business days via FedEx International Priority.
  • Transit to Southeast Asia (Thailand, Vietnam, Indonesia, Malaysia): 1–2 business days via DHL Express.
  • Transit to Middle East (UAE, Saudi Arabia, Qatar): 2–3 business days via DHL Express.
  • Transit to South America (Brazil, Chile, Colombia): 4–6 business days via FedEx International Priority.

All shipments include a commercial invoice, packing list, and HS code declaration (8537.10) as standard — no delays at customs from missing paperwork. For orders requiring an ATA Carnet, end-user certificate, or specific country-of-origin documentation, contact us before ordering and we will prepare the correct set.

Tracking numbers are sent via email and WhatsApp within 2 hours of dispatch. We monitor shipments actively and will proactively notify you of any carrier delays — you won’t be chasing us for updates while your line sits idle.

Contact Information

📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.